메뉴 건너뛰기




Volumn 3, Issue 4, 1998, Pages 221-225

Ambulatory blood pressure monitoring: Test reproducibility and its implications

Author keywords

Ambulatory blood pressure; Antihypertensive drugs; Blood pressure monitoring; Hypertension; Reproducibility; Variability of blood pressure; White coat hypertension

Indexed keywords

ACCURACY; AMBULATORY MONITORING; AROUSAL; BLOOD PRESSURE; BLOOD PRESSURE MONITORING; CARDIOVASCULAR RISK; CIRCADIAN RHYTHM; DRUG DEVELOPMENT; ECHOCARDIOGRAPHY; ELECTROCARDIOGRAPHY; HEART ARRHYTHMIA; HEART LEFT VENTRICLE WALL; MEDICAL DECISION MAKING; MOVEMENT (PHYSIOLOGY); NOISE; PRIORITY JOURNAL; REPRODUCIBILITY; REVIEW; SLEEP; THICKNESS; VIBRATION; WHITE COAT HYPERTENSION;

EID: 0031744680     PISSN: 13595237     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Review
Times cited : (16)

References (57)
  • 1
    • 0000516777 scopus 로고
    • Portable blood pressure recorder: Accuracy and preliminary use in evaluating intradaily variations in blood pressure
    • Hinman AT, Engel BT, Bickford AF. Portable blood pressure recorder: accuracy and preliminary use in evaluating intradaily variations in blood pressure. Am Heart J 1962; 63:663-668.
    • (1962) Am Heart J , vol.63 , pp. 663-668
    • Hinman, A.T.1    Engel, B.T.2    Bickford, A.F.3
  • 3
    • 1642412322 scopus 로고
    • A validation study of the del Mar Avionics ambulatory blood pressure system
    • Harsfield GA, Pickering TG, Laragh JH. A validation study of the Del Mar Avionics ambulatory blood pressure system. Ambulat Electrocardiol 1979; 1:7-12.
    • (1979) Ambulat Electrocardiol , vol.1 , pp. 7-12
    • Harsfield, G.A.1    Pickering, T.G.2    Laragh, J.H.3
  • 5
    • 0021281140 scopus 로고
    • The circadian blood pressure pattern in ambulatory normal subjects
    • Weber MA, Drayer Jl, Nakamura DK, Wyle FA. The circadian blood pressure pattern in ambulatory normal subjects. Am J Cardiol 1984; 54:115-119.
    • (1984) Am J Cardiol , vol.54 , pp. 115-119
    • Weber, M.A.1    Drayer, Jl.2    Nakamura, D.K.3    Wyle, F.A.4
  • 7
    • 0028818147 scopus 로고
    • State of the market. A review of ambulatory blood pressure monitoring devices
    • O'Brien E, Atkins N, Staessen J. State of the market. A review of ambulatory blood pressure monitoring devices. Hypertension 1995; 26:835-842.
    • (1995) Hypertension , vol.26 , pp. 835-842
    • O'Brien, E.1    Atkins, N.2    Staessen, J.3
  • 8
    • 0027479012 scopus 로고
    • National standard for measurement of resting and ambulatory blood pressures with automated sphygmomanometers
    • White WB, Berson AS, Robbins C, Jamieson MJ, Prisant LM, Rocoella E, et al. National standard for measurement of resting and ambulatory blood pressures with automated sphygmomanometers. Hypertension 1993; 21:504-509.
    • (1993) Hypertension , vol.21 , pp. 504-509
    • White, W.B.1    Berson, A.S.2    Robbins, C.3    Jamieson, M.J.4    Prisant, L.M.5    Rocoella, E.6
  • 9
    • 0003473365 scopus 로고
    • Arlington, VA: Association for the Advancement of Medical Instrumentation
    • Association for the Advancement of Medical Instrumentation. American national standard for electronic or automated sphygmomanometers. Arlington, VA: Association for the Advancement of Medical Instrumentation; 1992. p. 40.
    • (1992) American National Standard for Electronic or Automated Sphygmomanometers , pp. 40
  • 10
    • 0025071770 scopus 로고
    • The British Hypertension Society protocol for the evaluation of automated and semi-automated blood pressure measuring devices with special reference to ambulatory systems
    • O'Brien E, Petrie J, Littler W, de Swiet M, Padfield PL, O'Malley K, et al. The British Hypertension Society protocol for the evaluation of automated and semi-automated blood pressure measuring devices with special reference to ambulatory systems. J Hypertens 1990; 8:607-619.
