메뉴 건너뛰기




Volumn 80, Issue 5, 1998, Pages 493-498

Coronary flow reserve in the contralateral artery increases after successful coronary angioplasty in patients with spontaneously visible collateral vessels

Author keywords

Angioplasty; Contralateral coronary artery; Coronary flow reserve

Indexed keywords

ADULT; AGED; ARTICLE; BLOOD FLOW VELOCITY; CLINICAL ARTICLE; CONTROLLED STUDY; CORONARY ARTERY BLOOD FLOW; CORONARY ARTERY COLLATERAL CIRCULATION; CORONARY ARTERY OBSTRUCTION; FEMALE; HUMAN; MALE; POSTOPERATIVE PERIOD; PRIORITY JOURNAL; TRANSLUMINAL CORONARY ANGIOPLASTY; TREATMENT OUTCOME;

EID: 0031760584     PISSN: 13556037     EISSN: None     Source Type: Journal    
DOI: 10.1136/hrt.80.5.493     Document Type: Article
Times cited : (6)

References (17)
  • 1
    • 0027219114 scopus 로고
    • Alteration in regulation of myocardial blood flow in one-vessel coronary artery disease determined by positron emission tomography
    • Sambuceti G, Parodi O, Marcassa C, et al. Alteration in regulation of myocardial blood flow in one-vessel coronary artery disease determined by positron emission tomography. Am J Cardiol 1993;72:538-43.
    • (1993) Am J Cardiol , vol.72 , pp. 538-543
    • Sambuceti, G.1    Parodi, O.2    Marcassa, C.3
  • 2
    • 0027248553 scopus 로고
    • Altered coronary vasodilator reserve and metabolism in myocardium subtended by normal arteries in patients with coronary artery disease
    • Uren GN, Marraccini P, Gistri R, et al. Altered coronary vasodilator reserve and metabolism in myocardium subtended by normal arteries in patients with coronary artery disease. J Am Coll Cardiol 1993;22:650-8.
    • (1993) J Am Coll Cardiol , vol.22 , pp. 650-658
    • Uren, G.N.1    Marraccini, P.2    Gistri, R.3
  • 3
    • 0025965439 scopus 로고
    • Modulation of coronary vasomotor tone in humans: Progressive endothelial dysfunction with different early stages of coronary atherosclerosis
    • Zeiher AM, Drexler H, Wollschlager H, et al. Modulation of coronary vasomotor tone in humans: progressive endothelial dysfunction with different early stages of coronary atherosclerosis. Circulation 1991;83:391-401.
    • (1991) Circulation , vol.83 , pp. 391-401
    • Zeiher, A.M.1    Drexler, H.2    Wollschlager, H.3
  • 4
    • 0026515443 scopus 로고
    • Pathophysiological consequences of atherosclerosis extend into the coronary microcirculation: Restoration of endothelium-dependent responses by L arginine
    • Kuo L, Davis MJ, Cannon S, et al. Pathophysiological consequences of atherosclerosis extend into the coronary microcirculation: restoration of endothelium-dependent responses by L arginine. Circ Res 1992;70:465-76.
    • (1992) Circ Res , vol.70 , pp. 465-476
    • Kuo, L.1    Davis, M.J.2    Cannon, S.3
  • 5
    • 0027449411 scopus 로고
    • Accuracy of electronic digital callipers compared with quantitative angiography in measuring coronary arterial diameter
    • Uehata A, Matsuguchi T, Bittl JA, et al. Accuracy of electronic digital callipers compared with quantitative angiography in measuring coronary arterial diameter. Circulation 1993;88:724-9.
    • (1993) Circulation , vol.88 , pp. 724-729
    • Uehata, A.1    Matsuguchi, T.2    Bittl, J.A.3
  • 6
    • 0021923120 scopus 로고
    • Changes in collateral channel filling immediately after controlled coronary artery occlusion by an angioplasty balloon in human subjects
    • Rentrop KP, Cohen M, Blanke H, et al. Changes in collateral channel filling immediately after controlled coronary artery occlusion by an angioplasty balloon in human subjects. J Am Coll Cardiol 1985;5:587-92.
    • (1985) J Am Coll Cardiol , vol.5 , pp. 587-592
    • Rentrop, K.P.1    Cohen, M.2    Blanke, H.3
  • 7
    • 0026504959 scopus 로고
    • Validation of a Doppler guide wire for intravascular measurement of coronary artery flow velocity
    • Doucette JW, Corl DP, Payne HP, et al. Validation of a Doppler guide wire for intravascular measurement of coronary artery flow velocity. Circulation 1992;85:1899-911.
    • (1992) Circulation , vol.85 , pp. 1899-1911
    • Doucette, J.W.1    Corl, D.P.2    Payne, H.P.3
  • 8
    • 0029143257 scopus 로고
    • Vein plasma endothelin-1 and cyclic GMP increase during coronary angioplasty is related to myocardial ischemia
    • Kyriakides ZS, Markianos M, Iliodromitis EK, et al. Vein plasma endothelin-1 and cyclic GMP increase during coronary angioplasty is related to myocardial ischemia. Eur Heart J 1995;16:894-8.
    • (1995) Eur Heart J , vol.16 , pp. 894-898
