메뉴 건너뛰기




Volumn 40, Issue 1, 1998, Pages 20-27

An assessment of pulse-echo and hydrophone methods for characterising ultrasonic NDT transducers

Author keywords

[No Author keywords available]

Indexed keywords

ACOUSTIC DISTORTION; ACOUSTIC FIELD MEASUREMENT; BANDWIDTH; FREQUENCY RESPONSE; HYDROPHONES; NONDESTRUCTIVE EXAMINATION; NUMERICAL ANALYSIS;

EID: 0031674704     PISSN: 13542575     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (7)

References (12)
  • 4
    • 0018330821 scopus 로고
    • Theoretical and experimental methods to evaluate ultrasonic transducers for inspection and diagnostic applications
    • January
    • Papadakis E P. 'Theoretical and experimental methods to evaluate ultrasonic transducers for inspection and diagnostic applications', IEEE Transactions on Sonics and Ultrasonics, Vol SU-26, No 1 pp 14-27, January 1979.
    • (1979) IEEE Transactions on Sonics and Ultrasonics , vol.SU-26 , Issue.1 , pp. 14-27
    • Papadakis, E.P.1
  • 5
    • 0029230663 scopus 로고
    • Near and far field experimental evaluations of ultrasonic transducers
    • Bin Hu and Houghton, J R. 'Near and far field experimental evaluations of ultrasonic transducers', NDE, Vol 13 pp 17-24 1995.
    • (1995) NDE , vol.13 , pp. 17-24
    • Hu, B.1    Houghton, J.R.2
  • 6
    • 15844410807 scopus 로고    scopus 로고
    • Standardisation of procedures for ultrasonic inspection of polymer matrix composites: Transducer characterisation and materials evaluation
    • November
    • Zeqiri B and Hodnett M. 'Standardisation of procedures for ultrasonic inspection of polymer matrix composites: transducer characterisation and materials evaluation', NPL Report CMAM 9, November 1997.
    • (1997) NPL Report CMAM , vol.9
    • Zeqiri, B.1    Hodnett, M.2
  • 7
    • 0031646459 scopus 로고    scopus 로고
    • Overview of DTI-funded Programme on standardised procedures for ultrasonic inspection of polymer matrix composites
    • Broughton WR, Sims GD and Lodeiro MJ. 'Overview of DTI-funded Programme on standardised procedures for ultrasonic inspection of polymer matrix composites'. INSIGHT, Vol 40, No. l, pp 8-11, 1998.
    • (1998) INSIGHT , vol.40 , Issue.50 , pp. 8-11
    • Broughton, W.R.1    Sims, G.D.2    Lodeiro, M.J.3
  • 8
    • 0020799628 scopus 로고
    • PVDF membrane hydrophone performance properties and their relevance to the measurement of the acoustic output of medical ultrasonic equipment
    • Preston R C, Bacon D R, Livett A J and Rajendran K. 'PVDF membrane hydrophone performance properties and their relevance to the measurement of the acoustic output of medical ultrasonic equipment', J Phys E: Sci Instrum, Vol 16 pp 786-796, 1983.
    • (1983) J Phys E: Sci Instrum , vol.16 , pp. 786-796
    • Preston, R.C.1    Bacon, D.R.2    Livett, A.J.3    Rajendran, K.4
  • 9
    • 0031701058 scopus 로고    scopus 로고
    • Nonlinear propagation in water and its effect on ultrasonic C-scanning
    • Smith R A, Zeqiri B, Jones L D, and Hodnett M. 'Nonlinear propagation in water and its effect on ultrasonic C-scanning', INSIGHT, Vol 40, No. 1, pp 12-19, 1998.
    • (1998) INSIGHT , vol.40 , Issue.1 , pp. 12-19
    • Smith, R.A.1    Zeqiri, B.2    Jones, L.D.3    Hodnett, M.4
  • 10
    • 0031048088 scopus 로고    scopus 로고
    • An experimental study of the reflection from spherical and flat-ended cylindrical targets for Fetal Doppler performance assessment
    • Preston RC and Bond AD. 'An experimental study of the reflection from spherical and flat-ended cylindrical targets for Fetal Doppler performance assessment', Ultrasound in Med and Biol, Vol 23, pp 117-128, 1997.
    • (1997) Ultrasound in Med and Biol , vol.23 , pp. 117-128
    • Preston, R.C.1    Bond, A.D.2
  • 11
    • 0023981195 scopus 로고
    • Calibration of medical ultrasonic equipment - Procedures and accuracy assessment
    • Preston R C, Bacon D R and Smith R A. 'Calibration of medical ultrasonic equipment - procedures and accuracy assessment', IEEE Trans Ultrason Ferroelec Freq Contr, Vol 35, pp 110-122 1988.
    • (1988) IEEE Trans Ultrason Ferroelec Freq Contr , vol.35 , pp. 110-122
    • Preston, R.C.1    Bacon, D.R.2    Smith, R.A.3
  • 12
    • 0004635885 scopus 로고
    • Ultrasonic defect sizing in carbon-fibre composites - An initial study
    • Smith R A. 'Ultrasonic defect sizing in carbon-fibre composites - an initial study', INSIGHT, Vol 36, pp 595-605, 1994.
    • (1994) INSIGHT , vol.36 , pp. 595-605
    • Smith, R.A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.