    • (1990) J Hypertens , vol.8 , pp. 607-619
    • O'Brien, E.1    Petrie, J.2    Littler, W.3    De Swiet, M.4    Padfield, P.L.5    O'Malley, K.6
  • 11
    • 0020680727 scopus 로고
    • BP as a determinant of cardiac left ventricular mass
    • Drayer JIM, Weber MA, DeYoung JL. BP as a determinant of cardiac left ventricular mass. Arch Intern Med 1983; 143:90-92.
    • (1983) Arch Intern Med , vol.143 , pp. 90-92
    • Drayer, J.I.M.1    Weber, M.A.2    DeYoung, J.L.3
  • 12
    • 0024423194 scopus 로고
    • Assessment of the daily blood pressure load as a determinant of cardiac function in patients with mild-to-moderate hypertension
    • White WB, Dey HM, Schulman P. Assessment of the daily blood pressure load as a determinant of cardiac function in patients with mild-to-moderate hypertension. Am Heart J 1989; 118:782-795.
    • (1989) Am Heart J , vol.118 , pp. 782-795
    • White, W.B.1    Dey, H.M.2    Schulman, P.3
  • 13
    • 0025151158 scopus 로고
    • Risk stratification of left ventricular hypertrophy in systemic hypertension using noninvasive ambulatory blood pressure monitoring
    • Verdecchia P, Schillaci G, Boldrini F, Guerrieri M, Gatteschi C, Benemio G, et al. Risk stratification of left ventricular hypertrophy in systemic hypertension using noninvasive ambulatory blood pressure monitoring. Am J Cardiol 1990; 66:583-590.
    • (1990) Am J Cardiol , vol.66 , pp. 583-590
    • Verdecchia, P.1    Schillaci, G.2    Boldrini, F.3    Guerrieri, M.4    Gatteschi, C.5    Benemio, G.6
  • 14
    • 0020592231 scopus 로고
    • Left ventricular hypertrophy in patients with hypertension: Importance of blood pressure response to regularly recurring stress
    • Devereux RB, Pickering TG, Harshfield GA, Kleinert HD, Deby L, Clark L, et al. Left ventricular hypertrophy in patients with hypertension: importance of blood pressure response to regularly recurring stress. Circulation 1983; 68:470-476.
    • (1983) Circulation , vol.68 , pp. 470-476
    • Devereux, R.B.1    Pickering, T.G.2    Harshfield, G.A.3    Kleinert, H.D.4    Deby, L.5    Clark, L.6
  • 15
    • 0023805573 scopus 로고
    • Correlation of office and ambulatory blood pressure measurements with urinary albumin and N-acetyl-beta-D-glucosaminidase excretions in essential hypertension
    • Opsahl JA, Abraham PA, Halstenson CE, Keane WF. Correlation of office and ambulatory blood pressure measurements with urinary albumin and N-acetyl-beta-D-glucosaminidase excretions in essential hypertension. Am J Hypertens 1988; 1 (suppl 3 Pt 3):117S-120S.
    • (1988) Am J Hypertens , vol.1 , Issue.3 SUPPL. AND PART
    • Opsahl, J.A.1    Abraham, P.A.2    Halstenson, C.E.3    Keane, W.F.4
  • 16
    • 0024580705 scopus 로고
    • Microalbuminuria and casual and ambulatory blood pressure monitoring in normotensives and in patients with borderline and mild essential hypertension
    • Giaconi S, Levanti C, Fommei E, Innocenti F, Seghieri G, Palla L, et al. Microalbuminuria and casual and ambulatory blood pressure monitoring in normotensives and in patients with borderline and mild essential hypertension. Am J Hypertens 1989; 2:259-261.
    • (1989) Am J Hypertens , vol.2 , pp. 259-261
    • Giaconi, S.1    Levanti, C.2    Fommei, E.3    Innocenti, F.4    Seghieri, G.5    Palla, L.6
  • 17
    • 0025647266 scopus 로고
    • Silent cerebrovascular disease in the elderly. Correlation with ambulatory pressure
    • Shimada K, Kawamoto A, Matsubayashi K, Ozawa T. Silent cerebrovascular disease in the elderly. Correlation with ambulatory pressure. Hypertension 1990; 16:692-699.
