Volumn 77, Issue 5, 1996, Pages 477-486

Precision of surface measurements for below-knee residua

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; ARTICLE; BELOW KNEE AMPUTATION; BODY SURFACE; CLINICAL ARTICLE; CLINICAL PROTOCOL; DIGITAL COMPUTER; FEMALE; GEOMETRY; HUMAN; INTERMETHOD COMPARISON; LEG AMPUTATION; LEG PROSTHESIS; MALE; MEASUREMENT; OPTICS; PLASTER CAST; RADIODIAGNOSIS; SPIRAL COMPUTER ASSISTED TOMOGRAPHY; THREE DIMENSIONAL IMAGING;

EID: 0030005557     PISSN: 00039993     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0003-9993(96)90037-4     Document Type: Article
Times cited : (38)

References (33)
  • 1
    • 0000968691 scopus 로고
    • A computerized system to manufacture prostheses for amputees in developing countries
    • Walsh NE, Lancaster JL, Faulkner V, Rogers WE. A computerized system to manufacture prostheses for amputees in developing countries. J Prosth Orthot 1989;1(3):165-81.
    • (1989) J Prosth Orthot , vol.1 , Issue.3 , pp. 165-181
    • Walsh, N.E.1    Lancaster, J.L.2    Faulkner, V.3    Rogers, W.E.4
  • 2
    • 0000190636 scopus 로고
    • A survey of amputees: Functional level and life satisfaction, information needs, and the prosthetist's role
    • Nielsen CC. A survey of amputees: functional level and life satisfaction, information needs, and the prosthetist's role. J Prosth Orthot 1991;3(3):125-9.
    • (1991) J Prosth Orthot , vol.3 , Issue.3 , pp. 125-129
    • Nielsen, C.C.1
  • 4
    • 0022000730 scopus 로고
    • A review of employee patterns of industrial amputees - Factors influencing rehabilitation
    • Millstein S, Bain D, Hunter GA. A review of employee patterns of industrial amputees - Factors influencing rehabilitation. Prosth Orthot Int 1985;9:69-78.
    • (1985) Prosth Orthot Int , vol.9 , pp. 69-78
    • Millstein, S.1    Bain, D.2    Hunter, G.A.3
  • 5
    • 0020575669 scopus 로고
    • Consumer concerns in prosthetics
    • Chadderton HC. Consumer concerns in prosthetics. Prosth Orthot Int 1983;7:15-6.
    • (1983) Prosth Orthot Int , vol.7 , pp. 15-16
    • Chadderton, H.C.1
  • 6
    • 0022970715 scopus 로고
    • Prescription of above-knee and below-knee prostheses
    • Rubin G, Fischer E, Dixon M. Prescription of above-knee and below-knee prostheses. Prosth Orthot Int 1986;10:117-24.
    • (1986) Prosth Orthot Int , vol.10 , pp. 117-124
    • Rubin, G.1    Fischer, E.2    Dixon, M.3
  • 7
    • 0020967529 scopus 로고
    • Life expectancy and social consequences of through-knee amputations
    • Jensen JS. Life expectancy and social consequences of through-knee amputations. Prosth Orthot Int 1983;7:113-5.
    • (1983) Prosth Orthot Int , vol.7 , pp. 113-115
    • Jensen, J.S.1
  • 8
    • 0025670475 scopus 로고
    • An evaluation of computer aided design of below-knee prosthetic sockets
    • Topper AK, Fernie GR. An evaluation of computer aided design of below-knee prosthetic sockets. Prosth Orthot Int 1990;14:136-44.
    • (1990) Prosth Orthot Int , vol.14 , pp. 136-144
    • Topper, A.K.1    Fernie, G.R.2
  • 9
    • 0022981432 scopus 로고
    • Results of the pilot phase of a clinical evaluation of computer aided design of trans-tibial prosthesis sockets
    • Holden JM, Fernie GR. Results of the pilot phase of a clinical evaluation of computer aided design of trans-tibial prosthesis sockets. Prosthet Orthot Int 1986;10:142-8.
    • (1986) Prosthet Orthot Int , vol.10 , pp. 142-148
    • Holden, J.M.1    Fernie, G.R.2
  • 11
    • 0027738084 scopus 로고
    • Report on the evaluation of the VA/ SEATTLE below-knee prosthesis
    • Ellepola W, Sheredos SJ. Report on the evaluation of the VA/ SEATTLE below-knee prosthesis. J Rehabil Res Dev 1993;30:260-6.
    • (1993) J Rehabil Res Dev , vol.30 , pp. 260-266
    • Ellepola, W.1    Sheredos, S.J.2
  • 12
    • 34548089639 scopus 로고
    • Clinical research
    • Lunsford TR. Clinical research. J Prosth Orthot 1993;5(4):28-31.
    • (1993) J Prosth Orthot , vol.5 , Issue.4 , pp. 28-31
    • Lunsford, T.R.1
  • 13
    • 0003317919 scopus 로고
    • Computer designed prosthetic socket from analysis of computed tomography data
    • Faulkner VW, Walsh NE. Computer designed prosthetic socket from analysis of computed tomography data. J Prosth Orthot 1989;1(3):154-64.
