메뉴 건너뛰기




Volumn 35, Issue 1, 1988, Pages 757-761

Post-injection transmission attenuation measurements for PET

Author keywords

[No Author keywords available]

Indexed keywords

BIOMEDICAL ENGINEERING - COMPUTERIZED TOMOGRAPHY; SIGNAL PROCESSING;

EID: 0000578225     PISSN: 00189499     EISSN: 15581578     Source Type: Journal    
DOI: 10.1109/23.12827     Document Type: Article
Times cited : (43)

References (8)
  • 2
    • 0020048935 scopus 로고
    • Determination of object contour from projections for attenuation correction in cranial positron emission tomography
    • Bergstrom M, Litton J, Eriksson L, et al: Determination of object contour from projections for attenuation correction in cranial positron emission tomography. J Comput Assist Tomogr, 6:365-372, 1982.
    • (1982) J Comput Assist Tomogr , vol.6 , pp. 365-372
    • Bergstrom, M.1    Litton, J.2    Eriksson, L.3
  • 3
    • 0022667556 scopus 로고
    • An edge detection algorithm for attenuation correction in emission CT
    • Tomitami T. An edge detection algorithm for attenuation correction in emission CT. IEEE Trans Nucl Sci, NS-34:309-312, 1987.
    • (1987) IEEE Trans Nucl Sci. , vol.NS-34 , pp. 309-312
    • Tomitami, T.1
  • 4
    • 0012922027 scopus 로고
    • The orbiting rod source: Improving performance in PET transmission correction scans
    • New York, Society of Nuclear Medicine
    • Carroll LR, Kretz P, Orcutt G: The orbiting rod source: Improving performance in PET transmission correction scans. In Emission Computed Tomography: Current Trends. New York, Society of Nuclear Medicine, 1983, PP 235–247.
    • (1983) Emission Computed Tomography: Current Trends , pp. 235-247
    • Carroll, L.R.1    Kretz, P.2    Orcutt, G.3
  • 7
    • 0020660172 scopus 로고
    • Corrections for scattered radiation in a ring detector positron camera by integral transformation of the projections
    • Bergstrom M, Eriksson L, Bohm C, et al: Corrections for scattered radiation in a ring detector positron camera by integral transformation of the projections. J Comput Assist Tomogr, 7:42-50, 1983.
    • (1983) J Comput Assist Tomogr , vol.7 , pp. 42-50
    • Bergstrom, M.1    Eriksson, L.2    Bohm, C.3
  • 8
    • 0022602930 scopus 로고
    • A technique for the correction of scattered radiation in a PET system using time-of-flight information
    • Bendriem B, Soussaline F, Campagnolo R, et al: A technique for the correction of scattered radiation in a PET system using time-of-flight information. J Comput Assist Tomogr, 10:287-295, 1986.
    • (1986) J Comput Assist Tomogr , vol.10 , pp. 287-295
    • Bendriem, B.1    Soussaline, F.2    Campagnolo, R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.