메뉴 건너뛰기




Volumn 213, Issue 4, 1998, Pages 207-212

Design and preliminary results of the Erlangen non-high-risk penetrating-keratoplasty study;Design und erste ergebnisse der prospektiven 'Erlanger nicht-hochrisiko- keratoplastik-studie'

Author keywords

Corneal transplantation; Immunologic graft rejection; Laser flare; Non high risk penetrating keratoplasty

Indexed keywords

CORTICOSTEROID; CYCLOSPORIN A;

EID: 0031795949     PISSN: 00232165     EISSN: None     Source Type: Journal    
DOI: 10.1055/s-2008-1034975     Document Type: Article
Times cited : (16)

References (32)
  • 1
    • 0025957690 scopus 로고
    • Corneal graft survival in HLA-A and HLA-B-matched transplantations in high-risk cases with retrospective review of HLA-DR compatibility
    • Beekhuis WH, van Rij G, Renardel de Lavalette JGC, Rinkel van Driel E, Persijn G, D'Amaro J Corneal graft survival in HLA-A and HLA-B-matched transplantations in high-risk cases with retrospective review of HLA-DR compatibility. Cornea 1991; 10:9-12
    • (1991) Cornea , vol.10 , pp. 9-12
    • Beekhuis, W.H.1    Van Rij, G.2    Renardel de Lavalette, J.G.C.3    Rinkel Van Driel, E.4    Persijn, G.5    D'Amaro, J.6
  • 5
    • 0026801355 scopus 로고
    • The collaborative corneal transplantation studies (CCTS): Effectiveness of histocompatibility matching in high-risk corneal transplantation
    • Collaborative Corneal Transplantation Studies Research Group: The collaborative corneal transplantation studies (CCTS): Effectiveness of histocompatibility matching in high-risk corneal transplantation. Arch Ophthalmol 1992; 110:1392-1403
    • (1992) Arch Ophthalmol , vol.110 , pp. 1392-1403
  • 6
    • 0024843314 scopus 로고
    • Mechanisms of corneal graft failure: The erosion of corneal privilege
    • Coster J. Mechanisms of corneal graft failure: the erosion of corneal privilege. Eye 1989; 2:251-262
    • (1989) Eye , vol.2 , pp. 251-262
    • Coster, J.1
  • 8
    • 0029065356 scopus 로고
    • Keratoplastik und Hornhautbank
    • Duncker G, Keratoplastik und Hornhautbank: Ophthalmologe 1995; 92:366-376
    • (1995) Ophthalmologe , vol.92 , pp. 366-376
    • Duncker, G.1
  • 10
    • 0017019026 scopus 로고
    • Nahttechnik bei perforierender Keratoplastik
    • Hoffmann F, Nahttechnik bei perforierender Keratoplastik. Klin Monatsbl Augenheilkd 1976; 169:584-590
    • (1976) Klin Monatsbl Augenheilkd , vol.169 , pp. 584-590
    • Hoffmann, F.1
  • 11
    • 0024328126 scopus 로고
    • Predisposing factors in corneal graft rejection
    • Hoffmann F, Pahlitzech Th. Predisposing factors in corneal graft rejection. Cornea 1989; 8:215-219
    • (1989) Cornea , vol.8 , pp. 215-219
    • Hoffmann, F.1    Pahlitzech, Th.2
  • 12
    • 0026535208 scopus 로고
    • Reproducibility of HLA-A. B and DR typing using peripheral blood samples results of retyping in the collaborative corneal transplantation studies
    • Collaborative Corneal Transplantation Studies Group (corrected) (published erratum appears in Hum Immunol 1992 Sep:35 (l):70).
