Volumn 38, Issue 2, 1997, Pages 301-308

Implementation and evaluation of patient-specific three-dimensional internal dosimetry

Author keywords

dose volume histograms; radionuclide therapy; three dimensional dosimetry

Indexed keywords

RADIOISOTOPE;

EID: 0031054282     PISSN: 01615505     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (113)

References (29)
  • 1
    • 0003216348 scopus 로고
    • "S," absorbed dose per unit cumulated activity for selected radionuclides and organs
    • New York: Society of Nuclear Medicine
    • Snyder WS, Ford MR, Warner GG, Watson EB. "S," absorbed dose per unit cumulated activity for selected radionuclides and organs. MIRD Pamphlet No. 11. New York: Society of Nuclear Medicine; 1975.
    • (1975) MIRD Pamphlet No. 11
    • Snyder, W.S.1    Ford, M.R.2    Warner, G.G.3    Watson, E.B.4
  • 2
    • 0013183732 scopus 로고
    • Estimates of specific absorbed fractions for photon sources uniformly distributed in various organs of a heterogeneous phantom
    • New York: Society of Nuclear Medicine
    • Snyder WS, Ford MR, Warner GG. Estimates of specific absorbed fractions for photon sources uniformly distributed in various organs of a heterogeneous phantom. MIRD Pamphlet No. 5, Revised. New York: Society of Nuclear Medicine; 1978.
    • (1978) MIRD Pamphlet No. 5, Revised
    • Snyder, W.S.1    Ford, M.R.2    Warner, G.G.3
  • 4
    • 0027204708 scopus 로고
    • Tumor dosimetry in radioimmunotherapy: Methods of calculation for beta particles
    • Leichner PK, Kwok CS. Tumor dosimetry in radioimmunotherapy: methods of calculation for beta particles. Med Phys 1993;20:529-534.
    • (1993) Med Phys , vol.20 , pp. 529-534
    • Leichner, P.K.1    Kwok, C.S.2
  • 6
    • 0030002992 scopus 로고    scopus 로고
    • MIRDOSE - The personal computer software for internal dose assessment in nuclear medicine
    • Stabin MG. MIRDOSE - the personal computer software for internal dose assessment in nuclear medicine. J Nucl Med 1996;37:538-546.
    • (1996) J Nucl Med , vol.37 , pp. 538-546
    • Stabin, M.G.1
  • 7
    • 0024078324 scopus 로고
    • MABDOS: A generalized program for internal radionuclide dosimetry
    • Johnson TK. MABDOS: a generalized program for internal radionuclide dosimetry. Comput Methods Programs Biomed 1988;27:159-167.
    • (1988) Comput Methods Programs Biomed , vol.27 , pp. 159-167
    • Johnson, T.K.1
  • 8
    • 0027225966 scopus 로고
    • Three-dimensional dosimetry for radioimmunotherapy treatment planning
    • Sgouros G, Chiu S, Pentlow KS, et al. Three-dimensional dosimetry for radioimmunotherapy treatment planning. J Nucl Med 1993;34:1595-1601.
    • (1993) J Nucl Med , vol.34 , pp. 1595-1601
    • Sgouros, G.1    Chiu, S.2    Pentlow, K.S.3
  • 9
    • 0028140323 scopus 로고
    • Tumor activity confirmation and isodose curve display for patients receiving iodine-131-labeled 16.88 human monoclonal antibody
    • Erdi AK, Wessels BW, DeJager R, et al. Tumor activity confirmation and isodose curve display for patients receiving iodine-131-labeled 16.88 human monoclonal antibody. Cancer 1994;73:(suppl):932-944.
    • (1994) Cancer , vol.73 , Issue.SUPPL. , pp. 932-944
    • Erdi, A.K.1    Wessels, B.W.2    DeJager, R.3
  • 10
    • 0025144572 scopus 로고
    • Treatment planning for internal radionuclide therapy: Three-dimensional dosimetry for nonuniformly distributed radionuclides
    • Sgouros G, Barest G, Thekkumthala J, et al. Treatment planning for internal radionuclide therapy: three-dimensional dosimetry for nonuniformly distributed radionuclides. J Nucl Med 1990;31:1884-1891.
    • (1990) J Nucl Med , vol.31 , pp. 1884-1891
    • Sgouros, G.1    Barest, G.2    Thekkumthala, J.3
  • 11
    • 0028946465 scopus 로고
    • Validation of a dose-point kernel convolution technique for internal dosimetry
    • Giap HB, Macey DJ, Bayouth JE, Boyer AL. Validation of a dose-point kernel convolution technique for internal dosimetry. Phys Med Biol 1995;40:365-381.
    • (1995) Phys Med Biol , vol.40 , pp. 365-381
    • Giap, H.B.1    Macey, D.J.2    Bayouth, J.E.3    Boyer, A.L.4
  • 12
    • 0028881834 scopus 로고
    • Development of a SPECT-based three-dimensional treatment planning system for radioimmunotherapy
    • Giap HB, Macey DJ, Podoloff DA. Development of a SPECT-based three-dimensional treatment planning system for radioimmunotherapy. J Nucl Med 1995;36:1885-1894.