    • (1990) Hypertension , vol.16 , pp. 692-699
    • Shimada, K.1    Kawamoto, A.2    Matsubayashi, K.3    Ozawa, T.4
  • 18
    • 0023934566 scopus 로고
    • Arterial distensibility and ambulatory blood pressure monitoring in essential hypertension
    • Asmar RG, Brunel PC, Pannier BM, Lacolley PJ, Safar SE. Arterial distensibility and ambulatory blood pressure monitoring in essential hypertension. Am J Cardiol 1988; 61:1066-1070.
    • (1988) Am J Cardiol , vol.61 , pp. 1066-1070
    • Asmar, R.G.1    Brunel, P.C.2    Pannier, B.M.3    Lacolley, P.J.4    Safar, S.E.5
  • 19
    • 0025273923 scopus 로고
    • Ambulatory blood pressure monitoring and echocardiographic left ventricular wall thickness and mass
    • Prisant LM, Carr AA. Ambulatory blood pressure monitoring and echocardiographic left ventricular wall thickness and mass. Am J Hypertens 1990; 3:81-89.
    • (1990) Am J Hypertens , vol.3 , pp. 81-89
    • Prisant, L.M.1    Carr, A.A.2
  • 20
    • 0026625416 scopus 로고
    • Clinical utility of ambulatory blood pressure monitoring in target organ complications and equipment choices
    • Prisant LM, Bottini PB, Carr A. Clinical utility of ambulatory blood pressure monitoring in target organ complications and equipment choices. J Clin Pharmacol 1992; 32:620-626.
    • (1992) J Clin Pharmacol , vol.32 , pp. 620-626
    • Prisant, L.M.1    Bottini, P.B.2    Carr, A.3
  • 23
    • 0030047350 scopus 로고    scopus 로고
    • Nocturnal fall of blood pressure and silent cerebrovascular damage in elderly hypertensive patients. Advanced silent cerebrovascular damage in extreme dippers
    • Kario K, Matsuo T, Kobayashi H, Imiya M, Matsuo M, Shimada K. Nocturnal fall of blood pressure and silent cerebrovascular damage in elderly hypertensive patients. Advanced silent cerebrovascular damage in extreme dippers. Hypertension 1996; 27:130-135.
    • (1996) Hypertension , vol.27 , pp. 130-135
    • Kario, K.1    Matsuo, T.2    Kobayashi, H.3    Imiya, M.4    Matsuo, M.5    Shimada, K.6
  • 24
    • 0023644390 scopus 로고
    • Effect of antihypertensive therapy on the circadian blood pressure pattern
    • Weber MA, Tonkon MJ, Klein RC. Effect of antihypertensive therapy on the circadian blood pressure pattern. Am J Med 1987; 82:50-52.
    • (1987) Am J Med , vol.82 , pp. 50-52
    • Weber, M.A.1    Tonkon, M.J.2    Klein, R.C.3
  • 25
    • 0025152189 scopus 로고
    • Documentation of the effective length of action of antihypertensive treatment
    • Weber MA. Documentation of the effective length of action of antihypertensive treatment. Am J Cardiol 1990; 66 (suppl 9): 43C-48C.
    • (1990) Am J Cardiol , vol.66 , Issue.9 SUPPL.
    • Weber, M.A.1
  • 26
    • 0026059881 scopus 로고
    • Once-daily verapamil in the treatment of mild-to-moderate hypertension: A double-blind placebo-controlled dose-ranging study
    • Carr AA, Bottini PB, Prisant LM, Fisher LD, Devane JG, O'Brien DE, et al. Once-daily verapamil in the treatment of mild-to-moderate hypertension: a double-blind placebo-controlled dose-ranging study. J Clin Pharmacol 1991; 31:144-150.
    • (1991) J Clin Pharmacol , vol.31 , pp. 144-150
    • Carr, A.A.1    Bottini, P.B.2    Prisant, L.M.3    Fisher, L.D.4    Devane, J.G.5    O'Brien, D.E.6
  • 27
    • 0026560410 scopus 로고
    • Effectiveness of once-daily monotherapy with a new nifedipine sustained release calcium antagonist
    • Carr AA, Bottini PB, Feig P, Prisant LM, Mulligan S, Devane JG, et al. Effectiveness of once-daily monotherapy with a new nifedipine sustained release calcium antagonist. Am J Cardiol 1992; 69:28E-32E.
