메뉴 건너뛰기




Volumn 44, Issue 6, 1997, Pages 1286-1296

Three-dimensional tissue motion and its effect on image noise in elastography

Author keywords

[No Author keywords available]

Indexed keywords

CORRELATION METHODS; IMAGE COMPRESSION; IMAGE QUALITY; MEDICAL IMAGING; SIGNAL TO NOISE RATIO; SPURIOUS SIGNAL NOISE; TISSUE; ULTRASONIC SCATTERING;

EID: 0031274258     PISSN: 08853010     EISSN: None     Source Type: Journal    
DOI: 10.1109/58.656632     Document Type: Article
Times cited : (64)

References (34)
  • 2
    • 0025806883 scopus 로고    scopus 로고
    • Elastography: A method for imaging tissue elasticity in biological tissues
    • vol. 13, pp. 111-134, 1991.
    • J. Ophir, I. Céspedes, H. Ponnekanti, Y. Yazdi, and X. Li, "Elastography: a method for imaging tissue elasticity in biological tissues," Ultrason, Imaging, vol. 13, pp. 111-134, 1991.
    • Ultrason, Imaging
    • Ophir, J.1    Céspedes, I.2    Ponnekanti, H.3    Yazdi, Y.4    Li, X.5
  • 3
    • 0031030125 scopus 로고    scopus 로고
    • Elastography of breast lesions: Initial clinical results
    • vol. 202, pp. 79-86, 1997.
    • B. S. Garra, I. Céspedes, J. Ophir, and S. Spratt, "Elastography of breast lesions: initial clinical results," Radiology, vol. 202, pp. 79-86, 1997.
    • Radiology
    • Garra, B.S.1    Céspedes, I.2    Ophir, J.3    Spratt, S.4
  • 4
    • 0029002768 scopus 로고    scopus 로고
    • Fundamental mechanical imitations on the visualization of elasticity contrast in elastography
    • vol. 21, pp. 533-543, 1995.
    • H. Ponnekanti, J. Ophir, J. Huang, and I. Cespedes, "Fundamental mechanical imitations on the visualization of elasticity contrast in elastography," Ultrason. Med. Biol., vol. 21, pp. 533-543, 1995.
    • Ultrason. Med. Biol.
    • Ponnekanti, H.1    Ophir, J.2    Huang, J.3    Cespedes, I.4
  • 5
    • 0028559733 scopus 로고    scopus 로고
    • Lesion detection in elastography versus echography: A quantitative analysis
    • vol. 20, pp. 877-891, 1994.
    • N. Belaid, I. Céspedes, J. Thijssen, and J. Ophir, "Lesion detection in elastography versus echography: a quantitative analysis," Ultrason. Med. Biol., vol. 20, pp. 877-891, 1994.
    • Ultrason. Med. Biol.
    • Belaid, N.1    Céspedes, I.2    Thijssen, J.3    Ophir, J.4
  • 6
    • 0030173129 scopus 로고    scopus 로고
    • Tissue elasticity reconstruction using linear perturbation method
    • vol. 15, pp. 299-313, 1996.
    • F. Kallel and M. Bertrand, "Tissue elasticity reconstruction using linear perturbation method," IEEE Trans. Med. Imag., vol. 15, pp. 299-313, 1996.
    • IEEE Trans. Med. Imag.
    • Kallel, F.1    Bertrand, M.2
  • 8
    • 0029937329 scopus 로고    scopus 로고
    • Fundamental limitations on the contrast-transfer efficiency in elastography: An analytic study
    • vol. 22, pp. 463-470, 1996.
    • F. Kallel, M. Bertrand, and J. Ophir, "Fundamental limitations on the contrast-transfer efficiency in elastography: an analytic study," Ultrason. Med. Biol., vol. 22, pp. 463-470, 1996.
    • Ultrason. Med. Biol.
    • Kallel, F.1    Bertrand, M.2    Ophir, J.3
  • 10
    • 0030734228 scopus 로고    scopus 로고
    • A theoretical framework for performance characterization of elastography: The strain filter
    • vol. 44, no. 1, pp. 164-174, 1997.
    • T. Varghese and J. Ophir, "A theoretical framework for performance characterization of elastography: the strain filter," IEEE Trans. Ultrason., Ferroelect., Freq. Contr., vol. 44, no. 1, pp. 164-174, 1997.
