메뉴 건너뛰기




Volumn 40, Issue 1, 1998, Pages 8-11

Overview of DTI-funded programme on 'Standardised procedures for ultrasonic inspection of polymer matrix composites'

Author keywords

[No Author keywords available]

Indexed keywords

DEFECTS; NONMETALLIC MATRIX COMPOSITES; ULTRASONIC APPLICATIONS;

EID: 0031646459     PISSN: 13542575     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (8)

References (13)
  • 3
    • 15844388302 scopus 로고
    • Standard guide for evaluating characteristics of ultrasonic search units
    • ASTM E 1065-92, Volume 03.03 Nondestructive Testing
    • ASTM E 1065-92, 'Standard Guide for Evaluating Characteristics of Ultrasonic search Units', Annual Book of ASTM Standards, Volume 03.03 Nondestructive Testing, pp 448-466, 1994.
    • (1994) Annual Book of ASTM Standards , pp. 448-466
  • 4
    • 0004635885 scopus 로고
    • Ultrasonic defect sizing in carbon-fibre composites - An Initial study
    • August
    • Smith, R.A., 'Ultrasonic Defect Sizing in Carbon-Fibre Composites - An initial Study', INSIGHT, Vol 36, No 8, pp 595-605, August 1994.
    • (1994) INSIGHT , vol.36 , Issue.8 , pp. 595-605
    • Smith, R.A.1
  • 5
    • 0031699666 scopus 로고    scopus 로고
    • Diffraction and shadowing errors in -6 dB defect sizing of delaminations in composites
    • January
    • Smith R A, Jones L D, Willsher S J and Marriott A B, 'Diffraction and shadowing errors in -6 dB defect sizing of delaminations in composites', INSIGHT Vol 40 No 1, pp 44-49, January 1998.
    • (1998) INSIGHT , vol.40 , Issue.1 , pp. 44-49
    • Smith, R.A.1    Jones, L.D.2    Willsher, S.J.3    Marriott, A.B.4
  • 6
    • 0031647391 scopus 로고    scopus 로고
    • Ultrasonic C-scan standardisation for fibre-reinforced polymer composites - Minimising the uncertainties in attenuation measurements
    • January
    • Smith R A, Jones L D, Zeqiri B and Hodnett M, 'Ultrasonic C-scan standardisation for fibre-reinforced polymer composites - minimising the uncertainties in attenuation measurements', INSIGHT Vol 40 No 1, pp 34-43, January 1998.
    • (1998) INSIGHT , vol.40 , Issue.1 , pp. 34-43
    • Smith, R.A.1    Jones, L.D.2    Zeqiri, B.3    Hodnett, M.4
  • 7
    • 0031701058 scopus 로고    scopus 로고
    • Nonlinear propagation in water and its effect on ultrasonic C-scanning
    • January
    • Smith R A, Zeqiri B, Jones L D and Hodnett M, 'Nonlinear propagation in water and its effect on ultrasonic C-scanning', INSIGHT Vol 40 No 1, pp 12-19, January 1998.
    • (1998) INSIGHT , vol.40 , Issue.1 , pp. 12-19
    • Smith, R.A.1    Zeqiri, B.2    Jones, L.D.3    Hodnett, M.4
  • 8
    • 0031674704 scopus 로고    scopus 로고
    • An assessment of pulse-echo and hydrophone methods for characterising ultrasonic NDT transducers
    • January
    • Zeqiri B, Hodnett M, Smith RA and Scudder LP, 'An assessment of pulse-echo and hydrophone methods for characterising ultrasonic NDT transducers', INSIGHT Vol 40 No 1, pp 20-27, January 1998.
    • (1998) INSIGHT , vol.40 , Issue.1 , pp. 20-27
    • Zeqiri, B.1    Hodnett, M.2    Smith, R.A.3    Scudder, L.P.4
  • 9
    • 0031673134 scopus 로고    scopus 로고
    • A systematic investigation of the effect of collimators on the characteristics of NDT transducers
    • January
    • Zeqiri B and Hodnett M, 'A systematic investigation of the effect of collimators on the characteristics of NDT transducers, INSIGHT Vol 40 No 1, pp 28-33, January 1998.
    • (1998) INSIGHT , vol.40 , Issue.1 , pp. 28-33
    • Zeqiri, B.1    Hodnett, M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.