    • (1992) Am J Cardiol , vol.69
    • Carr, A.A.1    Bottini, P.B.2    Feig, P.3    Prisant, L.M.4    Mulligan, S.5    Devane, J.G.6
  • 28
    • 0026294655 scopus 로고
    • Ambulatory blood pressure monitoring in the design of antihypertensive drug trials
    • Conway J, Coats AJ. Ambulatory blood pressure monitoring in the design of antihypertensive drug trials. J Hypertens 1991; 9 (suppl 8): S57-S58.
    • (1991) J Hypertens , vol.9 , Issue.8 SUPPL.
    • Conway, J.1    Coats, A.J.2
  • 29
    • 0001564717 scopus 로고    scopus 로고
    • Benefits of ambulatory blood pressure monitoring in the design of antihypertensive drug trials
    • Coats AJS. Benefits of ambulatory blood pressure monitoring in the design of antihypertensive drug trials. Blood Press Monit 1996; 1:157-160.
    • (1996) Blood Press Monit , vol.1 , pp. 157-160
    • Coats, A.J.S.1
  • 31
    • 0026598459 scopus 로고
    • Differing perspectives on white coat hypertension
    • Pickering TG. Differing perspectives on white coat hypertension. Arch Intern Med 1992; 152:691-692.
    • (1992) Arch Intern Med , vol.152 , pp. 691-692
    • Pickering, T.G.1
  • 32
    • 0023000456 scopus 로고
    • Assessment of patients with office hypertension by 24-hour noninvasive ambulatory blood pressure monitoring
    • White WB. Assessment of patients with office hypertension by 24-hour noninvasive ambulatory blood pressure monitoring. Arch Intern Med 1986; 146:2196-2199.
    • (1986) Arch Intern Med , vol.146 , pp. 2196-2199
    • White, W.B.1
  • 33
    • 0025666434 scopus 로고
    • 'White coat' versus 'sustained' borderline hypertension in Tecumseh, Michigan
    • Julius S, Mejia A, Jones K, Krause L, Schork N, van de Ven C, et al. 'White coat' versus 'sustained' borderline hypertension in Tecumseh, Michigan. Hypertension 1990; 16:617-623.
    • (1990) Hypertension , vol.16 , pp. 617-623
    • Julius, S.1    Mejia, A.2    Jones, K.3    Krause, L.4    Schork, N.5    Van De Ven, C.6
  • 34
    • 0024990717 scopus 로고
    • Blood pressure reactivity predicts myocardial infarction among treated hypertensive patients
    • Alderman MH, Ooi WL, Madhavan S, Cohen H. Blood pressure reactivity predicts myocardial infarction among treated hypertensive patients. J Clin Epidemiol 1990; 43:859-866.
    • (1990) J Clin Epidemiol , vol.43 , pp. 859-866
    • Alderman, M.H.1    Ooi, W.L.2    Madhavan, S.3    Cohen, H.4
  • 35
    • 0028019533 scopus 로고
    • Diagnosis of mild hypertension by ambulatory blood pressure monitoring
    • Weber MA, Neutel JM, Smith DHG, Graettinger WF. Diagnosis of mild hypertension by ambulatory blood pressure monitoring. Circulation 1994; 90:2291-2298.
    • (1994) Circulation , vol.90 , pp. 2291-2298
    • Weber, M.A.1    Neutel, J.M.2    Smith, D.H.G.3    Graettinger, W.F.4
  • 36
    • 0030573803 scopus 로고    scopus 로고
    • White-coat hypertension as a cause of cardiovascular dysfunction
    • Glen SK, Elliott HL, Curzio JL, Les KR, Reid JL. White-coat hypertension as a cause of cardiovascular dysfunction. Lancet 1996; 348:654-657.
    • (1996) Lancet , vol.348 , pp. 654-657
    • Glen, S.K.1    Elliott, H.L.2    Curzio, J.L.3    Les, K.R.4    Reid, J.L.5
  • 37
    • 0025064672 scopus 로고
    • National High Blood Pressure Education Program Working Group report on ambulatory blood pressure monitoring
    • National High Blood Pressure Education Program Working Group report on ambulatory blood pressure monitoring. Arch Intern Med 1990; 150:2270-2280.
