메뉴 건너뛰기




Volumn 28, Issue 3, 1998, Pages 270-275

Reproducibility of phalanx osteosonography and relation with forearm peripheral quantitative computed tomography: Single finger versus average measurement on the last four fingers

Author keywords

Bone mineral density; Peripheral quantitative computed tomography; Phalanx; Speed of sound

Indexed keywords

BONE; COMPUTERIZED TOMOGRAPHY; DISEASES; ULTRASONIC APPLICATIONS;

EID: 0032191994     PISSN: 0720048X     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0720-048X(97)00180-0     Document Type: Article
Times cited : (3)

References (17)
  • 1
    • 0031040692 scopus 로고    scopus 로고
    • The role of ultrasound in the assessment of osteoporosis: A review
    • [1] Njeh CF, Boivin CM, Langton CM. The role of ultrasound in the assessment of osteoporosis: a review. Osteoporosis Int 1997;7:7-22.
    • (1997) Osteoporosis Int , vol.7 , pp. 7-22
    • Njeh, C.F.1    Boivin, C.M.2    Langton, C.M.3
  • 2
    • 0028472419 scopus 로고
    • Valutazione del tessuto osseo con ultrasuoni (us) sulla falange prostimale delle mani nelle pazienti con sospetta osteoporosi di tipo i
    • [2] Lusenti T, Cadossi R, Franco V, Soliani F, Rustichelli R, Borgatti PP. Valutazione del tessuto osseo con ultrasuoni (US) sulla falange prostimale delle mani nelle pazienti con sospetta osteoporosi di tipo I. Minerva Ginecol 1994;46:423-8.
    • (1994) Minerva Ginecol , vol.46 , pp. 423-428
    • Lusenti, T.1    Cadossi, R.2    Franco, V.3    Soliani, F.4    Rustichelli, R.5    Borgatti, P.P.6
  • 3
    • 0029980204 scopus 로고    scopus 로고
    • Ultrasound velocity measured at the proximal phalanges: Precision and age-related changes in normal females
    • [3] Duboeuf F, Hans D, Schott AM, Giraud S, Delmas PD, Meunier PY. Ultrasound velocity measured at the proximal phalanges: precision and age-related changes in normal females. Rev Rhum 1996;63:427-34.
    • (1996) Rev Rhum , vol.63 , pp. 427-434
    • Duboeuf, F.1    Hans, D.2    Schott, A.M.3    Giraud, S.4    Delmas, P.D.5    Meunier, P.Y.6
  • 4
    • 0029955929 scopus 로고    scopus 로고
    • Ultrasound velocity changes at the proximal phalanxes of the hand in pre, peri and postmenopausal women
    • [4] Ventura V, Mauloni M, Mura M, Paltrinieri F, de Aloysio D. Ultrasound velocity changes at the proximal phalanxes of the hand in pre, peri and postmenopausal women. Osteoporosis Int 1996;6:368-75.
    • (1996) Osteoporosis Int , vol.6 , pp. 368-375
    • Ventura, V.1    Mauloni, M.2    Mura, M.3    Paltrinieri, F.4    De Aloysio, D.5
  • 5
    • 0031031141 scopus 로고    scopus 로고
    • Ultrasound bone velocity on proximal phalanges in premenopausal, perimenopausal and postmenopausal healthy women
    • [5] Aguado F, Revilla M, Hernandez ER, Villa LF, Rico H. Ultrasound bone velocity on proximal phalanges in premenopausal, perimenopausal and postmenopausal healthy women. Invest Radiol 1997;32:66-70.
    • (1997) Invest Radiol , vol.32 , pp. 66-70
    • Aguado, F.1    Revilla, M.2    Hernandez, E.R.3    Villa, L.F.4    Rico, H.5
  • 6
    • 0029941310 scopus 로고    scopus 로고
    • Pathways of transmission of ultrasound energy through the distal metaphysis of the second phalanx of pigs: An in vitro study
    • [6] Cadossi R, Cane V. Pathways of transmission of ultrasound energy through the distal metaphysis of the second phalanx of pigs: an in vitro study. Osteoporosis Int 1996;6:196-206.
    • (1996) Osteoporosis Int , vol.6 , pp. 196-206
    • Cadossi, R.1    Cane, V.2
  • 7
    • 0029018518 scopus 로고
    • Quantitative ultrasound bone measurements: Normal values and comparison with bone mineral density by dual X-ray absorptiometry
    • [7] Moris M, Peretz A, Tjeka R, Negaban N, Wouters M, Bergmann P. Quantitative ultrasound bone measurements: normal values and comparison with bone mineral density by dual X-ray absorptiometry. Calcif Tissue Int 1995;57:6-10.
    • (1995) Calcif Tissue Int , vol.57 , pp. 6-10
    • Moris, M.1    Peretz, A.2    Tjeka, R.3    Negaban, N.4    Wouters, M.5    Bergmann, P.6
  • 8
    • 0027234809 scopus 로고
    • Ultrasound measurements on os calcis: Precision and age related changes in normal female population
