메뉴 건너뛰기




Volumn 25, Issue 11, 1998, Pages 2226-2233

Use of the fast Hartley transform for three-dimensional dose calculation in radionuclide therapy

Author keywords

[No Author keywords available]

Indexed keywords

RADIOTHERAPY;

EID: 0031795121     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.598422     Document Type: Article
Times cited : (35)

References (42)
  • 5
    • 0025144572 scopus 로고
    • Treatment planning for internal radionuclide therapy Three-dimensional dosimetry for nonuniformly distributed radionuclides
    • G. Sgouros, G. Barest, J. Thekkumthala, C. Chui, R Mohan, R E. Bigler, and P. B. Zanzonico, "Treatment planning for internal radionuclide therapy Three-dimensional dosimetry for nonuniformly distributed radionuclides," J. Nucl. Med. 31, 1884-1891 (1990).
    • (1990) J. Nucl. Med. , vol.31 , pp. 1884-1891
    • Sgouros, G.1    Barest, G.2    Thekkumthala, J.3    Chui, C.4    Mohan, R.5    Bigler, R.E.6    Zanzonico, P.B.7
  • 7
    • 0026549005 scopus 로고
    • Effects of target antigen competition on distribution of monoclonal antibody to solid tumors
    • S. J. Kennel, "Effects of target antigen competition on distribution of monoclonal antibody to solid tumors," Cancer Res. 52, 1284-1290 (1992).
    • (1992) Cancer Res. , vol.52 , pp. 1284-1290
    • Kennel, S.J.1
  • 8
    • 0027374443 scopus 로고
    • Autoradiography-based, three-dimensional calculation of dose rate for murine, human-tumor xenografts
    • K. F. Koral, C. S. Kwok, F. E. Yang, R. S. Brown, J. C. Sisson, and R. L. Wahl, "Autoradiography-based, three-dimensional calculation of dose rate for murine, human-tumor xenografts," Nucl. Med. Biol. 20, 901-909 (1993).
    • (1993) Nucl. Med. Biol. , vol.20 , pp. 901-909
    • Koral, K.F.1    Kwok, C.S.2    Yang, F.E.3    Brown, R.S.4    Sisson, J.C.5    Wahl, R.L.6
  • 9
    • 0023781556 scopus 로고
    • Direct dose confirmation of quantitative autoradiography with micro-TLD measurements for radioimmunotherapy
    • M H Griffith, E. D. Yorke, B. W. Wessels, G. L. DeNardo, and W. P. Neacey, "Direct dose confirmation of quantitative autoradiography with micro-TLD measurements for radioimmunotherapy," J. Nucl. Med. 29, 1795-1809 (1988).
    • (1988) J. Nucl. Med. , vol.29 , pp. 1795-1809
    • Griffith, M.H.1    Yorke, E.D.2    Wessels, B.W.3    DeNardo, G.L.4    Neacey, W.P.5
  • 10
    • 0028140323 scopus 로고
    • Tumor activity confirmation and isodose curve display for patients receiving 1-131-16.88 human monoclonal antibody
    • A. K. Erdi, B. Wessels, R. DeJager et al., "Tumor activity confirmation and isodose curve display for patients receiving 1-131-16.88 human monoclonal antibody," Cancer Supplement 73, 932-944 (1994).
    • (1994) Cancer Supplement , vol.73 , pp. 932-944
    • Erdi, A.K.1    Wessels, B.2    DeJager, R.3
  • 11
    • 0031054282 scopus 로고    scopus 로고
    • Implementation and evaluation of patient-specific three-dimensional internal dosimetry
    • K. S. Kolbert, G. Sgouros, A. M. Scott et al., "Implementation and evaluation of patient-specific three-dimensional internal dosimetry," J. Nucl. Med. 38, 301-308 (1997).
    • (1997) J. Nucl. Med. , vol.38 , pp. 301-308
    • Kolbert, K.S.1    Sgouros, G.2    Scott, A.M.3
