메뉴 건너뛰기




Volumn 17, Issue 6, 1998, Pages 979-985

Evaluation of the ECAT EXACT HR+ 3-D PET scanner in H215O brain activation studies: Dose fractionation strategies for rCBF and signal enhancing protocols

Author keywords

Activation studies; ECAT HR+; H215o; PET

Indexed keywords

BRAIN; FUNCTIONAL NEURAL STIMULATION; HEMODYNAMICS; NEUROPHYSIOLOGY; POSITRON EMISSION TOMOGRAPHY; SUBJECTIVE TESTING;

EID: 0032216611     PISSN: 02780062     EISSN: None     Source Type: Journal    
DOI: 10.1109/42.746630     Document Type: Article
Times cited : (15)

References (28)
  • 1
    • 0027196257 scopus 로고    scopus 로고
    • Improved detection of focal cerebral blood flow changes using three-dimensional positron emission tomography, vol. 13, no. 4, pp. 630-8, 1993.
    • S. R. Cherry, R. P. Woods, E. J. Huffman, and J. C. Mazziotta, "Improved detection of focal cerebral blood flow changes using three-dimensional positron emission tomography," J. Cereb. Blood Flow Metab., vol. 13, no. 4, pp. 630-8, 1993.
    • J. Cereb. Blood Flow Metab.
    • Cherry, S.R.1    Woods, R.P.2    Huffman, E.J.3    Mazziotta, J.C.4
  • 2
    • 0028197239 scopus 로고    scopus 로고
    • Functional neuroanatomy of the human brain: Positron emission tomography-A new neuroanatomical technique, vol. 184, pp. 211-225, 1994.
    • R. S. Frackowiak and K. J. Friston, "Functional neuroanatomy of the human brain: Positron emission tomography-A new neuroanatomical technique," J. Anat., vol. 184, pp. 211-225, 1994.
    • J. Anat.
    • Frackowiak, R.S.1    Friston, K.J.2
  • 3
    • 0021030757 scopus 로고    scopus 로고
    • Brain blood flow measured with intravenous H215O. (I) Theory and error analysis, vol. 24, pp. 782-789, 1983.
    • P. Herscovitch, J. Markham, and M. E. Raichle, "Brain blood flow measured with intravenous H215O. (I) Theory and error analysis," J. Nucl. Med.. vol. 24, pp. 782-789, 1983.
    • J. Nucl. Med..
    • Herscovitch, P.1    Markham, J.2    Raichle, M.E.3
  • 4
    • 0021084822 scopus 로고    scopus 로고
    • Brain blood flow measured with intravenous H215O. II. Implementation and validation, vol. 24, pp. 790-798, 1983.
    • M. E. Raichle, W. R. W. Martin, P. Herscovitch, M. A. Mintun, J. Markham, "Brain blood flow measured with intravenous H215O. II. Implementation and validation," J. Nucl. Med., vol. 24, pp. 790-798, 1983.
    • J. Nucl. Med.
    • Raichle, M.E.1    Martin, W.R.W.2    Herscovitch, P.3    Mintun, M.A.4    Markham, J.5
  • 5
    • 0026008833 scopus 로고    scopus 로고
    • Optimal scan time of oxygen-15-labeled water injection method for measurements of cerebral blood flow, vol. 32, pp. 1931-1934, 1991.
    • I. Kanno, H. lida, S. Miura, and M. Murakami, "Optimal scan time of oxygen-15-labeled water injection method for measurements of cerebral blood flow," J. Nucl. Med.. vol. 32, pp. 1931-1934, 1991.
    • J. Nucl. Med..
    • Kanno, I.1    Lida, H.2    Miura, S.3    Murakami, M.4
  • 6
    • 33747509930 scopus 로고    scopus 로고
    • Length of PET data acquisition inversely affects ability to detect focal areas of brain activation, vol. 9, Suppl-l:S349, 1989.
    • M. A. Mintun, M. E. Raichle, and R. P. Quarles, "Length of PET data acquisition inversely affects ability to detect focal areas of brain activation," J. Cereb. Blood Flow Metab.. vol. 9, Suppl-l:S349, 1989.
    • J. Cereb. Blood Flow Metab..
    • Mintun, M.A.1    Raichle, M.E.2    Quarles, R.P.3
  • 7
    • 0028847571 scopus 로고    scopus 로고
    • Improved signal-to-noise in PET activation studies using switched paradigms, vol. 36, pp. 307-314, 1995.
