메뉴 건너뛰기




Volumn 12, Issue 4, 1997, Pages 486-494

A 1-Year Follow-up of Implants of Differing Surface Roughness Placed in Rabbit Bone

Author keywords

Bone fixation; Implants; Surface roughness

Indexed keywords

ALUMINUM OXIDE; COLORING AGENT; DIAGNOSTIC AGENT; TITANIUM; TOLONIUM CHLORIDE;

EID: 0031178275     PISSN: 08822786     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (244)

References (30)
  • 1
    • 0029268053 scopus 로고
    • A histomorphometric and removal torque study of screw-shaped titanium implants with three different surface topographies
    • Wennerberg A, Albrektsson T, Andersson B, Krol JJ. A histomorphometric and removal torque study of screw-shaped titanium implants with three different surface topographies. Clin Oral Impl Res 1995;6:24-30.
    • (1995) Clin Oral Impl Res , vol.6 , pp. 24-30
    • Wennerberg, A.1    Albrektsson, T.2    Andersson, B.3    Krol, J.J.4
  • 2
    • 0029002976 scopus 로고
    • An animal study of c.p. titanium screws with different surface topographies
    • Wennerberg A, Albrektsson T, Andersson B. An animal study of c.p. titanium screws with different surface topographies. J Mater Sci Mater Med 1995;6:302-309.
    • (1995) J Mater Sci Mater Med , vol.6 , pp. 302-309
    • Wennerberg, A.1    Albrektsson, T.2    Andersson, B.3
  • 3
    • 0029655580 scopus 로고    scopus 로고
    • An experimental study of turned and grit blasted screw-shaped implants with special emphasis on effects of blasting materials and surface topography
    • Wennerberg A, Albrektsson T, Johansson C, Andersson B. An experimental study of turned and grit blasted screw-shaped implants with special emphasis on effects of blasting materials and surface topography. Biomaterials 1996;17:15-22.
    • (1996) Biomaterials , vol.17 , pp. 15-22
    • Wennerberg, A.1    Albrektsson, T.2    Johansson, C.3    Andersson, B.4
  • 4
    • 0029681619 scopus 로고    scopus 로고
    • Bone tissue response to commercially pure titanium implants blasted with fine and coarse particles of aluminum oxide
    • Wennerberg A, Albrektsson T, Andersson B. Bone tissue response to commercially pure titanium implants blasted with fine and coarse particles of aluminum oxide. Int J Oral Maxillofac Implants 1996;11:38-45.
    • (1996) Int J Oral Maxillofac Implants , vol.11 , pp. 38-45
    • Wennerberg, A.1    Albrektsson, T.2    Andersson, B.3
  • 8
    • 0021120213 scopus 로고
    • Metal ion release from titanium-based prosthetic segmental replacements of long bones in baboons: A long term study
    • Woodman JL, Jacobs JJ, Galante JO, Urban R. Metal ion release from titanium-based prosthetic segmental replacements of long bones in baboons: A long term study. J Orthop Res 1984;1:421-430.
    • (1984) J Orthop Res , vol.1 , pp. 421-430
    • Woodman, J.L.1    Jacobs, J.J.2    Galante, J.O.3    Urban, R.4
  • 10
    • 0041011817 scopus 로고
    • The release of titanium into human bone from a titanium implant coated with plasmasprayed titanium
    • Heimke G, Soltész U, Lee AJC (eds) Amsterdam: Elsevier Science
    • Osborn JF, Willich P, Meenen N. The release of titanium into human bone from a titanium implant coated with plasmasprayed titanium. In: Heimke G, Soltész U, Lee AJC (eds). Clinical Implant Materials. Advances in Biomaterials. Amsterdam: Elsevier Science, 1990;9:75-80.
    • (1990) Clinical Implant Materials. Advances in Biomaterials , vol.9 , pp. 75-80
    • Osborn, J.F.1    Willich, P.2    Meenen, N.3
  • 11
    • 0021412486 scopus 로고
    • Electron microprobe analysis of metal ion transport in cortical bone
    • Woodman J, Shinn W, Urban R, Galante J. Electron microprobe analysis of metal ion transport in cortical bone. J Biomed Mater Res 1984;18:463-466.
    • (1984) J Biomed Mater Res , vol.18 , pp. 463-466
    • Woodman, J.1    Shinn, W.2    Urban, R.3    Galante, J.4
  • 13
    • 0024145064 scopus 로고
    • Titanium and calcium phosphate ceramic dental implants, surfaces, coatings and interfaces
    • Ducheyne P. Titanium and calcium phosphate ceramic dental implants, surfaces, coatings and interfaces. J Oral Implantol 1988;14:325-440.
    • (1988) J Oral Implantol , vol.14 , pp. 325-440
    • Ducheyne, P.1