    • Hopkins KA, Maguire MG. Fink NE, Bias WB. Reproducibility of HLA-A. B and DR typing using peripheral blood samples results of retyping in the collaborative corneal transplantation studies. Collaborative Corneal Transplantation Studies Group (corrected) (published erratum appears in Hum Immunol 1992 Sep:35 (l):70). Human Immunol 1992: 33 (2): 122-128
    • (1992) Human Immunol , vol.33 , Issue.2 , pp. 122-128
    • Hopkins, K.A.1    Maguire, M.G.2    Fink, N.E.3    Bias, W.B.4
  • 14
    • 0027511721 scopus 로고
    • Korrelation zwischen Tyndallometrie mit dem., Laser FlareCell Meter" in vivo und biochemischer Proteinbestimmung im menschlichen Kammerwasser
    • Küchle M, Hannappel E, Nguyen NX. Ho ST. Beck W, Naumann GOH. Korrelation zwischen Tyndallometrie mit dem., Laser FlareCell Meter" in vivo und biochemischer Proteinbestimmung im menschlichen Kammerwasser. Klin Monatsbl Augenheilkd 1993; 202:14-18
    • (1993) Klin Monatsbl Augenheilkd , vol.202 , pp. 14-18
    • Küchle, M.1    Hannappel, E.2    Nguyen, N.X.3    Ho, S.T.4    Beck, W.5    Naumann, G.O.H.6
  • 15
    • 0028215347 scopus 로고
    • Aqueous flare following penetrating keratoplasty and in corneal graft rejection
    • Küchle M, Nguyen NX, Naumann GOH. Aqueous flare following penetrating keratoplasty and in corneal graft rejection Arch Ophthalmol 1994; 112:354-358
    • (1994) Arch Ophthalmol , vol.112 , pp. 354-358
    • Küchle, M.1    Nguyen, N.X.2    Naumann, G.O.H.3
  • 16
    • 7844225805 scopus 로고
    • Quantification of aqueous flare with the Laser Flare Cell Meter following penetrating keratoplasty and in acute corneal graft rejection
    • Küchle M, Nguyen NX, Naumann GOH. Quantification of aqueous flare with the Laser Flare Cell Meter following penetrating keratoplasty and in acute corneal graft rejection. Invest Ophthalmol Vis Sci Suppl 1993; 34:1100
    • (1993) Invest Ophthalmol Vis Sci Suppl , vol.34 , pp. 1100
    • Küchle, M.1    Nguyen, N.X.2    Naumann, G.O.H.3
  • 17
    • 0032005392 scopus 로고    scopus 로고
    • Blood-aqueous barrier following mechanical or non-mechanical excimer laser trephination in penetrating keratoplasty
    • im Druck
    • Kuchle M, Nguyen NX, Seitz B, Naumann GOH. Blood-aqueous barrier following mechanical or non-mechanical excimer laser trephination in penetrating keratoplasty. Am J Ophthalmol 1998 (im Druck)
    • (1998) Am J Ophthalmol
    • Kuchle, M.1    Nguyen, N.X.2    Seitz, B.3    Naumann, G.O.H.4
  • 18
    • 0022614933 scopus 로고
    • Clinicopathologic studies of keratoplasty eyes obtained post mortem
    • Lang GK, Green WR, Maumenee AE. Clinicopathologic studies of keratoplasty eyes obtained post mortem. Am J Ophthalmol 1986; 101:28-40
    • (1986) Am J Ophthalmol , vol.101 , pp. 28-40
    • Lang, G.K.1    Green, W.R.2    Maumenee, A.E.3
  • 20
    • 0031890854 scopus 로고    scopus 로고
    • Graft decentration in penetrating keratoplasty - Non-mechanical trephination with the excimer laser 193 nm vs motor trephination
    • Langenbucher A, Seitz B, Kus MM, Naumann GOH. Graft decentration in penetrating keratoplasty - Non-mechanical trephination with the excimer laser 193 nm vs motor trephination. Ophthalmic Surg Lasers 1998; 29:106-113
    • (1998) Ophthalmic Surg Lasers , vol.29 , pp. 106-113
    • Langenbucher, A.1    Seitz, B.2    Kus, M.M.3    Naumann, G.O.H.4
