메뉴 건너뛰기




Volumn 17, Issue 5, 1998, Pages 853-856

An iterative algorithm for X-ray CT fluoroscopy

Author keywords

Filtered backprojection (fb); Image noise; Low contrast resolution; Metal artifacts; Motion artifacts; Row action expectation maximization (em); X ray computed tomography fluoroscopy (ctf)

Indexed keywords

ALGORITHM; ARTICLE; COMPUTER ASSISTED TOMOGRAPHY; FLUOROSCOPY; HUMAN; IMAGE PROCESSING; IMAGE QUALITY; INTERVENTIONAL RADIOLOGY;

EID: 0032173375     PISSN: 02780062     EISSN: None     Source Type: Journal    
DOI: 10.1109/42.736058     Document Type: Article
Times cited : (34)

References (22)
  • 1
    • 0029131694 scopus 로고    scopus 로고
    • CT-guided pericardial drainage catheter placement with subsequent pericardial sclerosis, vol. 19, pp. 672-673, 1995.
    • R. J. Bellon, W. H. Wright, and E. C. Unger, "CT-guided pericardial drainage catheter placement with subsequent pericardial sclerosis," J. Comput. Assist. Tomogr., vol. 19, pp. 672-673, 1995.
    • J. Comput. Assist. Tomogr.
    • Bellon, R.J.1    Wright, W.H.2    Unger, E.C.3
  • 2
    • 0029004275 scopus 로고    scopus 로고
    • N. Ozdemir, S. Isiksoy, T. Kaya, M. Ekici, S. Erginel, E. Harmanci, P. Erdinc, N. Ulgey, and F. Alatas CT-guided pleural needle biopsy in the diagnosis of malignant mesothelioma, vol. 19, pp. 370-374, 1995.
    • M. Metintas, N. Ozdemir, S. Isiksoy, T. Kaya, M. Ekici, S. Erginel, E. Harmanci, P. Erdinc, N. Ulgey, and F. Alatas "CT-guided pleural needle biopsy in the diagnosis of malignant mesothelioma," J. Comput. Assist. Tomogr., vol. 19, pp. 370-374, 1995.
    • J. Comput. Assist. Tomogr.
    • Metintas, M.1
  • 3
    • 0029007985 scopus 로고    scopus 로고
    • Percutaneous CT-guided biopsy of adrenal masses: Immediate and delayed complications, vol. 19, pp. 434-439, 1995.
    • M. K. Mody, E. A. Kazerooni, and M. Korobkin, "Percutaneous CT-guided biopsy of adrenal masses: Immediate and delayed complications," J. Comput. Assist. Tomogr., vol. 19, pp. 434-439, 1995.
    • J. Comput. Assist. Tomogr.
    • Mody, M.K.1    Kazerooni, E.A.2    Korobkin, M.3
  • 4
    • 0029907832 scopus 로고    scopus 로고
    • Radiation dosimetry at CT fluoroscopy: Physician's hand dose and development of needle holders, vol. 201, pp. 576-578, 1996.
    • R. Kato, K. Katada, H. Anno, S. Suzuki, Y. Ida, and S. Koga, "Radiation dosimetry at CT fluoroscopy: Physician's hand dose and development of needle holders," Radial., vol. 201, pp. 576-578, 1996.
    • Radial.
    • Kato, R.1    Katada, K.2    Anno, H.3    Suzuki, S.4    Ida, Y.5    Koga, S.6
  • 6
    • 0030666579 scopus 로고    scopus 로고
    • Use of CT-guided marking of the portal vein in creation of 150 transjugular intrahepatic portosystemic shunts, vol. 8, pp. 1073-1077, 1997.
    • A. B. Fontaine, A. Verschyl, E. Hoffer, J. Borsa, and M. Dowd, "Use of CT-guided marking of the portal vein in creation of 150 transjugular intrahepatic portosystemic shunts," J. Vase. Interv. Radial., vol. 8, pp. 1073-1077, 1997.
    • J. Vase. Interv. Radial.
    • Fontaine, A.B.1    Verschyl, A.2    Hoffer, E.3    Borsa, J.4    Dowd, M.5
  • 7
    • 0030833584 scopus 로고    scopus 로고
    • CT-assisted transbronchial needle aspiration: Usefulness of CT fluoroscopy, vol. 169, pp. 393-394, 1997.
    • C. S. White, P. A. Templeton, and J. D. Hasday, "CT-assisted transbronchial needle aspiration: Usefulness of CT fluoroscopy," Amer. J. Roentgenoi, vol. 169, pp. 393-394, 1997.
    • Amer. J. Roentgenoi
    • White, C.S.1    Templeton, P.A.2    Hasday, J.D.3
  • 8
    • 0030912596 scopus 로고    scopus 로고
    • Analysis of the temporal response of computed tomography fluoroscopy, vol. 24, pp. 665-675, 1997.
    • J. Hsieh, "Analysis of the temporal response of computed tomography fluoroscopy," Med. Phys., vol. 24, pp. 665-675, 1997.
    • Med. Phys.
    • Hsieh, J.1
  • 9
    • 0020194763 scopus 로고    scopus 로고
    • Maximum likelihood reconstruction for emission tomography, 1, pp. 113-122, 1982.
    • L. A. Shepp and Y. Vardi, "Maximum likelihood reconstruction for emission tomography," IEEE Trans. Med. Imag., vol. MI-1, pp. 113-122, 1982.
    • IEEE Trans. Med. Imag., Vol. MI
    • Shepp, L.A.1    Vardi, Y.2
  • 11
    • 33748008155 scopus 로고    scopus 로고
    • Why least squares and maximum entropy? An axiomatic approach to inference for linear inverse problems, vol. 19, pp. 2032-2066, 1991.
    • I. Csiszar, "Why least squares and maximum entropy? An axiomatic approach to inference for linear inverse problems, Ann. Statistics, vol. 19, pp. 2032-2066, 1991.
