메뉴 건너뛰기




Volumn 17, Issue 6, 1998, Pages 1073-1080

An evaluation of exact and approximate 3-D reconstruction algorithms for a high- resolution, small-animal PET scanner

Author keywords

Image reconstruction; Positron emission tomography (PET); Small animal pet scanner; Three dimensional (3 D) reconstruction

Indexed keywords

ALGORITHMS; COMPUTER SIMULATION; IMAGE RECONSTRUCTION; POSITRON EMISSION TOMOGRAPHY; SCANNING; THREE DIMENSIONAL COMPUTER GRAPHICS;

EID: 0032216620     PISSN: 02780062     EISSN: None     Source Type: Journal    
DOI: 10.1109/42.746722     Document Type: Article
Times cited : (17)

References (19)
  • 1
    • 0028486732 scopus 로고    scopus 로고
    • Are animal scanners really necessary for PET?, vol. 35, pp. 1396-1397, 1994.
    • R. Hichwa, "Are animal scanners really necessary for PET?," J. Nucl. Med.. vol. 35, pp. 1396-1397, 1994.
    • J. Nucl. Med..
    • Hichwa, R.1
  • 4
    • 0029428610 scopus 로고    scopus 로고
    • A high resolution PET scanner based on avalanche photodiode detectors for animal studies, in 1995 IEEE Engineering in Medicine and Biology 17th Annu. Conf. and 21 Canadian Medical and Biological Engineering Conf., vol. 1, pp. 525-526, 1997.
    • R. Lecomte, J. Cadorette, S. Rodrigue, M. Bentourkia, D. Rouleau, R. Yao, and P. Msaki, "A high resolution PET scanner based on avalanche photodiode detectors for animal studies," in Proc. 1995 IEEE Engineering in Medicine and Biology 17th Annu. Conf. and 21 Canadian Medical and Biological Engineering Conf., vol. 1, pp. 525-526, 1997.
    • Proc.
    • Lecomte, R.1    Cadorette, J.2    Rodrigue, S.3    Bentourkia, M.4    Rouleau, D.5    Yao, R.6    Msaki, P.7
  • 7
    • 0031981253 scopus 로고    scopus 로고
    • High resolution 3D Bayesian image reconstruction using the microPET small animal scanner, vol. 43, pp. 1001-1013, 1998.
    • J. Qi, R. M. Leahy, S. R. Cherry, A. Chatziioannou, and T. H. Farquhar, "High resolution 3D Bayesian image reconstruction using the microPET small animal scanner," Phys. Med. Biol., vol. 43, pp. 1001-1013, 1998.
    • Phys. Med. Biol.
    • Qi, J.1    Leahy, R.M.2    Cherry, S.R.3    Chatziioannou, A.4    Farquhar, T.H.5
  • 9
    • 0024610693 scopus 로고    scopus 로고
    • Analytic 3D image reconstruction using all detected events, vol. 36, pp. 964-968, 1989.
    • P. E. Kinahan and J. G. Rogers, "Analytic 3D image reconstruction using all detected events," IEEE Trans. Nucl. Sci., vol. 36, pp. 964-968, 1989.
    • IEEE Trans. Nucl. Sci.
    • Kinahan, P.E.1    Rogers, J.G.2
  • 11
    • 0023640412 scopus 로고    scopus 로고
    • Treatment of axial data in three-dimensional PET,/ vol. 28, pp. 1717-1724, 1987.
    • M. E. Daube-Witherspoon and G. Muehllehner, "Treatment of axial data in three-dimensional PET,"/ Nucl. Med., vol. 28, pp. 1717-1724, 1987.
    • Nucl. Med.
    • Daube-Witherspoon, M.E.1    Muehllehner, G.2
  • 13
    • 0028184998 scopus 로고    scopus 로고
    • Investigating the effect of angular mashing of PET sinogram data on reconstructed images, in 1993 vol. 2, pp. 1213-1216, 1993.
    • H. P. Gadagkar and M. Casey, "Investigating the effect of angular mashing of PET sinogram data on reconstructed images," in 1993 IEEE Conf. Rec. Nuclear Science Symp. and Medical Imaging Conf., vol. 2, pp. 1213-1216, 1993.
    • IEEE Conf. Rec. Nuclear Science Symp. and Medical Imaging Conf.
    • Gadagkar, H.P.1    Casey, M.2
  • 14
    • 85034164941 scopus 로고    scopus 로고
    • Investigation of resolution and artifacts in 3D PET due to data set reduction techniques, vol. 37, p. 73P, 1996.
    • T. H. Farquhar, Y.-C. Tai, E. J. Huffman, M. Dahlbom, and S. R. Cherry, "Investigation of resolution and artifacts in 3D PET due to data set reduction techniques," J. Nucl. Med., vol. 37, p. 73P, 1996.
    • J. Nucl. Med.
    • Farquhar, T.H.1    Tai, Y.-C.2    Huffman, E.J.3    Dahlbom, M.4    Cherry, S.R.5
  • 17
    • 0026522954 scopus 로고    scopus 로고
    • Design features and performance of a PET system for animal research, vol. 33, pp. 595-604, 1992.
    • P. D. Cutler, S. R. Cherry, E. J. Huffman, W. M. Digby, and M. E. Phelps, "Design features and performance of a PET system for animal research," J. Nucl. Med., vol. 33, pp. 595-604, 1992.
    • J. Nucl. Med.
    • Cutler, P.D.1    Cherry, S.R.2    Huffman, E.J.3    Digby, W.M.4    Phelps, M.E.5
  • 18
    • 0026582130 scopus 로고    scopus 로고
    • Evaluation of a 3D reconstruction algorithm for multi-slice PET scanners, vol. 37, pp. 779-790, 1992.
    • S. R. Cherry, M. Dahlbom, and E. J. Huffman, "Evaluation of a 3D reconstruction algorithm for multi-slice PET scanners," Phys. Med. Biol, vol. 37, pp. 779-790, 1992.
    • Phys. Med. Biol
    • Cherry, S.R.1    Dahlbom, M.2    Huffman, E.J.3
  • 19
    • 0028286963 scopus 로고    scopus 로고
    • Figures of merit for comparing reconstruction algorithms with a volume-imaging PET scanner, vol. 39, pp. 631-642, 1994.
    • P. E. Kinahan and J. S. Karp, "Figures of merit for comparing reconstruction algorithms with a volume-imaging PET scanner," Phys. Med. Biol., vol. 39, pp. 631-642, 1994.
    • Phys. Med. Biol.
    • Kinahan, P.E.1    Karp, J.S.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.