    • [8] Schott AM, Hans D, Sornay-Rendu E, Delmas PD, Meunier PJ. Ultrasound measurements on os calcis: precision and age related changes in normal female population. Osteoporosis Int 1993;3:249-54.
    • (1993) Osteoporosis Int , vol.3 , pp. 249-254
    • Schott, A.M.1    Hans, D.2    Sornay-Rendu, E.3    Delmas, P.D.4    Meunier, P.J.5
  • 9
    • 0027771324 scopus 로고
    • Apparent velocity of ultrasound (AVU) at the patella in comparison to bone mineral density at the lumbar spine in normal males and females
    • [9] Wapniarz M, Lehmann R, Banik N, Radwan R, Klein K, Allolio B. Apparent velocity of ultrasound (AVU) at the patella in comparison to bone mineral density at the lumbar spine in normal males and females. Bone Miner 1993;23:243-52.
    • (1993) Bone Miner , vol.23 , pp. 243-252
    • Wapniarz, M.1    Lehmann, R.2    Banik, N.3    Radwan, R.4    Klein, K.5    Allolio, B.6
  • 10
    • 0029046429 scopus 로고
    • Ultrasound in the evaluation of Osteoporosis: A comparison with bone mineral density at distal radius
    • [10] Gnudi S, Malavolta N, Ripamonti C, Caudarella R. Ultrasound in the evaluation of Osteoporosis: a comparison with bone mineral density at distal radius. Br J Radiol 1995;68:476-80.
    • (1995) Br J Radiol , vol.68 , pp. 476-480
    • Gnudi, S.1    Malavolta, N.2    Ripamonti, C.3    Caudarella, R.4
  • 11
    • 0027096823 scopus 로고
    • The relationship between ultrasound and densitometric measurements of bone mass at the calcaneus in women
    • [11] Waud CE, Lew R, Baran DT. The relationship between ultrasound and densitometric measurements of bone mass at the calcaneus in women. Calcif Tissue Int 1992;51:415-8.
    • (1992) Calcif Tissue Int , vol.51 , pp. 415-418
    • Waud, C.E.1    Lew, R.2    Baran, D.T.3
  • 13
    • 0000227577 scopus 로고    scopus 로고
    • Comparison between a new ultrasound densitometer and single-photon absorptiometry
    • [13] Murgia C, Cagnacci A, Paoletti AM, Pilia I, Meloni A, Melis GB. Comparison between a new ultrasound densitometer and single-photon absorptiometry. Menopause 1996;3:149-53.
    • (1996) Menopause , vol.3 , pp. 149-153
    • Murgia, C.1    Cagnacci, A.2    Paoletti, A.M.3    Pilia, I.4    Meloni, A.5    Melis, G.B.6
  • 14
    • 0027204802 scopus 로고
    • Broadband ultrasound signals depend on trabecular orientation: An in vitro study
    • [14] Gluër CC, Wu CY, Genant HK. Broadband ultrasound signals depend on trabecular orientation: an in vitro study. Osteoporosis Int 1993;3:185-91.
    • (1993) Osteoporosis Int , vol.3 , pp. 185-191
    • Gluër, C.C.1    Wu, C.Y.2    Genant, H.K.3
  • 15
    • 0031081116 scopus 로고    scopus 로고
    • In vitro assessment of the relationship between acoustic properties and bone mass density of the calcaneus by comparison of ultrasound parametric imaging and quantitative computed tomography
    • [15] Laugier P, Droin P, Lavai-Jeantet AM, Berger G. In vitro assessment of the relationship between acoustic properties and bone mass density of the calcaneus by comparison of ultrasound parametric imaging and quantitative computed tomography. Bone 1997;20:157-65.
    • (1997) Bone , vol.20 , pp. 157-165
    • Laugier, P.1    Droin, P.2    Lavai-Jeantet, A.M.3    Berger, G.4
  • 16
    • 0029940024 scopus 로고    scopus 로고
    • Cortical and total bone mineral content of the radius: Accuracy of peripheral computed tomography
    • [16] Louis O, Soykens S, Willnecker J, Van Den Winkel P, Osteaux M. Cortical and total bone mineral content of the radius: accuracy of peripheral computed tomography. Bone 1996;18:467-72.
    • (1996) Bone , vol.18 , pp. 467-472
    • Louis, O.1    Soykens, S.2    Willnecker, J.3    Van Den Winkel, P.4    Osteaux, M.5
  • 17
    • 0030004410 scopus 로고    scopus 로고
    • Quantitative CT assessment of the lumbar spine and radius in patients with osteoporosis
    • [17] Grampp S, Yergas M, Lang P, et al. Quantitative CT assessment of the lumbar spine and radius in patients with osteoporosis. Am J Roentgenol 1996;167:133-40.
    • (1996) Am J Roentgenol , vol.167 , pp. 133-140
    • Grampp, S.1    Yergas, M.2    Lang, P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.