    • IEEE Trans. Ultrason., Ferroelect., Freq. Contr.
    • Varghese, T.1    Ophir, J.2
  • 11
    • 0030736520 scopus 로고    scopus 로고
    • Enhancement of echo-signal correlation in elastography using temporal stretching
    • vol. 44, no. 1, pp. 175-180, 1997.
    • T. Varghese and J. Ophir, "Enhancement of echo-signal correlation in elastography using temporal stretching," IEEE Trans. Ultrason., Ferroelect., Freq. Contr., vol. 44, no. 1, pp. 175-180, 1997.
    • IEEE Trans. Ultrason., Ferroelect., Freq. Contr.
    • Varghese, T.1    Ophir, J.2
  • 14
    • 0031042473 scopus 로고    scopus 로고
    • Error analysis in acoustic elastography: I. Displacement estimation
    • vol. 101, pp 1139-1146, 1997.
    • M. Bilgen and M. F. Insana, "Error analysis in acoustic elastography: I. Displacement estimation," J. Acoust. Soc. Am., vol. 101, pp 1139-1146, 1997.
    • J. Acoust. Soc. Am.
    • Bilgen, M.1    Insana, M.F.2
  • 15
    • 0031055370 scopus 로고    scopus 로고
    • Error analysis in acoustic elastography: II. Strain estimation and SNR analysis
    • vol. 101, pp 1147-1154, 1997.
    • M. Bilgen and M. F. Insana, "Error analysis in acoustic elastography: II. Strain estimation and SNR analysis," J. Acoust. Soc. Am., vol. 101, pp 1147-1154, 1997.
    • J. Acoust. Soc. Am.
    • Bilgen, M.1    Insana, M.F.2
  • 16
    • 0031056017 scopus 로고    scopus 로고
    • Reduction of signal decorrelation from mechanical compression of tissues by temporal stretching
    • vol. 23, pp. 95-105, 1997.
    • S. K. Alam and J. Ophir, "Reduction of signal decorrelation from mechanical compression of tissues by temporal stretching," Ultrason. Med. Biol., vol. 23, pp. 95-105, 1997.
    • Ultrason. Med. Biol.
    • Alam, S.K.1    Ophir, J.2
  • 19
    • 0029239565 scopus 로고    scopus 로고
    • Estimation of shear modulus distribution in soft tissue from strain distribution
    • vol. 42, pp. 193-202, 1995.
    • C. Sumi, A. Suzuki, and K. Nakayama, "Estimation of shear modulus distribution in soft tissue from strain distribution," IEEE Trans. Biomed. Eng., vol. 42, pp. 193-202, 1995.
    • IEEE Trans. Biomed. Eng.
    • Sumi, C.1    Suzuki, A.2    Nakayama, K.3
  • 21
    • 0021515775 scopus 로고    scopus 로고
    • Fundamental limitations in passive time delay estimation - Part I: Narrow-band systems
    • vol. ASSP-31, pp. 472-485, 1983.
    • E. Weinstein and A. Weiss, "Fundamental limitations in passive time delay estimation - Part I: Narrow-band systems," IEEE Trans. Acoust., Speech, Signal Processing, vol. ASSP-31, pp. 472-485, 1983.
    • IEEE Trans. Acoust., Speech, Signal Processing
    • Weinstein, E.1    Weiss, A.2
  • 22
    • 0021515775 scopus 로고    scopus 로고
    • Fundamental limitations in passive time delay estimation - Part II: Wide-band systems
    • vol. ASSP-31, pp. 1064-1078, 1984.
    • E. Weinstein and A. Weiss, "Fundamental limitations in passive time delay estimation - Part II: Wide-band systems," IEEE Trans. Acoust., Speech, Signal Processing, vol. ASSP-31, pp. 1064-1078, 1984.
    • IEEE Trans. Acoust., Speech, Signal Processing
    • Weinstein, E.1    Weiss, A.2
  • 23
    • 0022717660 scopus 로고    scopus 로고
    • Speckle pattern correlation with lateral aperture translation: Experimental results and implications for spatial compounding
    • vol. UFFC-33, pp. 257-264, 1986.
