메뉴 건너뛰기




Volumn 45, Issue 6, 1998, Pages 1453-1460

Dynamics of an ultrasonic transducer used for wire bonding

Author keywords

[No Author keywords available]

Indexed keywords

BONDING; FINITE ELEMENT METHOD; NATURAL FREQUENCIES; PIEZOELECTRIC TRANSDUCERS; SENSORS; VIBRATION MEASUREMENT;

EID: 0032208347     PISSN: 08853010     EISSN: None     Source Type: Journal    
DOI: 10.1109/58.738285     Document Type: Article
Times cited : (46)

References (15)
  • 2
    • 84948211093 scopus 로고
    • Quality control in ultrasonic wire bonding
    • R. Rodwell and D. A. Worrall, "Quality control in ultrasonic wire bonding," Hybrid Circuits, no. 7, pp. 67-72, 1985.
    • (1985) Hybrid Circuits , Issue.7 , pp. 67-72
    • Rodwell, R.1    Worrall, D.A.2
  • 4
    • 0022808102 scopus 로고
    • Development of non-destructive bond monitoring techniques for ultrasonic bonders
    • Nov.
    • N. M. Bilgutay, X. Li, and M. McBrearty, "Development of non-destructive bond monitoring techniques for ultrasonic bonders," Ultrasonics, vol. 24, pp. 307-317, Nov. 1986.
    • (1986) Ultrasonics , vol.24 , pp. 307-317
    • Bilgutay, N.M.1    Li, X.2    McBrearty, M.3
  • 5
    • 0008757151 scopus 로고
    • Theory and analysis of sectional concentrators
    • L. C. Markulov and A. V. Kharitonov, ''Theory and analysis of sectional concentrators," Sov. Phys. - Acoust., vol. 5, pp. 183-190, 1959.
    • (1959) Sov. Phys. - Acoust. , vol.5 , pp. 183-190
    • Markulov, L.C.1    Kharitonov, A.V.2
  • 6
    • 0015728072 scopus 로고
    • The pre-stressed piezoelectric sandwich transducer
    • E. A. Neppiras, "The pre-stressed piezoelectric sandwich transducer," in Proc. Ultrason. Int. Conf., 1973, pp. 295-302.
    • (1973) Proc. Ultrason. Int. Conf. , pp. 295-302
    • Neppiras, E.A.1
  • 7
    • 0029173053 scopus 로고
    • Optimum design for sandwich transducer - By analyzing effects of structure and material parameters of transducer on its performance, Acta Acust
    • Jan.
    • Z. Yan and Z. Lin, "Optimum design for sandwich transducer - by analyzing effects of structure and material parameters of transducer on its performance," Acta Acust., vol. 20, no. 1, pp. 18-25, Jan. 1995.
    • (1995) Z. Lin , vol.20 , Issue.1 , pp. 18-25
    • Yan, Z.1
  • 10
    • 0000183043 scopus 로고
    • Optical probing of the mechanical impulse response of a transducer
    • D. Royer and E. Dieulesaint, "Optical probing of the mechanical impulse response of a transducer," Appl. Phys. Lett., no. 49, pp. 1056-1058, 1986.
    • (1986) Appl. Phys. Lett., No. , vol.49 , pp. 1056-1058
    • Royer, D.1    Dieulesaint, E.2
  • 12
    • 0026926287 scopus 로고
    • Measurement of piezoelectric constants using an optical heterodyne interferometer
    • D. Royer and V. Kmetik, "Measurement of piezoelectric constants using an optical heterodyne interferometer," Electron. Lett., vol. 28, pp. 1828-1830, 1992.
    • (1992) Electron. Lett. , vol.28 , pp. 1828-1830
    • Royer, D.1    Kmetik, V.2
  • 14
    • 0026344980 scopus 로고
    • Dynamics of an ultrasonic bonding tool: A case study in P-version finite-element analysis
    • R. B. Morris, P. Carnevali, and W. T. Randy, "Dynamics of an ultrasonic bonding tool: A case study in P-version finite-element analysis," J. Acoust. Soc. Amer., vol. 90, no. 6, pp. 2919-2923, 1991.
    • (1991) J. Acoust. Soc. Amer. , vol.90 , Issue.6 , pp. 2919-2923
    • Morris, R.B.1    Carnevali, P.2    Randy, W.T.3
  • 15
    • 0032002326 scopus 로고    scopus 로고
    • Ultrasonic wire bond quality monitoring using piezoelectric sensor
    • S. W. Or, H. L. W. Chan, V. C. Lo, and C. W. Yuen, "Ultrasonic wire bond quality monitoring using piezoelectric sensor," Sens. Actuators A: Physical, vol. 65, pp. 69-75, 1998.
    • (1998) Sens. Actuators A: Physical , vol.65 , pp. 69-75
    • Or, S.W.1    Chan, H.L.W.2    Lo, V.C.3    Yuen, C.W.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.