    • Ann. Statistics
    • Csiszar, I.1
  • 13
    • 0030270511 scopus 로고    scopus 로고
    • A row-action alternative to the EM algorithm for maximizing likelihoods in emission tomography, vol. 15, pp. 687-699, 1996.
    • J. Browne and A. R. De Pierro, "A row-action alternative to the EM algorithm for maximizing likelihoods in emission tomography," IEEE Trans. Med. Imag., vol. 15, pp. 687-699, 1996.
    • IEEE Trans. Med. Imag.
    • Browne, J.1    De Pierro, A.R.2
  • 14
    • 0028700063 scopus 로고    scopus 로고
    • Accelerated image reconstruction using ordered subsets of projection data, vol. 13, pp. 601-609, 1994.
    • H. M. Hudson and R. S. Larkin, "Accelerated image reconstruction using ordered subsets of projection data," IEEE Trans. Med. Imag., vol. 13, pp. 601-609, 1994.
    • IEEE Trans. Med. Imag.
    • Hudson, H.M.1    Larkin, R.S.2
  • 15
    • 0027659444 scopus 로고    scopus 로고
    • Algebraic reconstruction techniques can be made computationally efficient, vol. 12, pp. 600-609, 1993.
    • G. T. Herman and L. B. Meyer, "Algebraic reconstruction techniques can be made computationally efficient," IEEE Trans. Med. Imag., vol. 12, pp. 600-609, 1993.
    • IEEE Trans. Med. Imag.
    • Herman, G.T.1    Meyer, L.B.2
  • 16
    • 0030165465 scopus 로고    scopus 로고
    • Evaluation of OSEM versus ML-EM for ID, 2-D and fully 3-D SPECT reconstruction, vol. 43, pp. 2018-2024, 1996.
    • C. Kamphuis, F. J. Beekman, and M. A. Viergever, "Evaluation of OSEM versus ML-EM for ID, 2-D and fully 3-D SPECT reconstruction," IEEE Trans. Nucl. Sci., vol. 43, pp. 2018-2024, 1996.
    • IEEE Trans. Nucl. Sci.
    • Kamphuis, C.1    Beekman, F.J.2    Viergever, M.A.3
  • 17
    • 0031951077 scopus 로고    scopus 로고
    • Dual matrix ordered subsets reconstruction for accelerated 3-D scatter compensation in single-photon emission tomography, vol. 25, pp. 8-18, 1998.
    • C. Kamphuis, F. J. Beekman, P. P. van Rijk, and M. A. Viergever, "Dual matrix ordered subsets reconstruction for accelerated 3-D scatter compensation in single-photon emission tomography," Eur. J. Nucl. Med., vol. 25, pp. 8-18, 1998.
    • Eur. J. Nucl. Med.
    • Kamphuis, C.1    Beekman, F.J.2    Van Rijk, P.P.3    Viergever, M.A.4
  • 18
    • 0021327145 scopus 로고    scopus 로고
    • EM reconstruction algorithms for emission and transmission tomography, vol. 8, pp. 306-316, 1984.
    • K. Lange and R. Carson, "EM reconstruction algorithms for emission and transmission tomography," J. Comput. Assist. Tomogr., vol. 8, pp. 306-316, 1984.
    • J. Comput. Assist. Tomogr.
    • Lange, K.1    Carson, R.2
  • 19
    • 0029392038 scopus 로고    scopus 로고
    • Penalized maximum-likelihood image reconstruction using space-alternating generalized EM algorithms, vol. 4, pp. 1417-1429, 1995.
    • J. A. Fessier and A. O. Hero, III, "Penalized maximum-likelihood image reconstruction using space-alternating generalized EM algorithms," IEEE Trans. Image Processing, vol. 4, pp. 1417-1429, 1995.
    • IEEE Trans. Image Processing
    • Fessier, J.A.1    Hero III, A.O.2
  • 20
    • 0029394375 scopus 로고    scopus 로고
    • Globally convergent algorithms for maximum a posteriori transmission tomography, vol. 4, pp. 1430-1438, 1995.
    • K. Lange and J. A. Fessier, "Globally convergent algorithms for maximum a posteriori transmission tomography," IEEE Trans. Image Processing, vol. 4, pp. 1430-1438, 1995.
    • IEEE Trans. Image Processing
    • Lange, K.1    Fessier, J.A.2
  • 21
    • 0029394437 scopus 로고    scopus 로고
    • Hybrid Poisson/Polynomial objective functions for tomographic image reconstruction from transmission scans, vol. 4, pp. 1439-1450, 1995.
    • J. A. Fessier, "Hybrid Poisson/Polynomial objective functions for tomographic image reconstruction from transmission scans," IEEE Trans. Image Processing, vol. 4, pp. 1439-1450, 1995.
    • IEEE Trans. Image Processing
    • Fessier, J.A.1
  • 22
    • 0031106957 scopus 로고    scopus 로고
    • Groupedcoordinate ascent algorithms for penalized-likelihood transmission image reconstruction, vol. 16, pp. 166-175, 1997.
    • J. A. Fessier, E. P. Ficaro, N. H. Clinthorne, and K. Lange, "Groupedcoordinate ascent algorithms for penalized-likelihood transmission image reconstruction," IEEE Trans. Med. Imag., vol. 16, pp. 166-175, 1997.
    • IEEE Trans. Med. Imag.
    • Fessier, J.A.1    Ficaro, E.P.2    Clinthorne, N.H.3    Lange, K.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.