    • S. R. Cherry, R. P. Woods, N. K. Doshi, P. K. Banerjee, and J. C. Mazziotta, "Improved signal-to-noise in PET activation studies using switched paradigms," J. Nucl. Med.. vol. 36, pp. 307-314, 1995.
    • J. Nucl. Med..
    • Cherry, S.R.1    Woods, R.P.2    Doshi, N.K.3    Banerjee, P.K.4    Mazziotta, J.C.5
  • 10
    • 33747937674 scopus 로고    scopus 로고
    • PET H2150 activation studies using a short InterScan interval and background-subtraction technique, vol. 3, no. 3, p. S19, 1996.
    • G. F. Eden, K. Keil, J. M. Maisog, R. E. Carson, P. Herscovitch, and J. V. Haxby, "PET H2150 activation studies using a short InterScan interval and background-subtraction technique," Neuroimage, vol. 3, no. 3, p. S19, 1996.
    • Neuroimage
    • Eden, G.F.1    Keil, K.2    Maisog, J.M.3    Carson, R.E.4    Herscovitch, P.5    Haxby, J.V.6
  • 11
    • 0023722018 scopus 로고    scopus 로고
    • Enhanced detection of focal brain responses using intersubject averaging and change-distribution analysis of subtracted PET images, vol. 8, pp. 642-653, 1988.
    • P. T. Fox, M. A. Mintun, E. M. Reiman, and M. E. Raichle, "Enhanced detection of focal brain responses using intersubject averaging and change-distribution analysis of subtracted PET images," J. Cereb. Blood Flow Metab., vol. 8, pp. 642-653, 1988.
    • J. Cereb. Blood Flow Metab.
    • Fox, P.T.1    Mintun, M.A.2    Reiman, E.M.3    Raichle, M.E.4
  • 13
    • 0001171133 scopus 로고    scopus 로고
    • Performance evaluation of the whole-body PET scanner ECAT EXACT HR+ following the IEC standard, vol. 44, pp. 1172-1179, 1997.
    • L.-E. Adam, J. Zaers, H. Ostertag, H. Trojan, M. E. Bellemann, and G. Brix, "Performance evaluation of the whole-body PET scanner ECAT EXACT HR+ following the IEC standard," IEEE Trans. Nucl. Sci., vol. 44, pp. 1172-1179, 1997.
    • IEEE Trans. Nucl. Sci.
    • Adam, L.-E.1    Zaers, J.2    Ostertag, H.3    Trojan, H.4    Bellemann, M.E.5    Brix, G.6
  • 15
    • 0028040173 scopus 로고    scopus 로고
    • Practice-related changes in human brain functional anatomy during nonmotor learning, Cereb. vol. 4, no. 1, pp. 8-26, 1994.
    • M. E. Raichle, V. A. Fiez, and T. O. Videen et al., "Practice-related changes in human brain functional anatomy during nonmotor learning," Cereb. Cortex, vol. 4, no. 1, pp. 8-26, 1994.
    • Cortex
    • Raichle, M.E.1    Fiez, V.A.2    Videen, T.O.3
  • 16
    • 0025891598 scopus 로고    scopus 로고
    • Attention modulates somatosensory cerebral blood flow response to vibrotactile stimulation as measured by positron emission tomography, Ann. Neural., vol. 29, no. 4, pp. 440-443, 1991.
    • E. Meyer, S. S. Ferguson, and R. J. Zatorre etal, "Attention modulates somatosensory cerebral blood flow response to vibrotactile stimulation as measured by positron emission tomography," Ann. Neural., vol. 29, no. 4, pp. 440-443, 1991.
    • Etal
    • Meyer, E.1    Ferguson, S.S.2    Zatorre, R.J.3
  • 18
    • 0026781154 scopus 로고    scopus 로고
    • A threedimensional statistical analysis for CBF activation studies in human brain, vol. 12, pp. 900-918, 1992.
    • K. J. Worsley, A. C. Evans, S. Marrett, and P. Neelin, "A threedimensional statistical analysis for CBF activation studies in human brain," J. Cereb. Blood Flow Metab., vol. 12, pp. 900-918, 1992.
    • J. Cereb. Blood Flow Metab.
    • Worsley, K.J.1    Evans, A.C.2    Marrett, S.3    Neelin, P.4
  • 19
    • 33747924616 scopus 로고    scopus 로고
    • Co-planar stereotaxic atlas of the human brain. New York: Thieme Medical, 1988.