    • (1989) J Prosth Orthot , vol.1 , Issue.3 , pp. 154-164
    • Faulkner, V.W.1    Walsh, N.E.2
  • 14
    • 0025351273 scopus 로고
    • Spiral volumetric CT with single-breath-hold technique, continuous transport, and continuous scanner rotation
    • Kalender WA, Seissler W, Klotz E, Vock P. Spiral volumetric CT with single-breath-hold technique, continuous transport, and continuous scanner rotation. Radiology 1990;176:181-3.
    • (1990) Radiology , vol.176 , pp. 181-183
    • Kalender, W.A.1    Seissler, W.2    Klotz, E.3    Vock, P.4
  • 15
    • 0026048199 scopus 로고
    • Physical performance characteristics of spiral CT scanning
    • Kalender WA, Polacin A. Physical performance characteristics of spiral CT scanning. Med Phys 1991;18:910-5.
    • (1991) Med Phys , vol.18 , pp. 910-915
    • Kalender, W.A.1    Polacin, A.2
  • 16
    • 0015683426 scopus 로고
    • Calculating volume change in a swollen extremity from surface measurements
    • Lennihan R Jr, Mackerth M. Calculating volume change in a swollen extremity from surface measurements. Am J Surg 1973;126:649-52.
    • (1973) Am J Surg , vol.126 , pp. 649-652
    • Lennihan Jr., R.1    Mackerth, M.2
  • 17
    • 0018068564 scopus 로고
    • An instrument for monitoring stump oedema and shrinkage in amputees
    • Fernie GR, Holliday PJ, Lobb RJ. An instrument for monitoring stump oedema and shrinkage in amputees. Prosth Orthot Int 1978;2:69-78.
    • (1978) Prosth Orthot Int , vol.2 , pp. 69-78
    • Fernie, G.R.1    Holliday, P.J.2    Lobb, R.J.3
  • 18
    • 0020050715 scopus 로고
    • Volume fluctuations in the residual limbs of lower limb amputees
    • Fernie GR, Holliday PJ. Volume fluctuations in the residual limbs of lower limb amputees. Arch Phys Med Rehabil 1982;63:162-5.
    • (1982) Arch Phys Med Rehabil , vol.63 , pp. 162-165
    • Fernie, G.R.1    Holliday, P.J.2
  • 20
    • 0024423366 scopus 로고
    • Lower limb oedema after arterial reconstructive surgery
    • Persson NH, Takolander R, Bergqvist D. Lower limb oedema after arterial reconstructive surgery. Acta Chir Scand 1989;155:259-66.
    • (1989) Acta Chir Scand , vol.155 , pp. 259-266
    • Persson, N.H.1    Takolander, R.2    Bergqvist, D.3
  • 21
    • 0026559488 scopus 로고
    • Development and clinical evaluation of a computerized limb volume measurement system (CLEMS)
    • Bednarczyk JH, Hershler C, Cooper DG. Development and clinical evaluation of a computerized limb volume measurement system (CLEMS). Arch Phys Med Rehabil 1992;73:60-3.
    • (1992) Arch Phys Med Rehabil , vol.73 , pp. 60-63
    • Bednarczyk, J.H.1    Hershler, C.2    Cooper, D.G.3
  • 27
    • 0010237932 scopus 로고
    • Validation of spiral computed tomography and optical surface scanning for 3D limb prosthesis design
    • Image Society; 1994 June 12-17; Tucson (AZ)
    • Commean PK, Smith KE, Bhatia G, Vannier MW. Validation of spiral computed tomography and optical surface scanning for 3D limb prosthesis design. Proceedings IMAGE VII Conference, Image Society; 1994 June 12-17; Tucson (AZ), 1994:369-81.
    • (1994) Proceedings IMAGE VII Conference , pp. 369-381
    • Commean, P.K.1    Smith, K.E.2    Bhatia, G.3    Vannier, M.W.4
  • 29
    • 0023690539 scopus 로고
    • Three-dimensional measurement accuracy of skull surface landmarks
    • Hildebolt C, Vannier MW. Three-dimensional measurement accuracy of skull surface landmarks. Am J Phys Anthropol 1988;76:497-503.
    • (1988) Am J Phys Anthropol , vol.76 , pp. 497-503
    • Hildebolt, C.1    Vannier, M.W.2
  • 31
    • 0024760875 scopus 로고
    • Analyze: A comprehensive, operator-interactive software package for multidimensional medical image display and analysis
    • Robb RA, Hanson DP, Karwoski RA, Larson AG, Workman EL, Stacy MC. Analyze: a comprehensive, operator-interactive software package for multidimensional medical image display and analysis. Comput Med Imaging Graph 1989;13:433-54.
    • (1989) Comput Med Imaging Graph , vol.13 , pp. 433-454
    • Robb, R.A.1    Hanson, D.P.2    Karwoski, R.A.3    Larson, A.G.4    Workman, E.L.5    Stacy, M.C.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.