  • 12
    • 0031039314 scopus 로고    scopus 로고
    • Patient-specific dosimetry using quantitative SPECT images and three-dimensional discrete Fourier transform convolution
    • G. Akabani, W. G. Hawkins, M. B. Eckblade, and P. K. Leichner, "Patient-specific dosimetry using quantitative SPECT images and three-dimensional discrete Fourier transform convolution," J. Nucl. Med. 38, 308-314 (1997).
    • (1997) J. Nucl. Med. , vol.38 , pp. 308-314
    • Akabani, G.1    Hawkins, W.G.2    Eckblade, M.B.3    Leichner, P.K.4
  • 13
    • 1842357541 scopus 로고
    • Transformation of activity distribution in quantitative SPECT to absorbed dose distribution in a radionuclide treatment planning system
    • abstract
    • M. Tagesson, M. Ljunberg, and S. E. Strand, "Transformation of activity distribution in quantitative SPECT to absorbed dose distribution in a radionuclide treatment planning system," J. Nucl. Med. 35, 123p (1994) (abstract).
    • (1994) J. Nucl. Med. , vol.35
    • Tagesson, M.1    Ljunberg, M.2    Strand, S.E.3
  • 14
    • 7844225116 scopus 로고
    • Absorbed dose averages and dose heterogeneities in radioimmunotherapy
    • E. D. Yorke, B. W. Wessels, and E W. Bradley, "Absorbed dose averages and dose heterogeneities in radioimmunotherapy," Antibody, Immunoconj Radiopharm. 4, 623-629 (1991).
    • (1991) Antibody, Immunoconj Radiopharm. , vol.4 , pp. 623-629
    • Yorke, E.D.1    Wessels, B.W.2    Bradley, E.W.3
  • 15
    • 0022885542 scopus 로고
    • Dosimetric aspects of radiolabeled antibodies for tumor therapy
    • J. L. Humm, "Dosimetric aspects of radiolabeled antibodies for tumor therapy," J. Nucl. Med. 27, 1490-1497 (1986).
    • (1986) J. Nucl. Med. , vol.27 , pp. 1490-1497
    • Humm, J.L.1
  • 17
    • 0029952594 scopus 로고    scopus 로고
    • A Monte Carlo program converting activity distributions to absorded dose distributions in a radionuclide treatment planning system
    • M. Tagesson, M. Ljungberg, and S. E. Strand, "A Monte Carlo program converting activity distributions to absorded dose distributions in a radionuclide treatment planning system," Acta Oncol. 35, 367-372 (1996).
    • (1996) Acta Oncol. , vol.35 , pp. 367-372
    • Tagesson, M.1    Ljungberg, M.2    Strand, S.E.3
  • 19
    • 0024323126 scopus 로고
    • Beta dose point kernels for radionuclides of potential use in radioimmunotherapy
    • W. V. Prestwich, J. Nunes, and C. S. Kwok, "Beta dose point kernels for radionuclides of potential use in radioimmunotherapy," J. Nucl. Med. 30, 1036-1046 (1989).
    • (1989) J. Nucl. Med. , vol.30 , pp. 1036-1046
    • Prestwich, W.V.1    Nunes, J.2    Kwok, C.S.3
  • 20
    • 0027994279 scopus 로고
    • A unified approach to photon and beta particle dosimetry
    • P. K Leichner, "A unified approach to photon and beta particle dosimetry," J. Nucl. Med. 35, 1721-1729 (1994)
    • (1994) J. Nucl. Med. , vol.35 , pp. 1721-1729
    • Leichner, P.K.1
  • 21
    • 0022502750 scopus 로고
    • Brachytherapy seed dose distribution calculation employing the fast Fourier transform
    • A. L. Boyer and E. C. Mok, "Brachytherapy seed dose distribution calculation employing the fast Fourier transform," Med. Phys. 13, 525-529 (1986).
    • (1986) Med. Phys. , vol.13 , pp. 525-529
