메뉴 건너뛰기




Volumn 289, Issue 1-2, 1999, Pages 145-158

An enzyme thermistor-based assay for total and free cholesterol

Author keywords

Bile; Enzyme thermistor; Flow injection analysis; Free cholesterol; Gall stones; HDL C; LDL C; Serum; Total cholesterol

Indexed keywords

CATALASE; CHOLESTEROL; CHOLESTEROL ESTER; CHOLESTEROL ESTERASE; CHOLESTEROL OXIDASE; HIGH DENSITY LIPOPROTEIN CHOLESTEROL; LOW DENSITY LIPOPROTEIN CHOLESTEROL;

EID: 0032720476     PISSN: 00098981     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0009-8981(99)00174-6     Document Type: Article
Times cited : (27)

References (23)
  • 1
    • 0031851350 scopus 로고    scopus 로고
    • Assessment of current national cholesterol education program guidelines for total cholesterol, triglyceride. HDL-C and LDL-C measurements
    • Caudill SP, Cooper GR, Smith SJ, Myers GL. Assessment of current national cholesterol education program guidelines for total cholesterol, triglyceride. HDL-C and LDL-C measurements. Clin Chem 1998;44(8):1650-8.
    • (1998) Clin Chem , vol.44 , Issue.8 , pp. 1650-1658
    • Caudill, S.P.1    Cooper, G.R.2    Smith, S.J.3    Myers, G.L.4
  • 2
    • 0031254720 scopus 로고    scopus 로고
    • In search of the ideal measure of high-density lipoprotein
    • Reed RG. In search of the ideal measure of high-density lipoprotein. Clin Chem 1997;43(10):1809-10.
    • (1997) Clin Chem , vol.43 , Issue.10 , pp. 1809-1810
    • Reed, R.G.1
  • 3
    • 0030962227 scopus 로고    scopus 로고
    • Comparison of two assays for measuring LDL cholesterol
    • Maitra A, Hirany SV, Jialal I. Comparison of two assays for measuring LDL cholesterol. Clin Chem 1997;43(6):1040-7.
    • (1997) Clin Chem , vol.43 , Issue.6 , pp. 1040-1047
    • Maitra, A.1    Hirany, S.V.2    Jialal, I.3
  • 5
    • 0345537806 scopus 로고    scopus 로고
    • Freehold, NJ 07728: Worthington Biochemical Corporation
    • Worthington. Manual: enzymes and related biochemicals, Freehold, NJ 07728: Worthington Biochemical Corporation, 1999.
    • (1999) Manual: Enzymes and Related Biochemicals
  • 6
    • 0345537805 scopus 로고    scopus 로고
    • Bombay, India: Accurex Biomedical Pvt. Ltd
    • Accurex. Total cholesterol kit, Bombay, India: Accurex Biomedical Pvt. Ltd, 1999.
    • (1999) Total Cholesterol Kit
  • 9
    • 84943093058 scopus 로고
    • Enzyme electrode with collagen immobilized cholesterol oxidase for the microdetermination of free cholesterol
    • Bertrand C, Coulet PR, Gautheron DC. Enzyme electrode with collagen immobilized cholesterol oxidase for the microdetermination of free cholesterol. Anal Lett 1979;12:1477-88.
    • (1979) Anal Lett , vol.12 , pp. 1477-1488
    • Bertrand, C.1    Coulet, P.R.2    Gautheron, D.C.3
  • 10
    • 0026848794 scopus 로고
    • Colorimetric determination of free and total cholesterol by flow injection analysis with a fiber optic detector
    • Krug A, Suleiman AA, Guilbault GG, Kellner R. Colorimetric determination of free and total cholesterol by flow injection analysis with a fiber optic detector. Enzym Microb Technol 1992;14:313-6.
    • (1992) Enzym Microb Technol , vol.14 , pp. 313-316
    • Krug, A.1    Suleiman, A.A.2    Guilbault, G.G.3    Kellner, R.4
  • 11
    • 84951400121 scopus 로고
    • An organic phase enzyme electrode for cholesterol
    • Hall GF, Turner APF. An organic phase enzyme electrode for cholesterol. Anal Lett 1991;24(8):1375-88.
    • (1991) Anal Lett , vol.24 , Issue.8 , pp. 1375-1388
    • Hall, G.F.1    Turner, A.P.F.2
  • 12
    • 0019965451 scopus 로고
    • Direct determination of lipoprotein cholesterol distribution with micro-scale affinity chromatography columns
    • Bentzen CL, Acuff KJ, Marechal B, Rosenthal MA, Volk ME. Direct determination of lipoprotein cholesterol distribution with micro-scale affinity chromatography columns. Clin Chem 1982;28(7):1451-6.
    • (1982) Clin Chem , vol.28 , Issue.7 , pp. 1451-1456
    • Bentzen, C.L.1    Acuff, K.J.2    Marechal, B.3    Rosenthal, M.A.4    Volk, M.E.5
  • 13
    • 0030900029 scopus 로고    scopus 로고
    • Calculation of LDL cholesterol by using apolipoprotein B for classification of non-chylomicronemic dyslipemia
    • Planella T, Cortes M, Martinez-Bru C, Gonzalez-Satre F, Ordonez-Lianos B. Calculation of LDL cholesterol by using apolipoprotein B for classification of non-chylomicronemic dyslipemia. J Clin Chem 1997;435:808-15.
