메뉴 건너뛰기




Volumn 13, Issue 7-8, 1998, Pages 839-845

Development of a biosensor for E. coli based on a flexural plate wave (FPW) transducer

Author keywords

E. coli; EDC; Escherichia coli; FPW, flexural plate wave; L ethyl 3 (3 dimethylaminopropyl) carbodiimide; NHS, N hydroxysuccinimide

Indexed keywords

ACOUSTO-GRAVIMETRIC FLEXURAL PLATE WAVE TRANSDUCERS; ETHYLDIMETHYLAMINOPROPYL CARBODIIMIDE; HYDROXYSUCCINIMIDE; MOLECULAR RECOGNITION; POLYACRYLIC ACID;

EID: 0032190779     PISSN: 09565663     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0956-5663(98)00050-5     Document Type: Article
Times cited : (79)

References (13)
  • 1
    • 0027579004 scopus 로고
    • Electrostatic excitation and capacitive detection of flexural plate-waves
    • Giesler T., Meyer J.-U. Electrostatic excitation and capacitive detection of flexural plate-waves. Sens. & Act. A. 36:1993;113-119.
    • (1993) Sens. & Act. a , vol.36 , pp. 113-119
    • Giesler, T.1    Meyer, J.-U.2
  • 2
    • 0028386999 scopus 로고
    • Electrostatically excited and capacitively detected flexural plate waves on thin silicon nitride membranes with chemical sensor application
    • Giesler T., Meyer J.-U. Electrostatically excited and capacitively detected flexural plate waves on thin silicon nitride membranes with chemical sensor application. Sens. & Act. B. 18 19:1994;103-106.
    • (1994) Sens. & Act. B , vol.18-19 , pp. 103-106
    • Giesler, T.1    Meyer, J.-U.2
  • 3
    • 0026726023 scopus 로고
    • Detection of antithyroglobulin autoantibodies with defined epitopic specificity by a microparticle-enhanced nephelometric immunoassay
    • Harchali A.A., Montagne P., Cuilliere M.L., Bouanani M., Pau B., Duheille J. Detection of antithyroglobulin autoantibodies with defined epitopic specificity by a microparticle-enhanced nephelometric immunoassay. Clin. Chem. 38:1992;1859-1864.
    • (1992) Clin. Chem. , vol.38 , pp. 1859-1864
    • Harchali, A.A.1    Montagne, P.2    Cuilliere, M.L.3    Bouanani, M.4    Pau, B.5    Duheille, J.6
  • 5
    • 37049079283 scopus 로고
    • A novel hydrogel matrix on gold surfaces in surface plasmon resonance sensors for fast and efficient covalent immobilization
    • Löfas, S., Johnsson, B., 1990. A novel hydrogel matrix on gold surfaces in surface plasmon resonance sensors for fast and efficient covalent immobilization. J. Chem. Soc. Chem. Commun. 1526-1528.
    • (1990) J. Chem. Soc. Chem. Commun. , pp. 1526-1528
    • Löfas, S.1    Johnsson, B.2
  • 7
    • 0025256793 scopus 로고
    • New microminiaturized glucose sensors using covalent immobilization techniques
    • Mann-Buxbaum E., Pittner F., Schalkhammer T. New microminiaturized glucose sensors using covalent immobilization techniques. Sens. & Act. B. 1:1990;518-522.
    • (1990) Sens. & Act. B , vol.1 , pp. 518-522
    • Mann-Buxbaum, E.1    Pittner, F.2    Schalkhammer, T.3
  • 8
  • 10
    • 0002272647 scopus 로고
    • Chemical composition of E. coli
    • In: Neidhardt, F.C. (ed.), American Society for Microbiology, Washington
    • Neidhardt, F.C., 1987. Chemical composition of E. coli. In: Neidhardt, F.C. (ed.), Escherichia coli and Salmonella. American Society for Microbiology, Washington, pp. 3-6.
    • (1987) Escherichia Coli and Salmonella , pp. 3-6
    • Neidhardt, F.C.1
  • 11
    • 0001916466 scopus 로고    scopus 로고
    • Direct immunosensors
    • In: Price, C.P., Newman, D.J. (Eds.), Macmillan Reference Ltd., New York
    • Purvis, D.R., Knight, D.P., Lowe, C.R., 1997. Direct immunosensors. In: Price, C.P., Newman, D.J. (Eds.), Principles and Practice of Immunoassays. Macmillan Reference Ltd., New York, pp. 513-538.
    • (1997) Principles and Practice of Immunoassays , pp. 513-538
    • Purvis, D.R.1    Knight, D.P.2    Lowe, C.R.3
  • 12
    • 0017312637 scopus 로고
    • Isoelectric points and molecular weight of proteins
    • Righetti P.G., Caravaggio T. Isoelectric points and molecular weight of proteins. J. Chromatogr. 127:1976;1-28.
    • (1976) J. Chromatogr. , vol.127 , pp. 1-28
    • Righetti, P.G.1    Caravaggio, T.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.