메뉴 건너뛰기




Volumn 79, Issue 4, 1998, Pages 319-323

Dealing with in-stent restenosis

Author keywords

[No Author keywords available]

Indexed keywords

ATHERECTOMY; INCIDENCE; PERCUTANEOUS TRANSLUMINAL ANGIOPLASTY; PRIORITY JOURNAL; RESTENOSIS; REVIEW; STENT; VEIN GRAFT;

EID: 0031966078     PISSN: 13556037     EISSN: None     Source Type: Journal    
DOI: 10.1136/hrt.79.4.319     Document Type: Review
Times cited : (36)

References (24)
  • 1
    • 0027458580 scopus 로고
    • Histology after stenting of human saphenous vein bypass grafts: Observations from surgically excised grafts 3-320 days after stent implantation
    • van Beusekom HM, van der Giessen, van Suylen R, et al. Histology after stenting of human saphenous vein bypass grafts: observations from surgically excised grafts 3-320 days after stent implantation. J Am Coll Cardiol 1993;21:45-54.
    • (1993) J Am Coll Cardiol , vol.21 , pp. 45-54
    • Van Beusekom, H.M.1    Van Der Giessen2    Van Suylen, R.3
  • 2
    • 0028051336 scopus 로고
    • Morphological characteristics of lesion formation and time course of smooth muscle cell proliferation in a porcine proliferative restenosis model
    • Carter AJ, Laird JR, Farb A, et al. Morphological characteristics of lesion formation and time course of smooth muscle cell proliferation in a porcine proliferative restenosis model. J Am Coll Cardiol 1994;24:1398-405.
    • (1994) J Am Coll Cardiol , vol.24 , pp. 1398-1405
    • Carter, A.J.1    Laird, J.R.2    Farb, A.3
  • 3
    • 0029111978 scopus 로고
    • Small stent size and intimai hyperplasia contribute to restenosis; a volumetric intravascular ultrasound analysis
    • Dussaillant GR, Mintz GS, Pichard AD, et al. Small stent size and intimai hyperplasia contribute to restenosis; a volumetric intravascular ultrasound analysis. J Am Coll Cardiol 1995;26:720-4.
    • (1995) J Am Coll Cardiol , vol.26 , pp. 720-724
    • Dussaillant, G.R.1    Mintz, G.S.2    Pichard, A.D.3
  • 4
    • 2242477091 scopus 로고
    • Use of a monoclonal antibody directed against the platelet glycoprotein IIb/IIIa receptor in high-risk coronary angioplasty
    • Califf RM, the EPIC Investigators. Use of a monoclonal antibody directed against the platelet glycoprotein IIb/IIIa receptor in high-risk coronary angioplasty. N Engl J Med 1994;330:956-61.
    • (1994) N Engl J Med , vol.330 , pp. 956-961
    • Califf, R.M.1
  • 5
    • 4243465403 scopus 로고    scopus 로고
    • Treatment of in-stent restenosis: An intravascular ultrasound study of results in 159 stented lesions
    • Mehran R, Mintz GS, Popma JJ, et al. treatment of in-stent restenosis: an intravascular ultrasound study of results in 159 stented lesions [abstract]. J Am Coll Cardiol 1997;29: 77A.
    • (1997) J Am Coll Cardiol , vol.29
    • Mehran, R.1    Mintz, G.S.2    Popma, J.J.3
  • 6
    • 0002072304 scopus 로고    scopus 로고
    • Long-term clinical and quantitative angiographic follow-up after the Palmaz-Schatz
    • Yokoi H, Kimura T, Nakagawa Y, et al. Long-term clinical and quantitative angiographic follow-up after the Palmaz-Schatz. J Am Coll Cardiol 1996;272(2 suppl A):224A.
    • (1996) J Am Coll Cardiol , vol.272 , Issue.2 SUPPL. A
    • Yokoi, H.1    Kimura, T.2    Nakagawa, Y.3
  • 7
    • 0027508929 scopus 로고
    • Management of restenosis within the Palmaz-Schatz coronary artery stent (the US multicenter experience)
    • Baim DS, Lavine MJ, Leon MB, et al. Management of restenosis within the Palmaz-Schatz coronary artery stent (the US multicenter experience). Am J Cardiol 1993;71:364-6.
    • (1993) Am J Cardiol , vol.71 , pp. 364-366
    • Baim, D.S.1    Lavine, M.J.2    Leon, M.B.3
  • 8