    • G. E. Trahey, S. W. Smith, and O. T. von Ramm, "Speckle pattern correlation with lateral aperture translation: experimental results and implications for spatial compounding," IEEE Trans. Ultrason., Ferroelect., Freq. Contr., vol. UFFC-33, pp. 257-264, 1986.
    • IEEE Trans. Ultrason., Ferroelect., Freq. Contr.
    • Trahey, G.E.1    Smith, S.W.2    Von Ramm, O.T.3
  • 24
    • 0029324838 scopus 로고    scopus 로고
    • Ultrasonic texture motion analysis: Theory and simulation
    • vol. 14, pp. 203-300, 1995.
    • J. Meunier and M. Bertrand, "Ultrasonic texture motion analysis: theory and simulation," IEEE Trans. Med. Imag., vol. 14, pp. 203-300, 1995.
    • IEEE Trans. Med. Imag.
    • Meunier, J.1    Bertrand, M.2
  • 25
    • 0030785945 scopus 로고    scopus 로고
    • The combined effect of signal decorrelation and random noise on time delay estimation
    • vol. 44, no. 1, pp. 220-225, 1997.
    • I. Céspedes, J. Ophir, and S. K. Alam, "The combined effect of signal decorrelation and random noise on time delay estimation," IEEE Trans. Ultrason., Ferroelect., Freq. Contr., vol. 44, no. 1, pp. 220-225, 1997.
    • IEEE Trans. Ultrason., Ferroelect., Freq. Contr.
    • Céspedes, I.1    Ophir, J.2    Alam, S.K.3
  • 26
    • 0025040047 scopus 로고    scopus 로고
    • Tissue response to mechanical vibrations for sonoelasticity imaging
    • vol. 16, pp. 241-246, 1990.
    • K. J. Parker, S. R. Huang, R. A. Musulin, and R. M. Lerner, "Tissue response to mechanical vibrations for sonoelasticity imaging," Ultrason. Med. Biol., vol. 16, pp. 241-246, 1990.
    • Ultrason. Med. Biol.
    • Parker, K.J.1    Huang, S.R.2    Musulin, R.A.3    Lerner, R.M.4
  • 27
    • 0000646745 scopus 로고    scopus 로고
    • Shear acoustic properties of soft biological tissues in medical diagnostics
    • vol. 93, part 2, p. 2329, 1993.
    • A. P. Sarvazyan, "Shear acoustic properties of soft biological tissues in medical diagnostics," J. Acoust. Soc. Amer. Proc. 125th Meeting, vol. 93, part 2, p. 2329, 1993.
    • J. Acoust. Soc. Amer. Proc. 125th Meeting
    • Sarvazyan, A.P.1
  • 28
    • 0017514650 scopus 로고    scopus 로고
    • The effective directivity characteristic of a pulsed ultrasound transducer and its measurement by semi-automatic means
    • vol. 15, pp. 169-174, 1977.
    • J. C. Bamber and J. V. Phelps, "The effective directivity characteristic of a pulsed ultrasound transducer and its measurement by semi-automatic means," Ultrasonics, vol. 15, pp. 169-174, 1977.
    • Ultrasonics
    • Bamber, J.C.1    Phelps, J.V.2
  • 30
    • 0023941858 scopus 로고    scopus 로고
    • Properties of acoustical speckle in the presence of phase aberration. Part II: Correlation lengths
    • vol. 10, pp. 29-51, 1988.
    • S. W. Smith, E. G. Trahey, S. M. Hubbard, and F. Wagner, "Properties of acoustical speckle in the presence of phase aberration. Part II: correlation lengths," Ultrason. Imaging, vol. 10, pp. 29-51, 1988.
    • Ultrason. Imaging
    • Smith, S.W.1    Trahey, E.G.2    Hubbard, S.M.3    Wagner, F.4
  • 34
    • 2642623603 scopus 로고    scopus 로고
    • Developing phantoms for elastography
    • vol. 18, Abstract, p. 70, 1996.
    • T. Hall, M. F. Insana, and M. Bilgen, "Developing phantoms for elastography," Ultrasonic Imaging, vol. 18, Abstract, p. 70, 1996.
    • Ultrasonic Imaging
    • Hall, T.1    Insana, M.F.2    Bilgen, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.