메뉴 건너뛰기




Volumn 45, Issue 7, 1998, Pages 921-927

Measuring the progression of foreign-body reaction to silicone implants using in vivo MR microscopy

Author keywords

Foreign body reaction; Implanted RF coils; Magnetic resonance microscopy

Indexed keywords

IMPLANTS (SURGICAL); LIVING SYSTEMS STUDIES; MAGNETIC RESONANCE IMAGING; MICROSCOPIC EXAMINATION; MUSCLE; SILICONES;

EID: 0032125704     PISSN: 00189294     EISSN: None     Source Type: Journal    
DOI: 10.1109/10.686800     Document Type: Article
Times cited : (5)

References (22)
  • 1
    • 0029311037 scopus 로고    scopus 로고
    • Biological performance of a degradable poly (lactic acid-epsilon-caprolactone) nerve guide: Influence of tube dimensions, / vol. 29, pp. 757-766, 1995.
    • W. F. den Dünnen, B. van der Lei, P. H. Robinson, A. Holwerda, A. J. Pennings, and J. M. Schakenraad, "Biological performance of a degradable poly (lactic acid-epsilon-caprolactone) nerve guide: Influence of tube dimensions, "/ Biomed. Mater. Res., vol. 29, pp. 757-766, 1995.
    • Biomed. Mater. Res.
    • Den Dünnen, W.F.1    Van Der Lei, B.2    Robinson, P.H.3    Holwerda, A.4    Pennings, A.J.5    Schakenraad, J.M.6
  • 2
    • 0024955698 scopus 로고    scopus 로고
    • Microtopography and soft tissue response, vol. 2, pp. 51-74, 1989.
    • C. E. Campbell and A. F. von Recum, "Microtopography and soft tissue response, "J. Invest. Surg., vol. 2, pp. 51-74, 1989.
    • J. Invest. Surg.
    • Campbell, C.E.1    Von Recum, A.F.2
  • 3
    • 0027359610 scopus 로고    scopus 로고
    • Development of an animal model for testing human breast implantation materials, vol. 21, pp. 261-273, 1993.
    • D. E. Devor, M. P. Waalkes, P. Goering, and S. Rehm, "Development of an animal model for testing human breast implantation materials, "Toxicol. Pathol, vol. 21, pp. 261-273, 1993.
    • Toxicol. Pathol
    • Devor, D.E.1    Waalkes, M.P.2    Goering, P.3    Rehm, S.4
  • 4
    • 0028339870 scopus 로고    scopus 로고
    • The capsular overgrowth on microencapsulated pancreatic islet grafts in streptozotocin and autoimmune diabetic rats, vol. 7, pp. 264-271, 1994.
    • W. M. Fritschy, P. de Vos, H. Groen, F. A. Klatter, A. Pasma, G. H. Wolters, and R. van Schilfgaarde, "The capsular overgrowth on microencapsulated pancreatic islet grafts in streptozotocin and autoimmune diabetic rats, "Transpl. Int., vol. 7, pp. 264-271, 1994.
    • Transpl. Int.
    • Fritschy, W.M.1    De Vos, P.2    Groen, H.3    Klatter, F.A.4    Pasma, A.5    Wolters, G.H.6    Van Schilfgaarde, R.7
  • 5
    • 0026495645 scopus 로고    scopus 로고
    • Histological and biochemical analysis of the fibrous tissue induced by implantation of synthetic ligament (Dacron): An experimental study in a rat model, vol. 10, pp. 886-894, 1992.
    • K. Irie, H. Kurosawa, and H. Oda, "Histological and biochemical analysis of the fibrous tissue induced by implantation of synthetic ligament (Dacron): An experimental study in a rat model, "J. Orthop. Res., vol. 10, pp. 886-894, 1992.
    • J. Orthop. Res.
    • Irie, K.1    Kurosawa, H.2    Oda, H.3
  • 6
    • 0018183589 scopus 로고    scopus 로고
    • Study of encapsulation of silicone rubber implants in animals. A foreign-body reaction, vol. 62, pp. 580-588, 1978.
    • L. M. Vistnes, G. A. Ksander, and J. Kosek, "Study of encapsulation of silicone rubber implants in animals. A foreign-body reaction, "Plast. Reconstr. Surg.. vol. 62, pp. 580-588, 1978.
    • Plast. Reconstr. Surg..
    • Vistnes, L.M.1    Ksander, G.A.2    Kosek, J.3
  • 7
    • 0028201717 scopus 로고    scopus 로고
    • Soft-tissue response to synthetic biomaterials. [Review], vol. 27, pp. 195-201, 1994.
    • J. M. Morehead and G. R. Holt, "Soft-tissue response to synthetic biomaterials. [Review], "Otolaryngol. Clin. North Amer., vol. 27, pp. 195-201, 1994.
    • Otolaryngol. Clin. North Amer.
    • Morehead, J.M.1    Holt, G.R.2
  • 8
    • 0028122846 scopus 로고    scopus 로고
    • Silicone breast prostheses implantation and explantation, vol. 24, pp. 8-10, 1994.
    • R. J. Friedman, "Silicone breast prostheses implantation and explantation, "Seminars in Arthritis, Rheumatiosm, vol. 24, pp. 8-10, 1994.
    • Seminars in Arthritis, Rheumatiosm
    • Friedman, R.J.1
  • 10
    • 0027193084 scopus 로고    scopus 로고
    • Peptide growth factors and myofibroblasts in capsules around human breast implants, vol. 91, pp. 1277-1286, 1993.