    • (1997) J Clin Chem , vol.435 , pp. 808-815
    • Planella, T.1    Cortes, M.2    Martinez-Bru, C.3    Gonzalez-Satre, F.4    Ordonez-Lianos, B.5
  • 14
    • 9844246438 scopus 로고    scopus 로고
    • Multicenter evaluation of a homogeneous assay for HDL-C without sample pretreatment
    • Nauck M, Marz W, Jarausch J et al. Multicenter evaluation of a homogeneous assay for HDL-C without sample pretreatment. Clin Chem 1997;43(9):1662-9.
    • (1997) Clin Chem , vol.43 , Issue.9 , pp. 1662-1669
    • Nauck, M.1    Marz, W.2    Jarausch, J.3
  • 15
    • 0030744777 scopus 로고    scopus 로고
    • Suitability of chemical in vitro models to investigate LDL oxidation: Study with different initiating conditions in native and alpha-tocopherol supplemented LDL
    • Seccia M, Albano E, Bellomu G. Suitability of chemical in vitro models to investigate LDL oxidation: Study with different initiating conditions in native and alpha-tocopherol supplemented LDL. Clin Chem 1997;43(8):1436-41.
    • (1997) Clin Chem , vol.43 , Issue.8 , pp. 1436-1441
    • Seccia, M.1    Albano, E.2    Bellomu, G.3
  • 17
    • 0031589688 scopus 로고    scopus 로고
    • Evaluation of a miniaturized thermal biosensor for the determination of glucose in whole blood
    • Harborn U, Xie B, Venkatesh R, Danielsson B. Evaluation of a miniaturized thermal biosensor for the determination of glucose in whole blood. Clin Chim Acta 1997;267:225-37.
    • (1997) Clin Chim Acta , vol.267 , pp. 225-237
    • Harborn, U.1    Xie, B.2    Venkatesh, R.3    Danielsson, B.4
  • 18
    • 0028670525 scopus 로고
    • Urea and lactate determined in 1-μl whole-blood samples with a miniaturized thermal biosensor
    • Xie B, Harborn U, Mecklenburg M, Danielsson B. Urea and lactate determined in 1-μl whole-blood samples with a miniaturized thermal biosensor. Clin Chem 1994;40:2282-7.
    • (1994) Clin Chem , vol.40 , pp. 2282-2287
    • Xie, B.1    Harborn, U.2    Mecklenburg, M.3    Danielsson, B.4
  • 19
    • 0029168799 scopus 로고
    • Development of an integrated thermal biosensor for the simultaneous determination of multiple analytes
    • Xie B, Mecklenburg M, Danielsson B, Öhman O, Norlin P, Winquist F. Development of an integrated thermal biosensor for the simultaneous determination of multiple analytes. Analyst 1995;120:155-60.
    • (1995) Analyst , vol.120 , pp. 155-160
    • Xie, B.1    Mecklenburg, M.2    Danielsson, B.3    Öhman, O.4    Norlin, P.5    Winquist, F.6
  • 20
    • 0014215758 scopus 로고
    • Chemical coupling of peptides and proteins to polysaccharides by means of cyanogen halides
    • Axen R, Porath J, Ernback S. Chemical coupling of peptides and proteins to polysaccharides by means of cyanogen halides. Nature 1967;214:1302-4.
    • (1967) Nature , vol.214 , pp. 1302-1304
    • Axen, R.1    Porath, J.2    Ernback, S.3
  • 21
    • 0017267831 scopus 로고
    • Covalent coupling methods for inorganic support materials
    • Weetall HH. Covalent coupling methods for inorganic support materials. Methods Enzymol 1976;44:134-48.
    • (1976) Methods Enzymol , vol.44 , pp. 134-148
    • Weetall, H.H.1
  • 22
    • 0342842492 scopus 로고
    • Enzyme thermistor assay of cholesterol, glucose, lactose and uric acid in standard solutions as well as in biological samples
    • Mattiasson B, Danielsson B, Mosbach K. Enzyme thermistor assay of cholesterol, glucose, lactose and uric acid in standard solutions as well as in biological samples. Anal Lett 1976;9:217-21.
    • (1976) Anal Lett , vol.9 , pp. 217-221
    • Mattiasson, B.1    Danielsson, B.2    Mosbach, K.3
  • 23
    • 0004437349 scopus 로고    scopus 로고
    • Simultaneous determination of glucose, lactate, urea and penicillin in mixed samples using an integrated thermal biosensor
    • Xie B, Mecklenburg M, Dzgoev A, Danielsson B. Simultaneous determination of glucose, lactate, urea and penicillin in mixed samples using an integrated thermal biosensor. Anal Methods Instrum μTAS 1996;1(Special Issue):95-9.
    • (1996) Anal Methods Instrum ΜTAS , vol.1 , Issue.SPEC. ISSUE , pp. 95-99
    • Xie, B.1    Mecklenburg, M.2    Dzgoev, A.3    Danielsson, B.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.