  • 14
    • 0024655938 scopus 로고
    • Inhibition of apatite formation by titanium and vanadium ions
    • Blumenthal NC, Cosma V. Inhibition of apatite formation by titanium and vanadium ions. J Biomed Mater Res Appl Biomater 1989;23:13-22.
    • (1989) J Biomed Mater Res Appl Biomater , vol.23 , pp. 13-22
    • Blumenthal, N.C.1    Cosma, V.2
  • 16
    • 0026314753 scopus 로고
    • Release of metal ions from dental implant materials in vivo: Determination of Al, Co, Cr, Mo, Ni, V, and Ti in organ tissue
    • Lugowski SJ, Smith C, McHugh AD, Van Loon JC. Release of metal ions from dental implant materials in vivo: Determination of Al, Co, Cr, Mo, Ni, V, and Ti in organ tissue. J Biomed Mater Res 1992;25:1443-1458.
    • (1992) J Biomed Mater Res , vol.25 , pp. 1443-1458
    • Lugowski, S.J.1    Smith, C.2    McHugh, A.D.3    Van Loon, J.C.4
  • 17
    • 0026739199 scopus 로고
    • An optical 3D method for topographical description of surgical implants
    • Wennerberg A, Albrektsson T, Ulrich H, Krol J. An optical 3D method for topographical description of surgical implants. J Biomed Eng 1992;14:412-418.
    • (1992) J Biomed Eng , vol.14 , pp. 412-418
    • Wennerberg, A.1    Albrektsson, T.2    Ulrich, H.3    Krol, J.4
  • 18
    • 0027874357 scopus 로고
    • Design and surface characteristics of 13 commercially available oral implant systems
    • Wennerberg A, Albrektsson T, Andersson B. Design and surface characteristics of 13 commercially available oral implant systems. Int J Oral Maxillofac Implants 1993;8:622-633.
    • (1993) Int J Oral Maxillofac Implants , vol.8 , pp. 622-633
    • Wennerberg, A.1    Albrektsson, T.2    Andersson, B.3
  • 21
    • 0001047699 scopus 로고
    • Die trenn-dünnschlif-technik zur herstellung histologischer präparate von nicht schneidbaren geweben und materialen
    • Donath K. Die trenn-dünnschlif-technik zur herstellung histologischer präparate von nicht schneidbaren geweben und materialen. Präparator 1988;34:197-206.
    • (1988) Präparator , vol.34 , pp. 197-206
    • Donath, K.1
  • 26
    • 0025485123 scopus 로고
    • Titanium-coated micromachined grooves of different dimensions affect epithelial and connective-tissue cells differently in vivo
    • Chehroudi B, Could TRL, Brunette DM. Titanium-coated micromachined grooves of different dimensions affect epithelial and connective-tissue cells differently in vivo. J Biomed Mater Res 1990;24:1203-1219.
    • (1990) J Biomed Mater Res , vol.24 , pp. 1203-1219
    • Chehroudi, B.1    Could, T.R.L.2    Brunette, D.M.3
  • 27
    • 0023302919 scopus 로고
    • Integration of screw implants in the rabbit: A 1-year follow-up of removal torque of titanium implants
    • Johansson C, Albrektsson T. Integration of screw implants in the rabbit: A 1-year follow-up of removal torque of titanium implants. Int J Oral Maxillofacial Implants 1987;2:69-72.
    • (1987) Int J Oral Maxillofacial Implants , vol.2 , pp. 69-72
    • Johansson, C.1    Albrektsson, T.2
  • 28
    • 0022991734 scopus 로고
    • Biological fixation of various titanium and carbon implants in cancellous bone: Biomechanical and histomorphological evaluation
    • Christel P, Meunier A, Lee AJC (eds) Amsterdam: Elsevier Science
    • Kiefer H, Claes L, Burri C, Kuglmeier K. Biological fixation of various titanium and carbon implants in cancellous bone: Biomechanical and histomorphological evaluation. In: Christel P, Meunier A, Lee AJC (eds). Biological and Biomechanical Performance of Biomaterials. Amsterdam: Elsevier Science, 1986:471-476.
    • (1986) Biological and Biomechanical Performance of Biomaterials , pp. 471-476
    • Kiefer, H.1    Claes, L.2    Burri, C.3    Kuglmeier, K.4
  • 29
    • 0031244133 scopus 로고    scopus 로고
    • Short- and long-term animal studies with a plasma-sprayed calcium phosphate-coated bone implant
    • in press
    • Gottlander M, Johansson CB, Albrektsson T. Short- and long-term animal studies with a plasma-sprayed calcium phosphate-coated bone implant. Clin Oral Impl Res 1997 (in press).
    • (1997) Clin Oral Impl Res
    • Gottlander, M.1    Johansson, C.B.2    Albrektsson, T.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.