메뉴 건너뛰기




Volumn 30, Issue 5, 1997, Pages 531-536

Finite element modeling and experimental verification of lower extremity shape change under load

Author keywords

Anthropometry; Finite element modeling; Lower limb prosthetics; Material properties determination; Spiral computed tomography

Indexed keywords

ANTHROPOMETRY; BIOMECHANICS; COMPUTERIZED TOMOGRAPHY; ELASTICITY; ESTIMATION; FINITE ELEMENT METHOD; MATHEMATICAL MODELS; TISSUE;

EID: 0031148570     PISSN: 00219290     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0021-9290(96)00179-0     Document Type: Article
Times cited : (24)

References (34)
  • 1
    • 0025448211 scopus 로고
    • The p and h-p versions of the finite element method, an overview
    • Babuska, I. and Suri, M. (1990) The p and h-p versions of the finite element method, an overview. Comput. Methods Appl. Mech. Engng 80, 5-26.
    • (1990) Comput. Methods Appl. Mech. Engng , vol.80 , pp. 5-26
    • Babuska, I.1    Suri, M.2
  • 2
    • 0001759083 scopus 로고
    • The p-version of the finite element method SIAM
    • Babuska, I., Szabo, B. A. and Katz, I. N. (1981) The p-version of the finite element method SIAM. J. Numer. Anal. 18, 515-545.
    • (1981) J. Numer. Anal. , vol.18 , pp. 515-545
    • Babuska, I.1    Szabo, B.A.2    Katz, I.N.3
  • 3
    • 0022283268 scopus 로고
    • Three-D femoral stress analysis using CT scans and p-version FEM
    • Basu, P. K., Beall, A. G., Simmons, D. and Vannier, M. W. (1986) Three-D femoral stress analysis using CT scans and p-version FEM. Biomat. Med. Dev. Artif. Org. 13(3-4), 163-186.
    • (1986) Biomat. Med. Dev. Artif. Org. , vol.13 , Issue.3-4 , pp. 163-186
    • Basu, P.K.1    Beall, A.G.2    Simmons, D.3    Vannier, M.W.4
  • 4
    • 0030005557 scopus 로고    scopus 로고
    • Precision of surface measurements for below knee residua. Archives of physical medicine and rehabilitation research
    • Commean, P. K., Smith, K. E., Cheverud, J. M. and Vannier, M. W. (1996) Precision of surface measurements for below knee residua. Archives of physical medicine and rehabilitation research. Arch. Phys. Med. Rehabil. 77, 477-486.
    • (1996) Arch. Phys. Med. Rehabil. , vol.77 , pp. 477-486
    • Commean, P.K.1    Smith, K.E.2    Cheverud, J.M.3    Vannier, M.W.4
  • 6
    • 0025221610 scopus 로고
    • Computed tomography scanning with simultaneous patient translation
    • Crawford, C. R. and King, K. F. (1990) Computed tomography scanning with simultaneous patient translation. Med. Phys. 17, 967-982.
    • (1990) Med. Phys. , vol.17 , pp. 967-982
    • Crawford, C.R.1    King, K.F.2
  • 8
    • 0010269865 scopus 로고
    • Estimation of regional myocardial stress: p-version finite element analysis using an MRI-based solid mathematical model
    • Creswell, L. L., Pirolo, J. S., Szabo, B. A., Myers, K. W., Bresina, S. J., Perman, W. H., Vannier, M. W. and Pasque, M. K. (1992) Estimation of regional myocardial stress: p-version finite element analysis using an MRI-based solid mathematical model. Automedica 14, 319-334.
    • (1992) Automedica , vol.14 , pp. 319-334
    • Creswell, L.L.1    Pirolo, J.S.2    Szabo, B.A.3    Myers, K.W.4    Bresina, S.J.5    Perman, W.H.6    Vannier, M.W.7    Pasque, M.K.8
  • 9
    • 0003317919 scopus 로고
    • Computer designed prosthetic socket from analysis of computed tomography data
    • Faulkner, V. W. and Walsh, N. E. (1989) Computer designed prosthetic socket from analysis of computed tomography data. J. Prosth. Orthot. 1(3), 154-164.
    • (1989) J. Prosth. Orthot. , vol.1 , Issue.3 , pp. 154-164
    • Faulkner, V.W.1    Walsh, N.E.2
  • 10
    • 0026048199 scopus 로고
    • Physical performance characteristics of spiral CT scanning
    • Kalender, W. A. and Polacin, A. (1991) Physical performance characteristics of spiral CT scanning. Med. Phys. 18, 910-915.