    • Kyriakides, Z.S.1    Markianos, M.2    Iliodromitis, E.K.3
  • 9
    • 0025785630 scopus 로고
    • Intravenous adenosine: Continuous infusion and low dose bolus administration for determination of coronary vasodilator reserve in patients with and without coronary artery disease
    • Kern M, Deligonul U, Tatineri S, et al. Intravenous adenosine: continuous infusion and low dose bolus administration for determination of coronary vasodilator reserve in patients with and without coronary artery disease. J Am Call Cardiol 1991;18:718-29.
    • (1991) J Am Call Cardiol , vol.18 , pp. 718-729
    • Kern, M.1    Deligonul, U.2    Tatineri, S.3
  • 10
    • 0028182651 scopus 로고
    • Correlation of pharmacological Tc-99m sestamibi myocardial perfusion imaging with poststenotic coronary flow reserve in patients with angiographically intermediate coronary artery stenoses
    • Miller D, Donohue T, Younis L, et al. Correlation of pharmacological Tc-99m sestamibi myocardial perfusion imaging with poststenotic coronary flow reserve in patients with angiographically intermediate coronary artery stenoses. Circulation 1994;89:2150-60.
    • (1994) Circulation , vol.89 , pp. 2150-2160
    • Miller, D.1    Donohue, T.2    Younis, L.3
  • 11
    • 0028145316 scopus 로고
    • Intracoronary Doppler guide wire versus stress single-photon emission computed tomographic thallium-201 imaging in assessment of intermediate coronary stenosis
    • Joye J, Schulman D, Lasorda D, et al. Intracoronary Doppler guide wire versus stress single-photon emission computed tomographic thallium-201 imaging in assessment of intermediate coronary stenosis. J Am Coll Cardiol 1994;24:940-7.
    • (1994) J Am Coll Cardiol , vol.24 , pp. 940-947
    • Joye, J.1    Schulman, D.2    Lasorda, D.3
  • 12
    • 0028265856 scopus 로고
    • Effects of heart rate on phasic coronary blood flow pattern and flow reserve in patients with normal coronary arteries: A study with an intravascular Doppler catheter and spectral analysis
    • Hongo M, Nakatsuka T, Watanabe N, et al. Effects of heart rate on phasic coronary blood flow pattern and flow reserve in patients with normal coronary arteries: a study with an intravascular Doppler catheter and spectral analysis. Am Heart J 1994;127:545-51.
    • (1994) Am Heart J , vol.127 , pp. 545-551
    • Hongo, M.1    Nakatsuka, T.2    Watanabe, N.3
  • 13
    • 0022384824 scopus 로고
    • Platelets, endothelium, and vasospasm
    • Vanhoutte P, Houston D. Platelets, endothelium, and vasospasm. Circulation 1985;72:728-34.
    • (1985) Circulation , vol.72 , pp. 728-734
    • Vanhoutte, P.1    Houston, D.2
  • 14
    • 0023875978 scopus 로고
    • The effect of coronary angioplasty on coronary flow reserve
    • Wilson RF, Johnson MR, Marcus ML, et al. The effect of coronary angioplasty on coronary flow reserve. Circulation 1988;77:873-85.
    • (1988) Circulation , vol.77 , pp. 873-885
    • Wilson, R.F.1    Johnson, M.R.2    Marcus, M.L.3
  • 15
    • 0026637436 scopus 로고
    • Alterations of phasic coronary artery flow velocity in humans during percutaneous coronary angioplasty
    • Segal J, Kern MJ, Scott NA, et al. Alterations of phasic coronary artery flow velocity in humans during percutaneous coronary angioplasty. J Am Coll Cardiol 1992;20:276-86.
    • (1992) J Am Coll Cardiol , vol.20 , pp. 276-286
    • Segal, J.1    Kern, M.J.2    Scott, N.A.3
  • 16
    • 0030970596 scopus 로고    scopus 로고
    • Role of coronary artery lumen enlargement in improving coronary blood flow after balloon angioplasty and stenting: A combined intravascular ultrasound Doppler flow and imaging study
    • Kern MJ, Dupouy P, Drury JH, et al. Role of coronary artery lumen enlargement in improving coronary blood flow after balloon angioplasty and stenting: a combined intravascular ultrasound Doppler flow and imaging study. J Am Coll Cardiol 1997;29:1520-7.
    • (1997) J Am Coll Cardiol , vol.29 , pp. 1520-1527
    • Kern, M.J.1    Dupouy, P.2    Drury, J.H.3
  • 17
    • 0025277969 scopus 로고
    • Interstudy variability of coronary flow reserve. Influence of heart rate, arterial pressure, and ventricular preload
    • McGinn AL, White CW, Wilson RF. Interstudy variability of coronary flow reserve. Influence of heart rate, arterial pressure, and ventricular preload. Circulation 1990;81: 1319-30.
    • (1990) Circulation , vol.81 , pp. 1319-1330
    • McGinn, A.L.1    White, C.W.2    Wilson, R.F.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.