메뉴 건너뛰기




Volumn 25, Issue 6, 1996, Pages 453-462

In vitro biomechanical and histological assessment of pilot hole diameter for positive-profile external skeletal fixation pins in canine tibiae

Author keywords

[No Author keywords available]

Indexed keywords

ANIMAL; ANIMAL DISEASE; ARTICLE; BIOMECHANICS; CYTOLOGY; DOG; DOG DISEASE; EQUIPMENT DESIGN; EXTERNAL FIXATOR; FRACTURE; IMAGE PROCESSING; IN VITRO STUDY; INJURY; OSTEOLYSIS; STANDARD; TIBIA;

EID: 0030279058     PISSN: 01613499     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.1532-950X.1996.tb01443.x     Document Type: Article
Times cited : (66)

References (22)
  • 1
    • 0002035044 scopus 로고
    • Experimental and clinical experience with an IM pin external skeletal fixator tie-in configuration
    • Aron DN, Foutz TL, Keller WG, et al: Experimental and clinical experience with an IM pin external skeletal fixator tie-in configuration. Vet Comp Orthop Trauma 4:86-94, 1991
    • (1991) Vet Comp Orthop Trauma , vol.4 , pp. 86-94
    • Aron, D.N.1    Foutz, T.L.2    Keller, W.G.3
  • 2
    • 0000672928 scopus 로고
    • Application of type III external fixators: A review of 23 clinical fractures in 20 dogs and two cats
    • Foland MA, Egger EL: Application of type III external fixators: A review of 23 clinical fractures in 20 dogs and two cats. J Am Anim Hosp Assoc 27:193-202, 1991
    • (1991) J Am Anim Hosp Assoc , vol.27 , pp. 193-202
    • Foland, M.A.1    Egger, E.L.2
  • 3
    • 0005605606 scopus 로고
    • Enhancing external skeletal fixation pin performance: Consideration of the pin-bone interface
    • Clary EM, Roe SC: Enhancing external skeletal fixation pin performance: Consideration of the pin-bone interface. Vet Comp Orthop Trauma 7:1-8, 1995
    • (1995) Vet Comp Orthop Trauma , vol.7 , pp. 1-8
    • Clary, E.M.1    Roe, S.C.2
  • 4
    • 84995127643 scopus 로고
    • Effect of fixation pin insertion on the bone-pin interface
    • Egger EL, Histand MB, Blass CE, et al: Effect of fixation pin insertion on the bone-pin interface. Vet Surg 15:246-252, 1986
    • (1986) Vet Surg , vol.15 , pp. 246-252
    • Egger, E.L.1    Histand, M.B.2    Blass, C.E.3
  • 5
    • 0027692020 scopus 로고
    • A Comparison of nonthreaded, enhanced threaded, and Ellis fixation pins used in type 1 external skeletal fixators in dogs
    • Anderson MA, Mann FA, Wagner-Mann C, et al: A Comparison of nonthreaded, enhanced threaded, and Ellis fixation pins used in type 1 external skeletal fixators in dogs. Vet Surg 22:482-489, 1993
    • (1993) Vet Surg , vol.22 , pp. 482-489
    • Anderson, M.A.1    Mann, F.A.2    Wagner-Mann, C.3
  • 6
    • 0023342639 scopus 로고
    • Comparison of the strength and holding power of 4 pin designs for use with half pin (type 1) external skeletal fixation
    • Bennet RA, Egger EL, Histand M, et al: Comparison of the strength and holding power of 4 pin designs for use with half pin (type 1) external skeletal fixation. Vet Surg 16:207-211, 1987
    • (1987) Vet Surg , vol.16 , pp. 207-211
    • Bennet, R.A.1    Egger, E.L.2    Histand, M.3
  • 7
    • 0027571816 scopus 로고
    • A comparison of acute pull-out strength between two-way and one-way transfixation pin insertion for external skeletal fixation in canine bone
    • Dernell WS, Harari J, Blackketter DM: A comparison of acute pull-out strength between two-way and one-way transfixation pin insertion for external skeletal fixation in canine bone. Vet Surg 22:110-114, 1993
    • (1993) Vet Surg , vol.22 , pp. 110-114
    • Dernell, W.S.1    Harari, J.2    Blackketter, D.M.3
  • 8
    • 0022634973 scopus 로고
    • An internal fixator for posterior application to short segments of the thoracic, lumbar, or lumbosacral spine
    • Krag MH, Beynnon BD, Pope MH, et al: An internal fixator for posterior application to short segments of the thoracic, lumbar, or lumbosacral spine. Clin Orthop 203:75-98, 1986
    • (1986) Clin Orthop , vol.203 , pp. 75-98
    • Krag, M.H.1    Beynnon, B.D.2    Pope, M.H.3
  • 9
    • 0024812022 scopus 로고
    • The effect of radial preload on the implant-bone interface: A cadaveric study
    • Biliouris TL, Schneider E, Rahn BA, et al: The effect of radial preload on the implant-bone interface: A cadaveric study. J Orthop Trauma 3:323-332, 1989
