메뉴 건너뛰기




Volumn 40, Issue 4, 1998, Pages 559-570

Characterization of flow emerging from a stenosis using MRI

Author keywords

Shear boundary reattachment, RUFIS; Stenotic flow; Ultra fast imaging

Indexed keywords

MAGNETIC RESONANCE IMAGING; REYNOLDS NUMBER; TURBULENT FLOW;

EID: 0031682696     PISSN: 07403194     EISSN: None     Source Type: Journal    
DOI: 10.1002/mrm.1910400409     Document Type: Article
Times cited : (21)

References (37)
  • 1
    • 0022686199 scopus 로고
    • High-speed spiral-scan echo planar NMR imaging
    • C. B. Ahn, J. H. Kim, Z. H. Cho, High-speed spiral-scan echo planar NMR imaging. IEEE Trans. Med. Imaging MI-5, 2-7 (1986).
    • (1986) IEEE Trans. Med. Imaging , vol.MI-5 , pp. 2-7
    • Ahn, C.B.1    Kim, J.H.2    Cho, Z.H.3
  • 3
    • 7344220845 scopus 로고
    • A new nuclear magnetic resonance imaging technique for unambiguous unidirectional measurement of flow velocity
    • Z. H. Cho, C. H. Oh, Y. S. Kim, C. W. Mun, O. Nalcioglu, S. J. Lee, M. K. Chung, A new nuclear magnetic resonance imaging technique for unambiguous unidirectional measurement of flow velocity, J. Appl. Physics 60, 1256-1262 (1986).
    • (1986) J. Appl. Physics , vol.60 , pp. 1256-1262
    • Cho, Z.H.1    Oh, C.H.2    Kim, Y.S.3    Mun, C.W.4    Nalcioglu, O.5    Lee, S.J.6    Chung, M.K.7
  • 4
    • 0023462722 scopus 로고
    • Evaluation of steady and pulsatile flow with dynamic MRI using limited flip angles and gradient refocused echoes
    • A. J. Evans, L. W. Hedlund, R. J. Herkens, J. A. Utz, E. K. Fram, R. A. Blinder, Evaluation of steady and pulsatile flow with dynamic MRI using limited flip angles and gradient refocused echoes, Magn. Reson. Imaging 5, 475-482 (1987).
    • (1987) Magn. Reson. Imaging , vol.5 , pp. 475-482
    • Evans, A.J.1    Hedlund, L.W.2    Herkens, R.J.3    Utz, J.A.4    Fram, E.K.5    Blinder, R.A.6
  • 6
    • 0023203564 scopus 로고
    • MR vascular imaging with a fast gradient refocusing pulse sequence and reformatted images from transaxial sections
    • G. T. Gullberg, F. W. Wehrli, A. Shimakawa, M. A. Simons, MR vascular imaging with a fast gradient refocusing pulse sequence and reformatted images from transaxial sections, Radiology 165, 241-246 (1987).
    • (1987) Radiology , vol.165 , pp. 241-246
    • Gullberg, G.T.1    Wehrli, F.W.2    Shimakawa, A.3    Simons, M.A.4
  • 7
    • 0025160052 scopus 로고
    • The application of phase shifts in NMR for flow measurement
    • D. N. Firmin, G. Nayler, P. Kilner, D. B. Longmore, The application of phase shifts in NMR for flow measurement, Magn. Reson. Med. 14, 230-241 (1990).
    • (1990) Magn. Reson. Med. , vol.14 , pp. 230-241
    • Firmin, D.N.1    Nayler, G.2    Kilner, P.3    Longmore, D.B.4
  • 8
    • 0023007579 scopus 로고
    • Magnetic resonance angiography
    • C. L. Dumoulin, H. R. Hart, Magnetic resonance angiography, Radiology 161, 717-720 (1986).
    • (1986) Radiology , vol.161 , pp. 717-720
    • Dumoulin, C.L.1    Hart, H.R.2
  • 9
    • 84985818135 scopus 로고
    • Quantitative NMR imaging of flow
    • J. M. Pope, S. Yao, Quantitative NMR imaging of flow, Concepts Magn. Reson. 5, 281-302 (1993).
    • (1993) Concepts Magn. Reson. , vol.5 , pp. 281-302
    • Pope, J.M.1    Yao, S.2
  • 10
    • 84910330083 scopus 로고
    • Measurement of flow characteristics using nuclear magnetic resonance
    • Radiology Research and Education Foundation, San Francisco
    • M. A. Hemminga, Measurement of flow characteristics using nuclear magnetic resonance, in "Biomedical Magnetic Resonance," pp. 157-184, Radiology Research and Education Foundation, San Francisco, 1984.
