메뉴 건너뛰기




Volumn 24, Issue 1, 1997, Pages 3-10

Tomographic imaging of the angular-dependent coherent-scatter cross section

Author keywords

bone mineral content (BMC); coherent scatter; computed tomography; material specific imaging; x ray diffraction

Indexed keywords

COHERENT SCATTERING; PHANTOMS; PIXELS; X RAY DIFFRACTION;

EID: 0031016811     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.597917     Document Type: Article
Times cited : (43)

References (16)
  • 1
    • 0026764641 scopus 로고
    • Bone composition measured by x-ray scattering
    • M. Newton, D. W. L Hukins, and G Harding,"Bone composition measured by x-ray scattering," Phys. Med. Biol. 37, 1339-1347 (1992).
    • (1992) Phys. Med. Biol. , vol.37 , pp. 1339-1347
    • Newton, M.1    Hukins, D.W.L.2    Harding, G.3
  • 2
    • 0025176990 scopus 로고
    • Energy-dispersive x-ray diffraction tomography
    • G. Harding, M. Newton, and J. Kosanetzky,"Energy-dispersive x-ray diffraction tomography," Phys. Med. Biol. 35, 33-41 (1990).
    • (1990) Phys. Med. Biol. , vol.35 , pp. 33-41
    • Harding, G.1    Newton, M.2    Kosanetzky, J.3
  • 3
    • 0019179204 scopus 로고
    • Coherent scattering and the assessment of mineral concentration in trabecular bone
    • S. A Kerr, K. Kouris, C. E. Webber, and T. J Kennett,"Coherent scattering and the assessment of mineral concentration in trabecular bone," Phys. Med. Biol. 25, 1037-1047 (1980).
    • (1980) Phys. Med. Biol. , vol.25 , pp. 1037-1047
    • Kerr, S.A.1    Kouris, K.2    Webber, C.E.3    Kennett, T.J.4
  • 4
    • 0026049510 scopus 로고
    • Coherent scattering and bone mineral measurement. The dependence of sensitivity on angle and energy
    • A. M. Ndlovu, T. J. Farrell, and C. E Webber,"Coherent scattering and bone mineral measurement. The dependence of sensitivity on angle and energy," Med. Phys. 18, 985-989 (1991)
    • (1991) Med. Phys. , vol.18 , pp. 985-989
    • Ndlovu, A.M.1    Farrell, T.J.2    Webber, C.E.3
  • 5
    • 0030059849 scopus 로고    scopus 로고
    • Angular-dependent coherent scatter measured with a diagnostic x-ray image intensifier-based imaging system
    • M. S. Westmore, A. Fenster, and I. A. Cunningham,"Angular-dependent coherent scatter measured with a diagnostic x-ray image intensifier-based imaging system," Med. Phys. 23, 723-733 (1996).
    • (1996) Med. Phys. , vol.23 , pp. 723-733
    • Westmore, M.S.1    Fenster, A.2    Cunningham, I.A.3
  • 7
    • 0023493560 scopus 로고
    • X-ray diffraction computed tomography
    • G. Harding, J. Kosanetzky, and U. Neitzel,"X-ray diffraction computed tomography," Med. Phys. 14, 515-525 (1987).
    • (1987) Med. Phys. , vol.14 , pp. 515-525
    • Harding, G.1    Kosanetzky, J.2    Neitzel, U.3
  • 8
    • 0023339707 scopus 로고
    • Status and outlook of coherent-x-ray scatter imaging
    • G. Harding and J. Kosanetzky,"Status and outlook of coherent-x-ray scatter imaging," J. Opt. Soc. Am. A 4, 933-944 (1987).
    • (1987) J. Opt. Soc. Am. A , vol.4 , pp. 933-944
    • Harding, G.1    Kosanetzky, J.2
  • 10
    • 0021151506 scopus 로고
    • Noise and contrast detection in computed tomography images
    • K. Faulkner and B. M. Moores,"Noise and contrast detection in computed tomography images," Phys. Med. Biol. 29, 329-339 (1984).
    • (1984) Phys. Med. Biol. , vol.29 , pp. 329-339
    • Faulkner, K.1    Moores, B.M.2
  • 11
    • 0018197135 scopus 로고
    • Statistical limitations in computed tomography
    • J. C. Gore and P. S. Tofts,"Statistical limitations in computed tomography," Phys. Med. Biol. 23, 1176-1182 (1978).
    • (1978) Phys. Med. Biol. , vol.23 , pp. 1176-1182
    • Gore, J.C.1    Tofts, P.S.2
  • 13
    • 0023358685 scopus 로고
    • X-ray diffraction measurements of some plastic materials and body tissues
    • J. Kosanetzky, B. Knoerr, G. Harding, and U. Neitzel,"X-ray diffraction measurements of some plastic materials and body tissues," Med. Phys 14, 526-532 (1987).
    • (1987) Med. Phys , vol.14 , pp. 526-532
    • Kosanetzky, J.1    Knoerr, B.2    Harding, G.3    Neitzel, U.4
  • 14
    • 0025756532 scopus 로고
    • Semiempirical model for generating tungsten target x-ray spectra
    • D. M. Tucker, G. T. Barnes, and D P. Chakraborty,"Semiempirical model for generating tungsten target x-ray spectra," Med. Phys. 18, 211-218 (1991).
    • (1991) Med. Phys. , vol.18 , pp. 211-218
    • Tucker, D.M.1    Barnes, G.T.2    Chakraborty, D.P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.