    • J. Talairach and P. Tournoux, "Co-planar stereotaxic atlas of the human brain." New York: Thieme Medical, 1988.
    • Talairach, J.1    Tournoux, P.2
  • 20
    • 0025414253 scopus 로고    scopus 로고
    • Measuring PET scanner sensitivity: Relating count rates to image signal-to-noise ratios using noise equivalent counts, vol. 37, no. 2, pp. 783-788, 1990.
    • S. C. Strother, M. E. Casey, and E. J. Huffman, "Measuring PET scanner sensitivity: Relating count rates to image signal-to-noise ratios using noise equivalent counts," IEEE Trans Nucl. Sci., vol. 37, no. 2, pp. 783-788, 1990.
    • IEEE Trans Nucl. Sci.
    • Strother, S.C.1    Casey, M.E.2    Huffman, E.J.3
  • 21
    • 33748006123 scopus 로고    scopus 로고
    • 3D PET activation studies with an H215O bolus injection: Count rate performance and dose optimization, R. Myers, V. Cunningham, D. Bailey, T. Jones, ed., in 1996, pp. 93-97.
    • S. Holm, I. Law, O. B. Paulson, "3D PET activation studies with an H215O bolus injection: Count rate performance and dose optimization," R. Myers, V. Cunningham, D. Bailey, T. Jones, ed., in Quantification of Brain Function Using PET. San Diego, CA: Academic, 1996, pp. 93-97.
    • Quantification of Brain Function Using PET. San Diego, CA: Academic
    • Holm, S.1    Law, I.2    Paulson, O.B.3
  • 22
    • 0030129292 scopus 로고    scopus 로고
    • Signal-to-noise ratio in neuro activation PET studies, vol. 15, no. 2, pp. 197-205, 1996.
    • J. R. Votaw, "Signal-to-noise ratio in neuro activation PET studies," IEEE Trans Med Imag., vol. 15, no. 2, pp. 197-205, 1996.
    • IEEE Trans Med Imag.
    • Votaw, J.R.1
  • 24
    • 0026508681 scopus 로고    scopus 로고
    • Lateralization of phonetic and pitch discrimination in speech processing, Sci., vol. 256, no. 5058, pp. 846-9, 1992.
    • R. J. Zatorre, A. C. Evans, E. Meyer, and A. Gjedde, "Lateralization of phonetic and pitch discrimination in speech processing," Sci., vol. 256, no. 5058, pp. 846-9, 1992.
    • Zatorre, R.J.1    Evans, A.C.2    Meyer, E.3    Gjedde, A.4
  • 25
    • 0029837375 scopus 로고    scopus 로고
    • Interhemispheric anatomical differences in human primary auditory cortex: Probabilistic mapping and volume measurement from magnetic resonance scans, vol. 6, pp. 661-672, 1996.
    • V. B. Penhune, R. J. Zatorre, J. D. MacDonald, and A. C. Evans, "Interhemispheric anatomical differences in human primary auditory cortex: Probabilistic mapping and volume measurement from magnetic resonance scans," Cereb. Cortex, vol. 6, pp. 661-672, 1996.
    • Cereb. Cortex
    • Penhune, V.B.1    Zatorre, R.J.2    MacDonald, J.D.3    Evans, A.C.4
  • 26
    • 44349129408 scopus 로고    scopus 로고
    • The theory and application of the exchange of inert gas at the lungs and tissues, vol. 3, pp. 1-41, 1951.
    • S. S. Kety, "The theory and application of the exchange of inert gas at the lungs and tissues," Pharmacol. Rev., vol. 3, pp. 1-41, 1951.
    • Pharmacol. Rev.
    • Kety, S.S.1
  • 28
    • 33747988990 scopus 로고    scopus 로고
    • Re-evaluating the precision of localizing activation foci by identifying local maxima in subtracted PET images, Personal Communications.
    • J. J. Moreno-Cantu, Y. Ma, C. J. Thompson, R. J. Zatorre, and M. Petrides, "Re-evaluating the precision of localizing activation foci by identifying local maxima in subtracted PET images," Personal Communications.
    • Moreno-Cantu, J.J.1    Ma, Y.2    Thompson, C.J.3    Zatorre, R.J.4    Petrides, M.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.