    • (1989) J Orthop Trauma , vol.3 , pp. 323-332
    • Biliouris, T.L.1    Schneider, E.2    Rahn, B.A.3
  • 10
    • 0015110719 scopus 로고
    • Holding characteristics of fasteners in bone
    • Bynum DJ, Ledbetter WB, Boyd CL, et al: Holding characteristics of fasteners in bone. Exp Mech 11:363-369, 1971
    • (1971) Exp Mech , vol.11 , pp. 363-369
    • Bynum, D.J.1    Ledbetter, W.B.2    Boyd, C.L.3
  • 11
    • 0027765873 scopus 로고
    • Radiographic study of homotypic variation of long bones in dogs
    • Markel MD, Sielman E: Radiographic study of homotypic variation of long bones in dogs. Am J Vet Res 54:2000-2003, 1993
    • (1993) Am J Vet Res , vol.54 , pp. 2000-2003
    • Markel, M.D.1    Sielman, E.2
  • 12
    • 0025133202 scopus 로고
    • Validity of the bulk-staining technique to separate artifactual from in vivo bone microdamage
    • Burr DB, Stafford T: Validity of the bulk-staining technique to separate artifactual from in vivo bone microdamage. Clin Orthop 260:305-308, 1990
    • (1990) Clin Orthop , vol.260 , pp. 305-308
    • Burr, D.B.1    Stafford, T.2
  • 14
    • 0015301831 scopus 로고
    • Temperatures measured in human cortical bone when drilling
    • Matthews LS, Hirsch C: Temperatures measured in human cortical bone when drilling. J Bone Joint Surg 54A:297-308, 1972
    • (1972) J Bone Joint Surg , vol.54 A , pp. 297-308
    • Matthews, L.S.1    Hirsch, C.2
  • 15
    • 0021169798 scopus 로고
    • The thermal effects of skeletal fixation-pin insertion in bone
    • Matthews LS, Green CA, Goldstein SA: The thermal effects of skeletal fixation-pin insertion in bone. J Bone Joint Surg 66A: 1077-1083, 1984
    • (1984) J Bone Joint Surg , vol.66 A , pp. 1077-1083
    • Matthews, L.S.1    Green, C.A.2    Goldstein, S.A.3
  • 16
    • 0029135259 scopus 로고
    • Thermal response and torque resistance of five cortical half-pins under simulated insertion technique
    • Wikenheiser MA, Markel MD, Lewallen DG, et al: Thermal response and torque resistance of five cortical half-pins under simulated insertion technique. J Orthop Res 13:615-619, 1995
    • (1995) J Orthop Res , vol.13 , pp. 615-619
    • Wikenheiser, M.A.1    Markel, M.D.2    Lewallen, D.G.3
  • 17
    • 0038666047 scopus 로고
    • Studies on the external fixator pin-bone interface: The effect of pin design and pin cooling in an in vivo sheep tibia model
    • Zaruby JF, Hurtig MB, Finlay JB, et al: Studies on the external fixator pin-bone interface: The effect of pin design and pin cooling in an in vivo sheep tibia model. Vet Comp Orthop Trauma 8:20-31, 1995
    • (1995) Vet Comp Orthop Trauma , vol.8 , pp. 20-31
    • Zaruby, J.F.1    Hurtig, M.B.2    Finlay, J.B.3
  • 18
    • 0023121546 scopus 로고
    • Biomechanical effects of point configuration in Kirschner-wire fixation
    • Namba RS, Kabo JM, Meals RA: Biomechanical effects of point configuration in Kirschner-wire fixation. Clin Orthop 214:19-22, 1987
    • (1987) Clin Orthop , vol.214 , pp. 19-22
    • Namba, R.S.1    Kabo, J.M.2    Meals, R.A.3
  • 19
    • 0020322562 scopus 로고
    • Thermal injury to bone: A vital-microscopic description of heat effects
    • Eriksson A, Albrektsson T, Grane B, et al: Thermal injury to bone: A vital-microscopic description of heat effects. Int J Oral Surg 11:115-121, 1982
    • (1982) Int J Oral Surg , vol.11 , pp. 115-121
    • Eriksson, A.1    Albrektsson, T.2    Grane, B.3
  • 20
  • 21
    • 0014853889 scopus 로고
    • Holding power of orthopaedic screws in bone
    • Koranyi E, Bowman CE, Knecht CD, et al: Holding power of orthopaedic screws in bone. Clin Orthop 72:283-286, 1970
    • (1970) Clin Orthop , vol.72 , pp. 283-286
    • Koranyi, E.1    Bowman, C.E.2    Knecht, C.D.3
  • 22
    • 0028538937 scopus 로고
    • Holding power of threaded external skeletal fixation pins in the near and far cortices of cadaveric canine tibiae
    • McDonald DE, Palmer RH, Hulse DA, et al: Holding power of threaded external skeletal fixation pins in the near and far cortices of cadaveric canine tibiae. Vet Surg 23:488-493, 1994
    • (1994) Vet Surg , vol.23 , pp. 488-493
    • McDonald, D.E.1    Palmer, R.H.2    Hulse, D.A.3