    • (1990) Arch Intern Med , vol.150 , pp. 2270-2280
  • 38
    • 0027210887 scopus 로고
    • Automated ambulatory blood pressure and self-measured blood pressure monitoring devices: Their role in the diagnosis and management of hypertension
    • American College of Physicians. Automated ambulatory blood pressure and self-measured blood pressure monitoring devices: their role in the diagnosis and management of hypertension. Ann Intern Med 1993; 118:889-892.
    • (1993) Ann Intern Med , vol.118 , pp. 889-892
  • 40
    • 0030066412 scopus 로고
    • American Society of Hypertension ad hoc panel. Recommendations for the use of home (self) and ambulatory blood pressure monitoring
    • Pickering TG, Kaplan NM, Krakoff L, Prisant LM, Sheps S, Weber MA, et al. American Society of Hypertension ad hoc panel. Recommendations for the use of home (self) and ambulatory blood pressure monitoring. Am J Hypertens 1995; 9:1-11.
    • (1995) Am J Hypertens , vol.9 , pp. 1-11
    • Pickering, T.G.1    Kaplan, N.M.2    Krakoff, L.3    Prisant, L.M.4    Sheps, S.5    Weber, M.A.6
  • 41
    • 0025821558 scopus 로고
    • Mechanical trauma and acute neuralgia associated with automated ambulatory blood pressure monitoring
    • Bottini PB, Rhoades RB, Carr AA, Prisant LM. Mechanical trauma and acute neuralgia associated with automated ambulatory blood pressure monitoring [letter]. Am J Hypertens 1991; 4:288.
    • (1991) Am J Hypertens , vol.4 , pp. 288
    • Bottini, P.B.1    Rhoades, R.B.2    Carr, A.A.3    Prisant, L.M.4
  • 42
    • 0028576510 scopus 로고
    • A complication of ambulatory blood pressure monitoring
    • Baetz MD, Pylypcuk G, Baetz M. A complication of ambulatory blood pressure monitoring. Ann Intern Med 1994; 121:468-469.
    • (1994) Ann Intern Med , vol.121 , pp. 468-469
    • Baetz, M.D.1    Pylypcuk, G.2    Baetz, M.3
  • 43
    • 0024277970 scopus 로고
    • Adverse events associated with 24-hour ambulatory sphygmomanometry
    • Burris JF, Brinkley RR, Riggs MC, Mroczek WJ. Adverse events associated with 24-hour ambulatory sphygmomanometry. JAMA 1988; 260:2508-2509.
    • (1988) JAMA , vol.260 , pp. 2508-2509
    • Burris, J.F.1    Brinkley, R.R.2    Riggs, M.C.3    Mroczek, W.J.4
  • 44
    • 0022150324 scopus 로고
    • Phlebitis associated with noninvasive 24-hour ambulatory blood pressure monitor
    • Creevy PC, Burris JF, Mroczek WJ. Phlebitis associated with noninvasive 24-hour ambulatory blood pressure monitor. JAMA 1985; 254:2411.
    • (1985) JAMA , vol.254 , pp. 2411
    • Creevy, P.C.1    Burris, J.F.2    Mroczek, W.J.3
  • 45
    • 0022430412 scopus 로고
    • The Rumpel-Leede sign associated with a noninvasive ambulatory blood pressure monitoring
    • White WB. The Rumpel-Leede sign associated with a noninvasive ambulatory blood pressure monitoring. JAMA 1985; 253:1724.
    • (1985) JAMA , vol.253 , pp. 1724
    • White, W.B.1
  • 47
    • 0026515869 scopus 로고
    • Effect on sleep - But not on blood pressure -of nocturnal non-invasive blood pressure monitoring
    • Schwan A, Eriksson G. Effect on sleep - but not on blood pressure -of nocturnal non-invasive blood pressure monitoring. J Hypertens 1992; 10:189-194.