    • C. Lossing and H. A. Hansson, "Peptide growth factors and myofibroblasts in capsules around human breast implants, "Plast. Reconstr. Surg., vol. 91, pp. 1277-1286, 1993.
    • Plast. Reconstr. Surg.
    • Lossing, C.1    Hansson, H.A.2
  • 12
    • 0028868716 scopus 로고    scopus 로고
    • Noninvasive follow-up of tissue encapsulation of foreign materials. Are magnetic resonance imaging and spectroscopy breakthroughs?, vol. 41, pp. M617-M624, 1995.
    • N. Alikacem, P. W. Stroman, Y. Marois, B. Jakubiec, R. Roy, and R. Guidoin, "Noninvasive follow-up of tissue encapsulation of foreign materials. Are magnetic resonance imaging and spectroscopy breakthroughs?, "Asaio. J., vol. 41, pp. M617-M624, 1995.
    • Asaio. J.
    • Alikacem, N.1    Stroman, P.W.2    Marois, Y.3    Jakubiec, B.4    Roy, R.5    Guidoin, R.6
  • 13
    • 0028885027 scopus 로고    scopus 로고
    • Evaluation of the augmented breast. [Review], vol. 33, pp. 1131-1145, 1995.
    • H. E. Reynolds, "Evaluation of the augmented breast. [Review], "Radial. Clin. North Amer., vol. 33, pp. 1131-1145, 1995.
    • Radial. Clin. North Amer.
    • Reynolds, H.E.1
  • 14
    • 0025340863 scopus 로고    scopus 로고
    • Maximizing contrast to noise with indictively coupled implanted coils, vol. 25, pp. 552-558, 1990.
    • T. H. R. Farmer, G. P. Cofer, and G. A. Johnson, "Maximizing contrast to noise with indictively coupled implanted coils, "Invest. Radial., vol. 25, pp. 552-558, 1990.
    • Invest. Radial.
    • Farmer, T.H.R.1    Cofer, G.P.2    Johnson, G.A.3
  • 15
    • 0028072726 scopus 로고    scopus 로고
    • Magnetic resonance microscopy of the rat carotid artery at 300 MHz, vol. 29, pp. 822-826, 1994.
    • L. Arnder, X. Zhou, G. Cofer, G. Mills, L. Hedlund, and G. Johnson, "Magnetic resonance microscopy of the rat carotid artery at 300 MHz, "Invest. Radial., vol. 29, pp. 822-826, 1994.
    • Invest. Radial.
    • Arnder, L.1    Zhou, X.2    Cofer, G.3    Mills, G.4    Hedlund, L.5    Johnson, G.6
  • 16
    • 0026584196 scopus 로고    scopus 로고
    • A probe for specimen magnetic resonance microscopy, vol. 27, pp. 157-164, 1992.
    • M. B. Banson, G. P. Cofer, R. D. Black, and G. A. Johnson, "A probe for specimen magnetic resonance microscopy, "Invest. Radial., vol. 27, pp. 157-164, 1992.
    • Invest. Radial.
    • Banson, M.B.1    Cofer, G.P.2    Black, R.D.3    Johnson, G.A.4
  • 17
    • 0029030687 scopus 로고    scopus 로고
    • MR microscopy of the rat carotid artery after balloon injury by using an implanted imaging coil, vol. 33, pp. 785-789, 1995.
    • R. M. Summers, L. W. Hedlund, G. P. Cofer, M. B. Gottsman, J. F. Manibo, and G. A. Johnson, "MR microscopy of the rat carotid artery after balloon injury by using an implanted imaging coil, "Magn. Reson. Med., vol. 33, pp. 785-789, 1995.
    • Magn. Reson. Med.
    • Summers, R.M.1    Hedlund, L.W.2    Cofer, G.P.3    Gottsman, M.B.4    Manibo, J.F.5    Johnson, G.A.6
  • 18
    • 0029915548 scopus 로고    scopus 로고
    • SNR comparison between surface coils and implanted coils, vol. 35, pp. 727-733, 1996.
    • L. Arnder, M. Shattuck, and R. Black, "SNR comparison between surface coils and implanted coils, "Magn. Reson. Med., vol. 35, pp. 727-733, 1996.
    • Magn. Reson. Med.
    • Arnder, L.1    Shattuck, M.2    Black, R.3
  • 20
    • 0026742382 scopus 로고    scopus 로고
    • Mechanism of detection of acute cerebral ischemia in rats by diffusion-weighted magnetic resonance microscopy, vol. 23, pp. 746-754, 1992.
    • H. Benveniste, L. W. Hedlund, and G. A. Johnson, "Mechanism of detection of acute cerebral ischemia in rats by diffusion-weighted magnetic resonance microscopy, "Stroke, vol. 23, pp. 746-754, 1992.
    • Stroke
    • Benveniste, H.1    Hedlund, L.W.2    Johnson, G.A.3
  • 22
    • 0028788257 scopus 로고    scopus 로고
    • Detection of bromobenzene-induced hepatocellular necrosis using magnetic resonance microscopy, vol. 34, pp. 853-857, 1995.
    • X. Zhou, R. R. Maronpot, L. W. Hedlund, G. P. Cofer, and G. A. Johnson, "Detection of bromobenzene-induced hepatocellular necrosis using magnetic resonance microscopy, "Magn. Reson. Med., vol. 34, pp. 853-857, 1995.
    • Magn. Reson. Med.
    • Zhou, X.1    Maronpot, R.R.2    Hedlund, L.W.3    Cofer, G.P.4    Johnson, G.A.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.