    • (1984) Biomedical Magnetic Resonance , pp. 157-184
    • Hemminga, M.A.1
  • 11
    • 0015650235 scopus 로고
    • Flow characteristics in models of arterial stenoses - I. Steady flow
    • D. F. Young, F. Y. Tsai, Flow characteristics in models of arterial stenoses - I. Steady flow, J. Biomech. 6, 395-410 (1973).
    • (1973) J. Biomech. , vol.6 , pp. 395-410
    • Young, D.F.1    Tsai, F.Y.2
  • 12
    • 0017096726 scopus 로고    scopus 로고
    • Flow patterns in stenotic blood vessel models
    • T. Azuma, T. Fukushima, Flow patterns in stenotic blood vessel models, Biorheology 13, 337-355 (1996).
    • (1996) Biorheology , vol.13 , pp. 337-355
    • Azuma, T.1    Fukushima, T.2
  • 13
    • 0016091584 scopus 로고
    • Experimental measurements of turbulence spectra distal to stenoses
    • B. M. Kim, W. H. Corcoran, Experimental measurements of turbulence spectra distal to stenoses, J. Biomech. 7, 335-342 (1974).
    • (1974) J. Biomech. , vol.7 , pp. 335-342
    • Kim, B.M.1    Corcoran, W.H.2
  • 14
    • 0027814380 scopus 로고
    • Application of the method of singularities for evaluation of turbulent jet-type boundary layer flow
    • A. Y. Tkachuk, Application of the method of singularities for evaluation of turbulent jet-type boundary layer flow, Heat Transfer Res. 25, 102-108 (1993).
    • (1993) Heat Transfer Res. , vol.25 , pp. 102-108
    • Tkachuk, A.Y.1
  • 15
    • 7344248475 scopus 로고
    • Simulation of a round turbulent jet by using the method of discrete vortices
    • S. M. Belotserkovskii, A. S. Ginevskii, N. N. Khlapov, Simulation of a round turbulent jet by using the method of discrete vortices, Dokl. Physics 40, 642-645 (1995).
    • (1995) Dokl. Physics , vol.40 , pp. 642-645
    • Belotserkovskii, S.M.1    Ginevskii, A.S.2    Khlapov, N.N.3
  • 16
    • 0018503772 scopus 로고
    • Fluid mechanics of arterial stenoses
    • D. F. Young, Fluid mechanics of arterial stenoses, J. Biomech. Eng. 101, 157-175 (1979).
    • (1979) J. Biomech. Eng. , vol.101 , pp. 157-175
    • Young, D.F.1
  • 17
    • 0024060147 scopus 로고
    • Velocity profiles in stenosed tube models using magnetic resonance imaging
    • S. E. Rittgers, D-Y. Fei, K. A. Kraft, P. P. Fatouros, P. R. S. Kishore, Velocity profiles in stenosed tube models using magnetic resonance imaging, Trans. ASME 110, 180-184 (1988).
    • (1988) Trans. ASME , vol.110 , pp. 180-184
    • Rittgers, S.E.1    Fei, D.-Y.2    Kraft, K.A.3    Fatouros, P.P.4    Kishore, P.R.S.5
  • 18
    • 0026023195 scopus 로고
    • Appearance of poststenotic jets in MRI: Dependence on flow velocity and on imaging parameters
    • R. P. Spielmann, O. Schneider, F. Thiele, M. Heller, E. Bucheler, Appearance of poststenotic jets in MRI: dependence on flow velocity and on imaging parameters, Magn. Reson. Imaging 9, 67-72 (1991).
    • (1991) Magn. Reson. Imaging , vol.9 , pp. 67-72
    • Spielmann, R.P.1    Schneider, O.2    Thiele, F.3    Heller, M.4    Bucheler, E.5
  • 19
    • 0026601498 scopus 로고
    • Visualization and quantification of blood flow by magnetic resonance imaging
    • P. Boesiger, S. E. Maier, L. Kecheng, M. B. Scheidegger, D. Meier, Visualization and quantification of blood flow by magnetic resonance imaging, J. Biomech. 25, 55-67 (1992).
    • (1992) J. Biomech. , vol.25 , pp. 55-67
    • Boesiger, P.1    Maier, S.E.2    Kecheng, L.3    Scheidegger, M.B.4    Meier, D.5
  • 20
    • 0026892557 scopus 로고