    • 0010540467 scopus 로고    scopus 로고
    • Is there an optimal treatment strategy for stent restenosis?
    • Tan H, Sketch MH, Tan M, et al. Is there an optimal treatment strategy for stent restenosis? [abstract] Circulation 1996;94:I-91.
    • (1996) Circulation , vol.94
    • Tan, H.1    Sketch, M.H.2    Tan, M.3
  • 9
    • 0010248894 scopus 로고    scopus 로고
    • Rotational atherectomy (RA) for in-stent restenosis (ISR): Intravascular ultrasound (IVUS) and quantitative coronary analysis (QCA)
    • Sharma S, Duvvuri S, Kakarala V, et al, Rotational atherectomy (RA) for in-stent restenosis (ISR): intravascular ultrasound (IVUS) and quantitative coronary analysis (QCA) [abstract]. Circulation 1996;94:I-454.
    • (1996) Circulation , vol.94
    • Sharma, S.1    Duvvuri, S.2    Kakarala, V.3
  • 10
    • 0001186099 scopus 로고    scopus 로고
    • Rotational atherectomy for intra-stent stenosis: Initial experience
    • Buchbinder M Goldberg SL, Fortuna RF, et al. Rotational atherectomy for intra-stent stenosis: initial experience. Circulation 1996;94:I-621.
    • (1996) Circulation , vol.94
    • Buchbinder, M.1    Goldberg, S.L.2    Fortuna, R.F.3
  • 11
    • 0029741232 scopus 로고    scopus 로고
    • Polymer coatings for stents. Can we judge a stent by its cover?
    • Fischell TA. Polymer coatings for stents. Can we judge a stent by its cover? Circulation 1996;94:1494-5.
    • (1996) Circulation , vol.94 , pp. 1494-1495
    • Fischell, T.A.1
  • 12
    • 0029761378 scopus 로고    scopus 로고
    • Marked inflammatory sequelae to implantation of biodegradable and nonbiodegradable polymers in porcine coronary arteries
    • Van der Giessen WJ, Lincoff AM, Schwanz RS, et al. Marked inflammatory sequelae to implantation of biodegradable and nonbiodegradable polymers in porcine coronary arteries. Circulation 1996;94:1690-7.
    • (1996) Circulation , vol.94 , pp. 1690-1697
    • Van Der Giessen, W.J.1    Lincoff, A.M.2    Schwanz, R.S.3
  • 13
    • 0030204650 scopus 로고    scopus 로고
    • Intravascular radiation for restenosis prevention: Could it be the holy grail?
    • King SB III. Intravascular radiation for restenosis prevention: could it be the holy grail? Heart 1996;76:99-100.
    • (1996) Heart , vol.76 , pp. 99-100
    • King III, S.B.1
  • 14
    • 0028625454 scopus 로고
    • Low dose, beta-particle emission from "stent" wires results in complete, localized inhibition of smooth muscle cell proliferation
    • Fischell TA, Kharma BK, Fischell DR, et al. Low dose, beta-particle emission from "stent" wires results in complete, localized inhibition of smooth muscle cell proliferation. Circulation 1994;90:2956-63.
    • (1994) Circulation , vol.90 , pp. 2956-2963
    • Fischell, T.A.1    Kharma, B.K.2    Fischell, D.R.3
  • 15
    • 0029120979 scopus 로고
    • Intravascular radiation before stent implantation inhibits neointimal formation in stented porcine coronary arteries
    • Waksman R, Robinson KA, Crocker IR, et al. Intravascular radiation before stent implantation inhibits neointimal formation in stented porcine coronary arteries. Circulation 1995;93:1383-6.
    • (1995) Circulation , vol.93 , pp. 1383-1386
    • Waksman, R.1    Robinson, K.A.2    Crocker, I.R.3
  • 16
    • 0029807407 scopus 로고    scopus 로고
    • Effets of endovascular radiation from a beta-particle emitting stent in a porcine coronary stenosis model. A dose response study
    • Carter AJ, Laird JR, Bailley LR, et al. Effets of endovascular radiation from a beta-particle emitting stent in a porcine coronary stenosis model. A dose response study. Circulation 1996;94:2364-8.
    • (1996) Circulation , vol.94 , pp. 2364-2368