    • Boyer, A.L.1    Mok, E.C.2
  • 23
    • 0028881834 scopus 로고
    • Development of a SPECT-based 3-D treatment planning system for radioimmunotherapy
    • H. B. Giap, D. J. Macey, D. A. Podoloff, and A. L. Boyer, "Development of a SPECT-based 3-D treatment planning system for radioimmunotherapy," J. Nucl. Med. 36, 1885-1894 (1995).
    • (1995) J. Nucl. Med. , vol.36 , pp. 1885-1894
    • Giap, H.B.1    Macey, D.J.2    Podoloff, D.A.3    Boyer, A.L.4
  • 24
    • 0000757589 scopus 로고
    • Faster than fast Fourier
    • April
    • M. A. O'Neill, "Faster than fast Fourier," BYTE April , 293-300 (1988).
    • (1988) BYTE , pp. 293-300
    • O'Neill, M.A.1
  • 25
    • 0023294326 scopus 로고
    • A three-dimensional DFT algorithm using the Fast Hartley Transform
    • H. Hao and R. N. Bracewell, "A three-dimensional DFT algorithm using the Fast Hartley Transform," Proc. IEEE 75, 264-265 (1987).
    • (1987) Proc. IEEE , vol.75 , pp. 264-265
    • Hao, H.1    Bracewell, R.N.2
  • 26
    • 0021470264 scopus 로고
    • The Fast Hartley Transform
    • R. Bracewell, "The Fast Hartley Transform," Proc. IEEE 72, 1010-1018 (1984).
    • (1984) Proc. IEEE , vol.72 , pp. 1010-1018
    • Bracewell, R.1
  • 27
    • 0024033940 scopus 로고
    • Fast Hartley Transforms for image processing
    • C. H. Paik and M. D. Fox, "Fast Hartley Transforms for image processing," IEEE Trans. Med. Imaging 7, 215-222 (1988).
    • (1988) IEEE Trans. Med. Imaging , vol.7 , pp. 215-222
    • Paik, C.H.1    Fox, M.D.2
  • 28
    • 0024701716 scopus 로고
    • Efficient realization of discrete Fourier transforms using the recursive discrete Hartley transform
    • W. C. Siu and K. L. Wong, "Efficient realization of discrete Fourier transforms using the recursive discrete Hartley transform," IEEE Proc. 136, 254-261 (1989).
    • (1989) IEEE Proc. , vol.136 , pp. 254-261
    • Siu, W.C.1    Wong, K.L.2
  • 29
    • 0027157683 scopus 로고
    • Decomposition of pencil beam kernels for fast dose calculations in three-dimensional treatment planning
    • T Bortfeld, W. Schlegel, and B. Rhein, "Decomposition of pencil beam kernels for fast dose calculations in three-dimensional treatment planning," Med. Phys. 20, 311-318 (1993).
    • (1993) Med. Phys. , vol.20 , pp. 311-318
    • Bortfeld, T.1    Schlegel, W.2    Rhein, B.3
  • 32
    • 0014251638 scopus 로고
    • Energy deposition in water by photons from point isotropic sources
    • M. J. Berger, "Energy deposition in water by photons from point isotropic sources," J. Nucl. Med. 9, 15-25 (1968).
    • (1968) J. Nucl. Med. , vol.9 , pp. 15-25
    • Berger, M.J.1
  • 33
    • 0003989121 scopus 로고
    • Oxford Science Publications Oxford Engineering Science Series 19 Clarendon Press, Oxford University Press, New York
    • R. N. Bracewell, The Hartley Transform, Oxford Science Publications Oxford Engineering Science Series 19 (Clarendon Press, Oxford University Press, New York, 1986).
    • (1986) The Hartley Transform
    • Bracewell, R.N.1
  • 35
    • 0028751054 scopus 로고
    • Use of the Fast Hartley Transform for efficient 3D convolution in calculation of radiation dose
    • Baltimore, MD