    • Comparison of velocity-encoded MR imaging and fluid dynamic modeling of steady and disturbed flow
    • Y. Sun, D. O. Hearshen, G. W. Rankin, A. M. Haggar, Comparison of velocity-encoded MR imaging and fluid dynamic modeling of steady and disturbed flow, J. Magn. Reson. Imaging 2, 443-452 (1992).
    • (1992) J. Magn. Reson. Imaging , vol.2 , pp. 443-452
    • Sun, Y.1    Hearshen, D.O.2    Rankin, G.W.3    Haggar, A.M.4
  • 21
    • 0029099442 scopus 로고
    • Ultra-fast imaging using low flip angles and FIDs
    • D. P. Madio, I. J. Lowe, Ultra-fast imaging using low flip angles and FIDs, Magn. Reson. Med. 34, 525-529 (1995).
    • (1995) Magn. Reson. Med. , vol.34 , pp. 525-529
    • Madio, D.P.1    Lowe, I.J.2
  • 22
    • 0031953920 scopus 로고    scopus 로고
    • Ultra-fast velocity imaging in stenotically-produced turbulent jets using RUFIS
    • D. P. Madio, H. M. Gach, I. J. Lowe, Ultra-fast velocity imaging in stenotically-produced turbulent jets using RUFIS, Magn. Reson. Med. 39, 574-580 (1998).
    • (1998) Magn. Reson. Med. , vol.39 , pp. 574-580
    • Madio, D.P.1    Gach, H.M.2    Lowe, I.J.3
  • 26
    • 0022367617 scopus 로고
    • Blood-flow imaging with MR: Spin-phase phenomena
    • G. K. von Schulthess, C. B. Higgins, Blood-flow imaging with MR: spin-phase phenomena. Radiology 157, 687-695 (1985).
    • (1985) Radiology , vol.157 , pp. 687-695
    • Von Schulthess, G.K.1    Higgins, C.B.2
  • 27
    • 0031105449 scopus 로고    scopus 로고
    • Fluid mechanics of arterial stenosis: Relationship to the development of mural thrombus
    • D. Bluestein, L. Niu, R. T. Schoephoerster, M. K. Dewanjee, Fluid mechanics of arterial stenosis: relationship to the development of mural thrombus, Ann. Biomed. Eng. 25, 344-356 (1997).
    • (1997) Ann. Biomed. Eng. , vol.25 , pp. 344-356
    • Bluestein, D.1    Niu, L.2    Schoephoerster, R.T.3    Dewanjee, M.K.4
  • 29
    • 0015396531 scopus 로고
    • Shear-layer regimens and wave instabilities and reattachment lengths downstream of an abrupt circular channel expansion
    • L. H. Back, E. J. Roschke, Shear-layer regimens and wave instabilities and reattachment lengths downstream of an abrupt circular channel expansion, ASME J. Appl. Mech. 39, 677-681 (1972).
    • (1972) ASME J. Appl. Mech. , vol.39 , pp. 677-681
    • Back, L.H.1    Roschke, E.J.2
  • 30
    • 0000296172 scopus 로고
    • Self-sustained oscillations of a confined jet: A case study for the non-linear delayed saturation model
    • E. Villermaux, E. J. Hopfinger, Self-sustained oscillations of a confined jet: a case study for the non-linear delayed saturation model, Physica D 72, 230-243 (1994).
    • (1994) Physica D , vol.72 , pp. 230-243
    • Villermaux, E.1    Hopfinger, E.J.2
  • 33
    • 0028144620 scopus 로고
    • Radioactive microsphere validation of a volume localized continuous saturation perfusion measurement
    • E. G. Walsh, K. Minematsu, J. Leppo, S. C. Moore, Radioactive microsphere validation of a volume localized continuous saturation perfusion measurement, Magn. Reson. Med. 31, 147-153 (1994).
    • (1994) Magn. Reson. Med. , vol.31 , pp. 147-153
    • Walsh, E.G.1    Minematsu, K.2    Leppo, J.3    Moore, S.C.4
  • 35
    • 0002471498 scopus 로고
    • A new method for suppressing baseline distortions in FT NMR
    • A. Heuer, U. Haeberlen, A new method for suppressing baseline distortions in FT NMR, J. Magn. Reson. 85, 79-94 (1989).
    • (1989) J. Magn. Reson. , vol.85 , pp. 79-94
    • Heuer, A.1    Haeberlen, U.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.