1
-
-
0027445112
-
Biomechanics and biology of fracture repair under external fixation
-
Aro HT, Chao EY: Biomechanics and biology of fracture repair under external fixation. Hand Clin 9:531-542, 1993
-
(1993)
Hand Clin
, vol.9
, pp. 531-542
-
-
Aro, H.T.1
Chao, E.Y.2
-
4
-
-
0028968994
-
Contaminated fractures of the tibia: A comparison of treatment modalities in an animal model
-
Curtis MJ, Brown PR, Dick JD, et al: Contaminated fractures of the tibia: A comparison of treatment modalities in an animal model. J Orthop Res 13:286-295, 1995
-
(1995)
J Orthop Res
, vol.13
, pp. 286-295
-
-
Curtis, M.J.1
Brown, P.R.2
Dick, J.D.3
-
5
-
-
0029335492
-
Antebrachial deformities in the dog: Treatment with external fixation
-
Fox SM, Bray JC, Guerin SR, et al: Antebrachial deformities in the dog: Treatment with external fixation. J Small Anim Pract 36:315-320, 1995
-
(1995)
J Small Anim Pract
, vol.36
, pp. 315-320
-
-
Fox, S.M.1
Bray, J.C.2
Guerin, S.R.3
-
6
-
-
0028966194
-
Strength of the pin-bone interface of external fixation pins in the iliac crest: A biomechanical study
-
Liu J, Lai KA, Chou YL: Strength of the pin-bone interface of external fixation pins in the iliac crest: A biomechanical study. Clin Orthop Rel Res 10:237-244, 1995
-
(1995)
Clin Orthop Rel Res
, vol.10
, pp. 237-244
-
-
Liu, J.1
Lai, K.A.2
Chou, Y.L.3
-
9
-
-
0027603854
-
Ex vivo biomechanics of Kirschner-Ehmer external skeletal fixation applied to canine tibiae
-
Bouvy BM, Market MD, Chelikani S, et al: Ex vivo biomechanics of Kirschner-Ehmer external skeletal fixation applied to canine tibiae. Vet Surg 22:194-207, 1993
-
(1993)
Vet Surg
, vol.22
, pp. 194-207
-
-
Bouvy, B.M.1
Market, M.D.2
Chelikani, S.3
-
10
-
-
0004246716
-
-
New York, NY, McGraw-Hill
-
Beer FP, Johnston ER: Mechanics of Materials. New York, NY, McGraw-Hill, 1981, pp 150-233
-
(1981)
Mechanics of Materials
, pp. 150-233
-
-
Beer, F.P.1
Johnston, E.R.2
-
11
-
-
0030584481
-
Evaluation of cortical bone damage and axial holding power of nonthreaded and enhanced threaded pins placed with and without drilling of a pilot hole in femurs from canine cadavers
-
Anderson MA, Mann FA, Kinden DA, et al: Evaluation of cortical bone damage and axial holding power of nonthreaded and enhanced threaded pins placed with and without drilling of a pilot hole in femurs from canine cadavers. J Am Vet Med Assoc 208:883-887, 1996
-
(1996)
J Am Vet Med Assoc
, vol.208
, pp. 883-887
-
-
Anderson, M.A.1
Mann, F.A.2
Kinden, D.A.3
-
14
-
-
84995127643
-
Effect of fixation pin insertion on the bone-pin interface
-
Egger EL, Histand MB, Blass CE, et al: Effect of fixation pin insertion on the bone-pin interface. Vet Surg 15:246-252, 1986
-
(1986)
Vet Surg
, vol.15
, pp. 246-252
-
-
Egger, E.L.1
Histand, M.B.2
Blass, C.E.3
-
15
-
-
0026443395
-
Application and postoperative management of external skeletal fixators
-
Aron DN, Dewey CW: Application and postoperative management of external skeletal fixators [review]. Vet Clin North Am Small Anim Pract 22:69-97, 1992
-
(1992)
Vet Clin North Am Small Anim Pract
, vol.22
, pp. 69-97
-
-
Aron, D.N.1
Dewey, C.W.2
-
16
-
-
0025817348
-
External fixator pin insertion techniques: Biomechanical analysis and clinical relevance
-
Seitz WH Jr, Froimson AI, Brooks DB, et al: External fixator pin insertion techniques: biomechanical analysis and clinical relevance. J Hand Surg [Am] 16:560-563, 1991
-
(1991)
J Hand Surg [Am]
, vol.16
, pp. 560-563
-
-
Seitz Jr., W.H.1
Froimson, A.I.2
Brooks, D.B.3
-
17
-
-
0030279058
-
In vitro biomechanical and histological assessment of pilot hole diameter for positive-profile external skeletal fixation pins in canine tibiae
-
Roe SC, Clary EM: In vitro biomechanical and histological assessment of pilot hole diameter for positive-profile external skeletal fixation pins in canine tibiae. Vet Surg 25:453-462, 1996
-
(1996)
Vet Surg
, vol.25
, pp. 453-462
-
-
Roe, S.C.1
Clary, E.M.2
-
18
-
-
0027571816
-
A comparison of acute pull-out strength between two-way and one-way transfixation pin insertion for external skeletal fixation in canine bone
-
Dernell WS, Harari J, Blackketter DM: A comparison of acute pull-out strength between two-way and one-way transfixation pin insertion for external skeletal fixation in canine bone. Vet Surg 22:110-114, 1993
-
(1993)
Vet Surg
, vol.22
, pp. 110-114
-
-
Dernell, W.S.1
Harari, J.2
Blackketter, D.M.3
-
19
-
-
0027435284
-
Cortical bone reactions at the interface of external fixation half-pins under different loading conditions
-
Aro HT, Markel MD, Chao EY: Cortical bone reactions at the interface of external fixation half-pins under different loading conditions. J Trauma 35:776-785, 1993
-
(1993)
J Trauma
, vol.35
, pp. 776-785
-
-
Aro, H.T.1
Markel, M.D.2
Chao, E.Y.3
-
20
-
-
0000704086
-
Comparison of stainless steel versus acrylic for the connecting bar of external skeletal fixators
-
Willer RL, Egger EL, Histand MB: Comparison of stainless steel versus acrylic for the connecting bar of external skeletal fixators. J Am Anim Hosp Assoc 27:541-548, 1991
-
(1991)
J Am Anim Hosp Assoc
, vol.27
, pp. 541-548
-
-
Willer, R.L.1
Egger, E.L.2
Histand, M.B.3
-
21
-
-
0026285367
-
Biomechanical evaluation of acrylic external skeletal fixation in dogs and cats
-
Okrasinski EB, Pardo AD, Graehler RA: Biomechanical evaluation of acrylic external skeletal fixation in dogs and cats. J Am Vet Med Assoc 199:1590-1593, 1991
-
(1991)
J Am Vet Med Assoc
, vol.199
, pp. 1590-1593
-
-
Okrasinski, E.B.1
Pardo, A.D.2
Graehler, R.A.3
-
22
-
-
0026863382
-
Mechanical evaluation of half-pin (type 1) external skeletal fixation in combination with a single intramedullary pin
-
McPherron MA, Schwarz PD, Histand MB: Mechanical evaluation of half-pin (type 1) external skeletal fixation in combination with a single intramedullary pin. Vet Surg 21:178-182, 1992
-
(1992)
Vet Surg
, vol.21
, pp. 178-182
-
-
McPherron, M.A.1
Schwarz, P.D.2
Histand, M.B.3
|