    • (1991) Med. Phys. , vol.18 , pp. 910-915
    • Kalender, W.A.1    Polacin, A.2
  • 11
    • 0028298099 scopus 로고
    • A comparison of conventional and spiral CT: An experimental study on the detection of spherical lesions
    • Kalender, W. A., Polacin, A. and Suss, C. (1994) A comparison of conventional and spiral CT: an experimental study on the detection of spherical lesions. J. Comput. Assist. Tomogr. 18(2), 167-176.
    • (1994) J. Comput. Assist. Tomogr. , vol.18 , Issue.2 , pp. 167-176
    • Kalender, W.A.1    Polacin, A.2    Suss, C.3
  • 12
    • 0025351273 scopus 로고
    • Spiral volumetric CT with single-breath-hold technique, continuous transport, and continuous scanner rotation
    • Kalender, W. A., Seissler, W., Klotz, E. and Vock, P. (1990) Spiral volumetric CT with single-breath-hold technique, continuous transport, and continuous scanner rotation. Radiology 176, 181-183.
    • (1990) Radiology , vol.176 , pp. 181-183
    • Kalender, W.A.1    Seissler, W.2    Klotz, E.3    Vock, P.4
  • 13
    • 0027809168 scopus 로고
    • An inverse material identification algorithm for determining in vivo myocardial material properties. Part 2: Medical informatics, ethics, cardiology, instrumentation
    • Moulton, M. J., Creswell, L. L., Wyers, S. G., Actis, R. L., Szabo, B. A., Vannier, M. W. and Pasque, M. K. (1993) An inverse material identification algorithm for determining in vivo myocardial material properties. Part 2: medical informatics, ethics, cardiology, instrumentation. Proc. Annual Int. Conf. IEEE EMBS, Vol. 15, 901-902.
    • (1993) Proc. Annual Int. Conf. IEEE EMBS , vol.15 , pp. 901-902
    • Moulton, M.J.1    Creswell, L.L.2    Wyers, S.G.3    Actis, R.L.4    Szabo, B.A.5    Vannier, M.W.6    Pasque, M.K.7
  • 14
    • 0017624349 scopus 로고
    • A simplified model for the short-below knee stump
    • Nissan, M. (1977) A simplified model for the short-below knee stump. J Biomechanics 10, 651-658.
    • (1977) J Biomechanics , vol.10 , pp. 651-658
    • Nissan, M.1
  • 15
    • 0005808768 scopus 로고    scopus 로고
    • Solution of geometrically nonlinear problems using spatial reference and the p-version of the finite element method
    • 18-20 August, 1996, Irvine, CA. CDROM I395CD
    • Noel, A. T. and Szabo, B. A. (1996) Solution of geometrically nonlinear problems using spatial reference and the p-version of the finite element method. Proceedings of 1996 ASME Design Engineering Technical Conference, Computer Engineering Conference, 18-20 August, 1996, Irvine, CA. CDROM I395CD.
    • (1996) Proceedings of 1996 ASME Design Engineering Technical Conference, Computer Engineering Conference
    • Noel, A.T.1    Szabo, B.A.2
  • 18
    • 0026712389 scopus 로고
    • Evaluation of section sensitivity profiles and image noise in spiral CT
    • Polacin, A., Kalender, W. A. and Marchai, G. (1992) Evaluation of section sensitivity profiles and image noise in spiral CT. Radiology 185, 29-35.
    • (1992) Radiology , vol.185 , pp. 29-35
    • Polacin, A.1    Kalender, W.A.2    Marchai, G.3
  • 19
    • 0025946787 scopus 로고
    • Analysis of a below-knee patellar tendon-bearing prosthesis: A finite element study
    • Quesada, P. and Skinner, H. B. (1991) Analysis of a below-knee patellar tendon-bearing prosthesis: a finite element study J. Rehab. Res. Dev. 28(3), 1-12.
    • (1991) J. Rehab. Res. Dev. , vol.28 , Issue.3 , pp. 1-12
    • Quesada, P.1    Skinner, H.B.2
  • 20
    • 0026896837 scopus 로고
    • Interface load analysis for computer-aided design of below-knee prosthetic sockets
    • Reynolds, D. P. and Lord, M. (1992) Interface load analysis for computer-aided design of below-knee prosthetic sockets. Med. Biol. Engng Comput. 30, 419-426.
    • (1992) Med. Biol. Engng Comput. , vol.30 , pp. 419-426