    • A. K. Erdi, M. Loew, E. Yorke et al., "Use of the Fast Hartley Transform for efficient 3D convolution in calculation of radiation dose," Proceedings of the 16th Annual IEEE-EMBS Conference, Baltimore, MD, 1994, pp 639-640.
    • (1994) Proceedings of the 16th Annual IEEE-EMBS Conference , pp. 639-640
    • Erdi, A.K.1    Loew, M.2    Yorke, E.3
  • 36
    • 33744568726 scopus 로고
    • Three dimensional dose rate calculation from bone marrow autoradiographs for a patient treated with Re-186 labeled monoclonal antibody
    • abstract
    • A. K. Erdi, M. Sarfaraz, B. W. Wessels et al., "Three dimensional dose rate calculation from bone marrow autoradiographs for a patient treated with Re-186 labeled monoclonal antibody," J. Immunother. 16, 168 (1994) (abstract).
    • (1994) J. Immunother. , vol.16 , pp. 168
    • Erdi, A.K.1    Sarfaraz, M.2    Wessels, B.W.3
  • 37
    • 0002055540 scopus 로고
    • Discrete radioisotope sources
    • edited by G. J. Hine and G N. Braumwell Academic, New York, NY
    • R. Loevinger, E. M. Japha, and G. L. Brownell, "Discrete radioisotope sources," in Radiation Dosimetry, edited by G. J. Hine and G N. Braumwell (Academic, New York, NY, 1956), pp. 693-799.
    • (1956) Radiation Dosimetry , pp. 693-799
    • Loevinger, R.1    Japha, E.M.2    Brownell, G.L.3
  • 38
    • 85027232966 scopus 로고    scopus 로고
    • MIRD Pamphlet No. 17: The dosimetry of nonuniform activity distributions - Radionuclide S values at the voxel level
    • accepted for publication
    • J. S. Roberson, W. E. Bolch, L. G. Bouchet et al., "MIRD Pamphlet No. 17: The dosimetry of nonuniform activity distributions - Radionuclide S values at the voxel level," accepted for publication in J. Nucl. Med.
    • J. Nucl. Med.
    • Roberson, J.S.1    Bolch, W.E.2    Bouchet, L.G.3
  • 39
    • 0000663435 scopus 로고
    • Estimation of absorbed doses in radioimmunotherapy
    • L. E Williams, "Estimation of absorbed doses in radioimmunotherapy," Med. Phys. 22, 958 (1995).
    • (1995) Med. Phys. , vol.22 , pp. 958
    • Williams, L.E.1
  • 40
    • 85027229183 scopus 로고    scopus 로고
    • Mabdose 1: Characterization of a general purpose dosimetry code
    • submitted for publication
    • T. K. Johnson, D. McCLure and S. McCourt, "Mabdose 1: Characterization of a general purpose dosimetry code," submitted for publication in Med. Phys.
    • Med. Phys.
    • Johnson, T.K.1    McClure, D.2    McCourt, S.3
  • 41
    • 0029788687 scopus 로고    scopus 로고
    • A Monte Carlo approach to patient-specific dosimetry
    • E. E. Furhang, C S. Chui, and G Sgouros, "A Monte Carlo approach to patient-specific dosimetry," Med. Phys. 23, 1523-1529 (1996).
    • (1996) Med. Phys. , vol.23 , pp. 1523-1529
    • Furhang, E.E.1    Chui, C.S.2    Sgouros, G.3
  • 42
    • 0030796876 scopus 로고    scopus 로고
    • Implementation of a Monte Carlo dosimetry method for patient-specific internal emitter therapy
    • E E. Furhang, C. S. Chui, K S. Kolbert, S. M. Larson, and G. Sgouros, "Implementation of a Monte Carlo dosimetry method for patient-specific internal emitter therapy," Med. Phys 24, 1163-1172 (1997).
    • (1997) Med. Phys , vol.24 , pp. 1163-1172
    • Furhang, E.E.1    Chui, C.S.2    Kolbert, K.S.3    Larson, S.M.4    Sgouros, G.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.