메뉴 건너뛰기




Volumn 21, Issue 6, 1998, Pages 459-463

Does coronary stenting following balloon angioplasty improve myocardial fractional flow reserve?

Author keywords

Adenosine 5' triphosphate; Coronary artery disease; Coronary stenting

Indexed keywords

ADULT; AGED; ANGIOCARDIOGRAPHY; ARTICLE; CLINICAL ARTICLE; CORONARY ARTERY BLOOD FLOW; CORONARY ARTERY OBSTRUCTION; CORONARY ARTERY PRESSURE; FEMALE; HEART MUSCLE BLOOD FLOW; HUMAN; MALE; PERCUTANEOUS TRANSLUMINAL ANGIOPLASTY; PRIORITY JOURNAL; STENT;

EID: 0031741890     PISSN: 01741551     EISSN: None     Source Type: Journal    
DOI: 10.1007/s002709900304     Document Type: Article
Times cited : (1)

References (12)
  • 2
    • 0024560324 scopus 로고
    • Impaired coronary vasodilator reserve in the immediate postcoronary angioplasty period: Analysis of coronary artery flow velocity indexes and regional cardiac venous efflux
    • Kern MJ, Deligonul U, Vandormael M, Labovitz A, Gudipati CV, Gabliani G, Bodet J, Shah Y, Kennedy HL (1989) Impaired coronary vasodilator reserve in the immediate postcoronary angioplasty period: Analysis of coronary artery flow velocity indexes and regional cardiac venous efflux. J Am Coll Cardiol 13:860-872
    • (1989) J Am Coll Cardiol , vol.13 , pp. 860-872
    • Kern, M.J.1    Deligonul, U.2    Vandormael, M.3    Labovitz, A.4    Gudipati, C.V.5    Gabliani, G.6    Bodet, J.7    Shah, Y.8    Kennedy, H.L.9
  • 4
    • 0000638007 scopus 로고
    • Does adjunct coronary stenting in comparison to balloon angioplasty have an impact on Doppler flow velocity parameters?
    • Haude M, Baumgart D, Caspari G, Erbel R (1995) Does adjunct coronary stenting in comparison to balloon angioplasty have an impact on Doppler flow velocity parameters? (abstract) Circulation 92 [Suppl I]:I-547
    • (1995) Circulation , vol.92 , Issue.1 SUPPL.
    • Haude, M.1    Baumgart, D.2    Caspari, G.3    Erbel, R.4
  • 6
    • 0027401951 scopus 로고
    • Experimental basis of determining maximum coronary, myocardial, and collateral blood flow by pressure measurements for assessing functional stenosis severity before and after percutaneous transluminal coronary angioplasty
    • Pijls NH, van Son JA, Kirkeeide RL, De Bruyne B, Gould KL (1993) Experimental basis of determining maximum coronary, myocardial, and collateral blood flow by pressure measurements for assessing functional stenosis severity before and after percutaneous transluminal coronary angioplasty. Circulation 87:1354-1367
    • (1993) Circulation , vol.87 , pp. 1354-1367
    • Pijls, N.H.1    Van Son, J.A.2    Kirkeeide, R.L.3    De Bruyne, B.4    Gould, K.L.5
  • 7
    • 0028806554 scopus 로고
    • Fractional flow reserve: A useful index to evaluate the influence of an epicardial coronary stenosis on myocardial blood flow
    • Pijls NH, Van Gelder B, Van der Voort P, Peels K, Bracke FA, Bonnier HJ, el Gamal MI (1995) Fractional flow reserve: A useful index to evaluate the influence of an epicardial coronary stenosis on myocardial blood flow. Circulation 92:3183-3193
    • (1995) Circulation , vol.92 , pp. 3183-3193
    • Pijls, N.H.1    Van Gelder, B.2    Van Der Voort, P.3    Peels, K.4    Bracke, F.A.5    Bonnier, H.J.6    El Gamal, M.I.7
  • 10
    • 0029841529 scopus 로고    scopus 로고
    • Simultaneous coronary pressure and flow velocity measurements in humans: Feasibility, reproducibility, and hemodynamic dependence of coronary flow velocity reserve, hyperemic flow versus pressure slope index, and fractional flow reserve
    • De Bruyne B, Bartunek J, Sys SU, Pijls NH, Heyndrickx GR, Wijns W (1996) Simultaneous coronary pressure and flow velocity measurements in humans: Feasibility, reproducibility, and hemodynamic dependence of coronary flow velocity reserve, hyperemic flow versus pressure slope index, and fractional flow reserve. Circulation 94:1843-1849
    • (1996) Circulation , vol.94 , pp. 1843-1849
    • De Bruyne, B.1    Bartunek, J.2    Sys, S.U.3    Pijls, N.H.4    Heyndrickx, G.R.5    Wijns, W.6
  • 11
    • 0029118617 scopus 로고
    • Quantitative coronary angiography in predicting functional significance of stenoses in an unselected patient cohort
    • Bartunek J, Sys SU, Heyndrickx GR, Pijls NH, De Bruyne B (1995) Quantitative coronary angiography in predicting functional significance of stenoses in an unselected patient cohort. J Am Coll Cardiol 26:328-334
    • (1995) J Am Coll Cardiol , vol.26 , pp. 328-334
    • Bartunek, J.1    Sys, S.U.2    Heyndrickx, G.R.3    Pijls, N.H.4    De Bruyne, B.5
  • 12
    • 0030884584 scopus 로고    scopus 로고
    • From research to clinical practice: Current role of intracoronary physiologically based decision making in the cardiac catheterization laboratory
    • Kern MJ, De Bruyne B, Pijls NH (1997) From research to clinical practice: Current role of intracoronary physiologically based decision making in the cardiac catheterization laboratory. J Am Coll Cardiol 30:613-620
    • (1997) J Am Coll Cardiol , vol.30 , pp. 613-620
    • Kern, M.J.1    De Bruyne, B.2    Pijls, N.H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.