    • Reynolds, D.P.1    Lord, M.2
  • 22
    • 0013549484 scopus 로고
    • Interactive 3-D image display and analysis
    • Edited by Casasent, D. P. and Tescher, A. G.
    • Robb, R. A. and Barillot, C. (1988) Interactive 3-D image display and analysis. In SPIE Proc. (Edited by Casasent, D. P. and Tescher, A. G.), Vol. 939, pp. 173-202.
    • (1988) SPIE Proc. , vol.939 , pp. 173-202
    • Robb, R.A.1    Barillot, C.2
  • 23
    • 0024738569 scopus 로고
    • Interactive display and analysis of 3-D medical images
    • Robb, R. A. and Barillot, C. (1989) Interactive display and analysis of 3-D medical images. IEEE Trans. Med. Imaging 8(3), 217-226.
    • (1989) IEEE Trans. Med. Imaging , vol.8 , Issue.3 , pp. 217-226
    • Robb, R.A.1    Barillot, C.2
  • 24
    • 0027752359 scopus 로고
    • Normal and shear stresses on a residual limb in a prosthetic socket during ambulation: Comparison of finite element results with experimental measurements
    • Sanders, J. E. and Daly, C. H. (1993) Normal and shear stresses on a residual limb in a prosthetic socket during ambulation: comparison of finite element results with experimental measurements. J. Rehab. Res. Dev. 30(2), 191-204.
    • (1993) J. Rehab. Res. Dev. , vol.30 , Issue.2 , pp. 191-204
    • Sanders, J.E.1    Daly, C.H.2
  • 27
    • 0030189273 scopus 로고    scopus 로고
    • Finite element analysis in professional practice
    • Szabo, B. A. and Actis, R. L. (1996) Finite element analysis in professional practice. Comput. Meth. Appl. Mech. Engng 133, 209-228.
    • (1996) Comput. Meth. Appl. Mech. Engng , vol.133 , pp. 209-228
    • Szabo, B.A.1    Actis, R.L.2
  • 28
    • 0000731242 scopus 로고
    • Solution of elastic-plastic stress analysis problems by the p-version of the finite element method
    • Springer, Berlin
    • Szabo, B. A., Actis, R. L. and Holzer, S. M. (1995) Solution of elastic-plastic stress analysis problems by the p-version of the finite element method. The IMA Volumes in Mathematics and its Applications, Vol. 75, pp. 395-416. Springer, Berlin.
    • (1995) The IMA Volumes in Mathematics and Its Applications , vol.75 , pp. 395-416
    • Szabo, B.A.1    Actis, R.L.2    Holzer, S.M.3
  • 30
    • 0343519619 scopus 로고
    • Stress Check™. Engineering Software Research and Development, St. Louis, MO
    • User Reference Manual (Version 1.2) (1995) Stress Check™. Engineering Software Research and Development, St. Louis, MO.
    • (1995) User Reference Manual (Version 1.2)
  • 31
    • 0001655846 scopus 로고
    • In situ evaluation of lower limb prosthesis fit by spiral computed tomography
    • Vannier, M. W., Smith, K. E., Commean, P. K. and Bhatia, G. (1995) In situ evaluation of lower limb prosthesis fit by spiral computed tomography. SPIE Proc. 2434, 438-451.
    • (1995) SPIE Proc. , vol.2434 , pp. 438-451
    • Vannier, M.W.1    Smith, K.E.2    Commean, P.K.3    Bhatia, G.4
  • 32
    • 0028258284 scopus 로고
    • Longitudinal resolution in volumetric X-ray CT - Analytical comparison between conventional and helical CT
    • Wang, G. and Vannier, M. W. (1994) Longitudinal resolution in volumetric X-ray CT - Analytical comparison between conventional and helical CT. Med. Phys. 21, 429-433.
    • (1994) Med. Phys. , vol.21 , pp. 429-433
    • Wang, G.1    Vannier, M.W.2
  • 33
    • 0026580208 scopus 로고
    • Triaxial force transducer for investigating stresses at the stump/socket interface
    • Williams, R. B., Porter D., Roberts, V. C. and Regan, J. F. (1992) Triaxial force transducer for investigating stresses at the stump/socket interface. Med. Biol. Engng Comput 30, 89-96.
    • (1992) Med. Biol. Engng Comput , vol.30 , pp. 89-96
    • Williams, R.B.1    Porter, D.2    Roberts, V.C.3    Regan, J.F.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.