    • (1992) J Hypertens , vol.10 , pp. 189-194
    • Schwan, A.1    Eriksson, G.2
  • 48
    • 0027058399 scopus 로고
    • Limited reproducibility of hourly blood pressure values obtained by ambulatory blood pressure monitoring: Implications for studies on hypertensive drugs
    • Mancia G, Omboni S, Parati G, Trazzi S, Mutti E. Limited reproducibility of hourly blood pressure values obtained by ambulatory blood pressure monitoring: implications for studies on hypertensive drugs. J Hypertens 1992; 10:1531-1535.
    • (1992) J Hypertens , vol.10 , pp. 1531-1535
    • Mancia, G.1    Omboni, S.2    Parati, G.3    Trazzi, S.4    Mutti, E.5
  • 49
    • 0001586101 scopus 로고    scopus 로고
    • Reproducibility of ambulatory blood pressure monitoring
    • Musso NR, Lotti G. Reproducibility of ambulatory blood pressure monitoring. Blood Press Monit 1996; 1:105-109.
    • (1996) Blood Press Monit , vol.1 , pp. 105-109
    • Musso, N.R.1    Lotti, G.2
  • 50
    • 0030865822 scopus 로고    scopus 로고
    • Ambulatory blood pressure monitoring: How reproducible is it?
    • Musso NR, Vegassola C, Barone C, Lotti G. Ambulatory blood pressure monitoring: how reproducible is it? Am J Hypertens 1997; 10:936-939.
    • (1997) Am J Hypertens , vol.10 , pp. 936-939
    • Musso, N.R.1    Vegassola, C.2    Barone, C.3    Lotti, G.4
  • 51
    • 0022259222 scopus 로고
    • Reproducibility of blood pressures in normotensive subjects
    • Drayer JIM, Weber MA. Reproducibility of blood pressures in normotensive subjects. Clin Exp Hypertens 1985; 7:417-422.
    • (1985) Clin Exp Hypertens , vol.7 , pp. 417-422
    • Drayer, J.I.M.1    Weber, M.A.2
  • 52
    • 0021264726 scopus 로고
    • Ambulatory blood pressure recordings. Reproducibility and unpredictability
    • des Combes BJ, Porchet M, Waeber B, Brunner HR. Ambulatory blood pressure recordings. Reproducibility and unpredictability. Hypertension 1984; 6:C110-C114.
    • (1984) Hypertension , vol.6
    • Des Combes, B.J.1    Porchet, M.2    Waeber, B.3    Brunner, H.R.4
  • 53
    • 0029930895 scopus 로고    scopus 로고
    • Ambulatory blood pressure monitoring: Methodologic issues
    • Prisant LM, Bottini PB, Carr AA. Ambulatory blood pressure monitoring: methodologic issues. Am J Nephrol 1996; 16:190-201.
    • (1996) Am J Nephrol , vol.16 , pp. 190-201
    • Prisant, L.M.1    Bottini, P.B.2    Carr, A.A.3
  • 54
    • 0028787759 scopus 로고
    • Ambulatory blood pressure monitoring in the diagnosis of hypertension
    • Prisant LM. Ambulatory blood pressure monitoring in the diagnosis of hypertension. Cardiol Clin 1995; 13:479-490.
    • (1995) Cardiol Clin , vol.13 , pp. 479-490
    • Prisant, L.M.1
  • 56
    • 0026689248 scopus 로고
    • Sex, cardiac hypertrophy and diurnal blood pressure variations in essential hypertension
    • Verdecchia P, Schillaci G, Boldrini F, Guerrieri M, Porcellati C. Sex, cardiac hypertrophy and diurnal blood pressure variations in essential hypertension. J Hypertens 1992; 10:683-692.
    • (1992) J Hypertens , vol.10 , pp. 683-692
    • Verdecchia, P.1    Schillaci, G.2    Boldrini, F.3    Guerrieri, M.4    Porcellati, C.5
  • 57
    • 0023237973 scopus 로고
    • A quantitative analysis of the effects of activity and time of day on the diurnal variations of blood pressure
    • Clark LA, Denby L, Pregibon D, Harshfield GA, Pickering TG, Blank S, et al. A quantitative analysis of the effects of activity and time of day on the diurnal variations of blood pressure. J Chron Dis 1987; 40:671-681.
    • (1987) J Chron Dis , vol.40 , pp. 671-681
    • Clark, L.A.1    Denby, L.2    Pregibon, D.3    Harshfield, G.A.4    Pickering, T.G.5    Blank, S.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.