    • Carter, A.J.1    Laird, J.R.2    Bailley, L.R.3
  • 17
    • 0030293787 scopus 로고
    • Endovascular beta-irradiation after percutaneous transluminal coronary balloon angioplasty
    • Popowski Y, Venn V, Urban P. Endovascular beta-irradiation after percutaneous transluminal coronary balloon angioplasty. Int J Radiat Oncol 1994;36:841-5.
    • (1994) Int J Radiat Oncol , vol.36 , pp. 841-845
    • Popowski, Y.1    Venn, V.2    Urban, P.3
  • 18
    • 0031005933 scopus 로고    scopus 로고
    • Catheter-based radiotherapy to inhibit restenosis after coronary stenting
    • Teirsten PS, Massuillo V, Jani S, et al. Catheter-based radiotherapy to inhibit restenosis after coronary stenting. N Engl J Med 1997;336:1697-703.
    • (1997) N Engl J Med , vol.336 , pp. 1697-1703
    • Teirsten, P.S.1    Massuillo, V.2    Jani, S.3
  • 19
    • 0030292816 scopus 로고    scopus 로고
    • High dose intracoronary radiation for inhibition of neointimal formation in the stented and balloon injured porcine models of restenosis; angiographic, morphometric, and histopathologic analyses
    • Mazur W, Ali MN, Khan MM, et al. High dose intracoronary radiation for inhibition of neointimal formation in the stented and balloon injured porcine models of restenosis; angiographic, morphometric, and histopathologic analyses. Int J Radiat Oncol 1996;36:777-88.
    • (1996) Int J Radiat Oncol , vol.36 , pp. 777-788
    • Mazur, W.1    Ali, M.N.2    Khan, M.M.3
  • 20
    • 9044251603 scopus 로고    scopus 로고
    • Heparin-coated Palmaz-Schatz stents in human coronary arteries. Early outcome of the Benestent II pilot study
    • Serruys PW, Emanuelsson H, van der Giessen W, et al. Heparin-coated Palmaz-Schatz stents in human coronary arteries. Early outcome of the Benestent II pilot study. Circulation 1996;93:412-22.
    • (1996) Circulation , vol.93 , pp. 412-422
    • Serruys, P.W.1    Emanuelsson, H.2    Van Der Giessen, W.3
  • 21
    • 0030482535 scopus 로고    scopus 로고
    • Antithrombotic potential of polymer-coated stents eluting platelet glycoprotein IIb/IIIa receptor antibody
    • Aggarwal RK, Ireland DC, Azrin MA, et al. Antithrombotic potential of polymer-coated stents eluting platelet glycoprotein IIb/IIIa receptor antibody. Circulation 1996;94: 3311-17.
    • (1996) Circulation , vol.94 , pp. 3311-3317
    • Aggarwal, R.K.1    Ireland, D.C.2    Azrin, M.A.3
  • 22
    • 0027944516 scopus 로고
    • Inhibition of integrin function by a cyclic RGD-containing peptide prevents neointima formation
    • Matsuno H, Stassen JM, Vermylen J, et al. Inhibition of integrin function by a cyclic RGD-containing peptide prevents neointima formation. Circulation 1994;90:2203-6.
    • (1994) Circulation , vol.90 , pp. 2203-2206
    • Matsuno, H.1    Stassen, J.M.2    Vermylen, J.3
  • 23
    • 0005437194 scopus 로고    scopus 로고
    • Adsorption and elution of c7E3 Fab from polymer coated stents in-vitro
    • Baron JH, Aggrawal R, de Bono DP, et al. Adsorption and elution of c7E3 Fab from polymer coated stents in-vitro [abstract]. Eur Heart J 1997;18:503.
    • (1997) Eur Heart J , vol.18 , pp. 503
    • Baron, J.H.1    Aggrawal, R.2    De Bono, D.P.3
  • 24
    • 0005442160 scopus 로고    scopus 로고
    • c7E3 Fab inhibits adhesion of smooth muscle cells to vitronectin: A possible way of inhibiting in-stent restenosis
    • Baron JH, de Bono DP, Gershlick AH. c7E3 Fab inhibits adhesion of smooth muscle cells to vitronectin: a possible way of inhibiting in-stent restenosis [abstract]. Eur Heart J 1997;18:500.
    • (1997) Eur Heart J , vol.18 , pp. 500
    • Baron, J.H.1    De Bono, D.P.2    Gershlick, A.H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.