  • 22
    • 0030163119 scopus 로고    scopus 로고
    • Regularität der Hornhauttopographie nach perforierender Keratoplastik - Vergleich zwischen nichtmechanischer (193 nm Excimerlaser) und mechamscher Trepanation
    • Langenbucher A, Seitz B, Kus MM, Vilchis E, Naumann GOH. Regularität der Hornhauttopographie nach perforierender Keratoplastik - Vergleich zwischen nichtmechanischer (193 nm Excimerlaser) und mechamscher Trepanation. Klin Monatsbl Augenheilkd 1996; 208:450-458
    • (1996) Klin Monatsbl Augenheilkd , vol.208 , pp. 450-458
    • Langenbucher, A.1    Seitz, B.2    Kus, M.M.3    Vilchis, E.4    Naumann, G.O.H.5
  • 23
    • 0027143917 scopus 로고
    • Excimer laser 193 nm Trepanation bei der perforierenden Keratoplastik - Bericht über die ersten 70 Patienten
    • Naumann GOH, Seitz B, Lang GK, Langenbucher A, Kus MM. Excimer laser 193 nm Trepanation bei der perforierenden Keratoplastik - Bericht über die ersten 70 Patienten. Klin Monatsbl Augenheilkd 1993; 203:252-261
    • (1993) Klin Monatsbl Augenheilkd , vol.203 , pp. 252-261
    • Naumann, G.O.H.1    Seitz, B.2    Lang, G.K.3    Langenbucher, A.4    Kus, M.M.5
  • 24
    • 0000950690 scopus 로고
    • Surgical procedures of the cornea
    • Blodi FC, Mackensen G, Neubauer H (eds.): Berlin: Springer
    • Naumann GOH, Sautter, Surgical procedures of the cornea. In: Blodi FC, Mackensen G, Neubauer H (eds.): Surgical Ophthalmology 1. Berlin: Springer. 1991
    • (1991) Surgical Ophthalmology , vol.1
    • Naumann, G.O.H.1    Sautter2
  • 25
    • 0005399949 scopus 로고
    • Excimerlaser 193 nm trephination with "orientation teeth" in penetrating keratoplasty
    • Naumann GOH, Seitz B, Excimerlaser 193 nm trephination with "orientation teeth" in penetrating keratoplasty. Ophthalmology Suppl 1992.99:122
    • (1992) Ophthalmology Suppl , vol.99 , pp. 122
    • Naumann, G.O.H.1    Seitz, B.2
  • 26
    • 0029166860 scopus 로고
    • Corneal transplantation in anterior segment deceases the Bowman Lecture (Number 56) Part II
    • Naumann GOH. Corneal transplantation in anterior segment deceases The Bowman Lecture (Number 56) Part II: Eye 1995:395-424
    • (1995) Eye , pp. 395-424
    • Naumann, G.O.H.1
  • 30
    • 0031780341 scopus 로고    scopus 로고
    • Experimental 193 nm excimer laser trephination with divergent cut angles in penetrating keratoplasty
    • irn Druck
    • Seitz B, Behrens A, Langenbucher A, Kus MM, Naumann GOH. Experimental 193 nm excimer laser trephination with divergent cut angles in penetrating keratoplasty: Cornea 1998 (irn Druck)
    • (1998) Cornea
    • Seitz, B.1    Behrens, A.2    Langenbucher, A.3    Kus, M.M.4    Naumann, G.O.H.5
  • 31
    • 0026689035 scopus 로고
    • Factors predictive of corneal graft survival. Report from the Australian corneal graft registry
    • Williams A, Roder D, Esterman A, Muehlberg SM, Coster DJ. Factors predictive of corneal graft survival. Report from the Australian corneal graft registry. Ophthalmology 1992; 99:403-414
    • (1992) Ophthalmology , vol.99 , pp. 403-414
    • Williams, A.1    Roder, D.2    Esterman, A.3    Muehlberg, S.M.4    Coster, D.J.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.