    • (1995) J Nucl Med , vol.36 , pp. 1885-1894
    • Giap, H.B.1    Macey, D.J.2    Podoloff, D.A.3
  • 13
    • 1842357541 scopus 로고
    • Transformation of activity distribution in quantitative SPECT to absorbed dose distribution in a radionuclide treatment planning system
    • Tagesson M, Ljungberg M, Strand SE. Transformation of activity distribution in quantitative SPECT to absorbed dose distribution in a radionuclide treatment planning system [Abstract]. J Nucl Med 1994;123P.
    • (1994) J Nucl Med
    • Tagesson, M.1    Ljungberg, M.2    Strand, S.E.3
  • 14
    • 0029788687 scopus 로고    scopus 로고
    • A Monte Carlo approach to patient-specific dosimetry
    • Furhang EE, Chui CS, Sgouros G. A Monte Carlo approach to patient-specific dosimetry. Med Phys 1996;23:1523-1529.
    • (1996) Med Phys , vol.23 , pp. 1523-1529
    • Furhang, E.E.1    Chui, C.S.2    Sgouros, G.3
  • 15
    • 0026941844 scopus 로고
    • Validation of the distance histogram technique for three-dimensional and two-dimensional dosimetric calculations
    • van Dieren EB, van Lingen A, Roos JC, Teule GJJ. Validation of the distance histogram technique for three-dimensional and two-dimensional dosimetric calculations. Appl Rad Isot 1992;43:1211-1221.
    • (1992) Appl Rad Isot , vol.43 , pp. 1211-1221
    • Van Dieren, E.B.1    Van Lingen, A.2    Roos, J.C.3    Teule, G.J.J.4
  • 16
    • 0005713849 scopus 로고
    • Dose-volume histogram representation of patient dose distribution in three-dimensional internal dosimetry
    • Kolbert KS, Sgouros G, Scott AM, et al. Dose-volume histogram representation of patient dose distribution in three-dimensional internal dosimetry [Abstract]. J Nucl Med 1994;35:123P.
    • (1994) J Nucl Med , vol.35
    • Kolbert, K.S.1    Sgouros, G.2    Scott, A.M.3
  • 19
    • 0029946917 scopus 로고    scopus 로고
    • Radionuclide photon dose kernels for internal emitter dosimetry
    • Furhang EE, Sgouros G, Chui CS. Radionuclide photon dose kernels for internal emitter dosimetry. Med Phys 1996;23:759-765.
    • (1996) Med Phys , vol.23 , pp. 759-765
    • Furhang, E.E.1    Sgouros, G.2    Chui, C.S.3
  • 20
    • 0024323126 scopus 로고
    • Beta dose point kernels for radionuclides of potential use in radioimmunotherapy
    • Prestwich WV, Nunes J, Kwok CS. Beta dose point kernels for radionuclides of potential use in radioimmunotherapy. J Nucl Med 1989;30:1036-1046.
    • (1989) J Nucl Med , vol.30 , pp. 1036-1046
    • Prestwich, W.V.1    Nunes, J.2    Kwok, C.S.3
  • 21
    • 0025307874 scopus 로고
    • EGS4 monte carlo determination of the beta dose kernel in water
    • Simpkin DJ, Mackie TR. EGS4 monte carlo determination of the beta dose kernel in water. Med Phys 1990;17:179-186.
    • (1990) Med Phys , vol.17 , pp. 179-186
    • Simpkin, D.J.1    Mackie, T.R.2
  • 22
    • 0027994279 scopus 로고
    • A unified approach to photon and beta particle dosimetry
    • Leichner PK. A unified approach to photon and beta particle dosimetry. J Nucl Med 1994;35:1721-1729.
    • (1994) J Nucl Med , vol.35 , pp. 1721-1729
    • Leichner, P.K.1
  • 25
    • 0028231359 scopus 로고
    • A phase I B trial of humanized monoclonal antibody M195 (anti-CD33) in myeloid leukemia: Specific targeting without immunogenicity
    • Caron PC, Jurcic JG, Scott AM, et al. A phase I B trial of humanized monoclonal antibody M195 (anti-CD33) in myeloid leukemia: specific targeting without immunogenicity. Blood 1994;83:1760-1768.
    • (1994) Blood , vol.83 , pp. 1760-1768
    • Caron, P.C.1    Jurcic, J.G.2    Scott, A.M.3
  • 28
    • 0028947670 scopus 로고
    • Phase I radioimmunotherapy trial with iodine-131-CC49 in metastatic colon carcinoma
    • Divgi CR, Scott AM, Dantis L, et al. Phase I radioimmunotherapy trial with iodine-131-CC49 in metastatic colon carcinoma. J Nucl Med 1995;36:586-592.
    • (1995) J Nucl Med , vol.36 , pp. 586-592
    • Divgi, C.R.1    Scott, A.M.2    Dantis, L.3
  • 29
    • 0028338372 scopus 로고
    • Clinical applications of fusion imaging in oncology
    • Scott AM, Macapinlac H, Zhang JJ, et al. Clinical applications of fusion imaging in oncology. Nucl Med Biol 1994;21:775-784.
    • (1994) Nucl Med Biol , vol.21 , pp. 775-784
    • Scott, A.M.1    Macapinlac, H.2    Zhang, J.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.