Volumn 267, Issue 2, 1997, Pages 225-237

Evaluation of a miniaturized thermal biosensor for the determination of glucose in whole blood

Author keywords

Biosensor; Calibration aspects; Calorimetric; Diabetes; Enzyme thermistor; Flow injection analysis; Glucose oxidase; Thermal

Indexed keywords

ASCORBIC ACID; CATALASE; GLUCOSE; GLUCOSE OXIDASE; PARACETAMOL; URIC ACID;

EID: 0031589688     PISSN: 00098981     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0009-8981(97)00151-4     Document Type: Article
Times cited : (40)

References (20)
  • 1
    • 0345106266 scopus 로고
    • What is a biosensor?
    • In: Blum J, Coulet PR, editors. New York: Marcel Dekker, York
    • Coulet PR. What is a biosensor? In: Blum J, Coulet PR, editors. Biosensors principles and applications. New York: Marcel Dekker, 1991. York.
    • (1991) Biosensors Principles and Applications
    • Coulet, P.R.1
  • 2
    • 0025478282 scopus 로고
    • Calorimetric biosensors
    • Danielsson B. Calorimetric biosensors. J Biotechnol. 15:1990;187-200.
    • (1990) J Biotechnol , vol.15 , pp. 187-200
    • Danielsson, B.1
  • 3
    • 0017668472 scopus 로고
    • Enzyme thermistor determination of glucose in serum using immobilized glucose oxidase
    • Danielsson B., Gadd K., Mattiasson B., Mosbach K. Enzyme thermistor determination of glucose in serum using immobilized glucose oxidase. Clin Chim Acta. 81:1977;163-175.
    • (1977) Clin Chim Acta , vol.81 , pp. 163-175
    • Danielsson, B.1    Gadd, K.2    Mattiasson, B.3    Mosbach, K.4
  • 4
    • 0027313249 scopus 로고
    • Industrial on-line monitoring of penicillin V using a split-flow modified thermal biosensor
    • Rank M., Danielsson B., Gram J. Industrial on-line monitoring of penicillin V using a split-flow modified thermal biosensor. Anal Chim Acta. 281:1993;521-526.
    • (1993) Anal Chim Acta , vol.281 , pp. 521-526
    • Rank, M.1    Danielsson, B.2    Gram, J.3
  • 6
    • 0027647443 scopus 로고
    • Fast determinations of whole blood glucose with a calorimetric micro-biosensor
    • Xie B., Hedberg U., Danielsson B. Fast determinations of whole blood glucose with a calorimetric micro-biosensor. Sens and Act B. 15-16:1993;141-144.
    • (1993) Sens and Act B , vol.1516 , pp. 141-144
    • Xie, B.1    Hedberg, U.2    Danielsson, B.3
  • 7
    • 0345080475 scopus 로고
    • Biosensors for diabetes mellitus
    • In: Wise DL, editor. Boston; Butterworth
    • Pickup JC. Biosensors for diabetes mellitus. In: Wise DL, editor. Applied Biosensors. Boston; Butterworth, 1989.
    • (1989) Applied Biosensors
    • Pickup, J.C.1
  • 8
    • 84908830001 scopus 로고
    • Can continuous glucose monitoring be used for the treatment of diabetes
    • Reach G., Wilson G.S. Can continuous glucose monitoring be used for the treatment of diabetes. Anal Chem. 6:1992;381-386.
    • (1992) Anal Chem , vol.6 , pp. 381-386
    • Reach, G.1    Wilson, G.S.2
  • 9
    • 0028670525 scopus 로고
    • Urea and lactate determined in 1-μL whole-blood samples with a miniaturized thermal biosensor
    • Xie B., Harborn U., Mecklenburg M., Danielsson B. Urea and lactate determined in 1-μL whole-blood samples with a miniaturized thermal biosensor. Clin Chem. 40:1994;2282-2287.
    • (1994) Clin Chem , vol.40 , pp. 2282-2287
    • Xie, B.1    Harborn, U.2    Mecklenburg, M.3    Danielsson, B.4
  • 10
    • 0017267831 scopus 로고
    • Covalent coupling methods for inorganic support materials
    • Weetall H.H. Covalent coupling methods for inorganic support materials. Methods Enzymol. 44:1976;139-141.
    • (1976) Methods Enzymol. , vol.44 , pp. 139-141
    • Weetall, H.H.1
  • 11
    • 0022883359 scopus 로고
    • Laboratory assessment of three new monitors of blood glucose: Accuchek II, Glukometer II and Glucoscan 2000
    • Brooks K.E., Rawal N., Henderson A. Laboratory assessment of three new monitors of blood glucose: Accuchek II, Glukometer II and Glucoscan 2000. Clin Chem. 32:1986;2195-2200.
    • (1986) Clin Chem , vol.32 , pp. 2195-2200
    • Brooks, K.E.1    Rawal, N.2    Henderson, A.3
  • 12
    • 0027143423 scopus 로고
    • Laboratory assessment of five glucose meters designed for self-monitoring of blood glucose concentration
    • Devreese K., Leroux-Roels G. Laboratory assessment of five glucose meters designed for self-monitoring of blood glucose concentration. Eur J Clin Chem Clin Biochem. 31:1993;29-37.
    • (1993) Eur J Clin Chem Clin Biochem , vol.31 , pp. 29-37
    • Devreese, K.1    Leroux-Roels, G.2
  • 14
    • 0003072603 scopus 로고
    • Determination of glucose in blood using glucose oxidase with an alternative oxygen receptor
    • Trinder P. Determination of glucose in blood using glucose oxidase with an alternative oxygen receptor. Ann Clin Biochem. 6:1969;24-27.
    • (1969) Ann Clin Biochem , vol.6 , pp. 24-27
    • Trinder, P.1
  • 16
    • 0027650815 scopus 로고
    • Performance of subcutaneously implanted needle-type glucose sensors employing a novel trilayer coating
    • Moussy F., Harrison D.J., O'Brien D.W., Rajotte R.V. Performance of subcutaneously implanted needle-type glucose sensors employing a novel trilayer coating. Anal Chem. 65:1993;2072-2077.
    • (1993) Anal Chem , vol.65 , pp. 2072-2077
    • Moussy, F.1    Harrison, D.J.2    O'Brien, D.W.3    Rajotte, R.V.4
  • 18
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland J.M., Altman D.G. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 8:1986;307-311.
    • (1986) Lancet , vol.8 , pp. 307-311
    • Bland, J.M.1    Altman, D.G.2
  • 19
    • 0345511996 scopus 로고
    • The distribution of sugar in normal human blood
    • Somogyi M. The distribution of sugar in normal human blood. J Biol Chem. 78:1928;117-127.
    • (1928) J Biol Chem , vol.78 , pp. 117-127
    • Somogyi, M.1
  • 20
    • 0025306522 scopus 로고
    • What is blood glucose: Can it be measured?
    • Burrin J.M., Alberti K.G.M.M. What is blood glucose: Can it be measured? Diabetic Med. 7:1990;199-206.
    • (1990) Diabetic Med , vol.7 , pp. 199-206
    • Burrin, J.M.1    Alberti, K.G.M.M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.