메뉴 건너뛰기




Volumn 13, Issue 2, 1997, Pages 55-60

Dose rate correction factors for diamond detectors for megavoltage photon beams

Author keywords

Diamond detectors; Radiotherapy dosimetry

Indexed keywords

ARTICLE; DEVICE; DOSIMETRY; ENERGY; IONIZATION CHAMBER; MEGAVOLTAGE RADIATION; PHOTON; RADIATION DEPTH DOSE; RADIATION DOSE; RADIOSURGERY;

EID: 0030987651     PISSN: 11201797     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (14)

References (13)
  • 1
    • 0030026160 scopus 로고    scopus 로고
    • A comparison of dosimetric techniques in stereotactic radiosurgery
    • Heydarian M, Hoban PW and Beddoe AH. A comparison of dosimetric techniques in stereotactic radiosurgery. Phys Med Biol 1996: 41; 93-110.
    • (1996) Phys Med Biol , vol.41 , pp. 93-110
    • Heydarian, M.1    Hoban, P.W.2    Beddoe, A.H.3
  • 3
    • 0027393650 scopus 로고
    • Application of a natural diamond detector for the measurement of relative dose, distributions in radiotherapy
    • Vatnisky S and Järvinen H. Application of a natural diamond detector for the measurement of relative dose, distributions in radiotherapy. Phys Med Biol 1993: 38; 173-84.
    • (1993) Phys Med Biol , vol.38 , pp. 173-184
    • Vatnisky, S.1    Järvinen, H.2
  • 4
    • 0028049726 scopus 로고
    • Dose rate dependence of a PTW diamond detector in the dosimetry of a 6 MV photon beam
    • Hoban PW, Heydarian M, Beckham WA and Beddoe AH. Dose rate dependence of a PTW diamond detector in the dosimetry of a 6 MV photon beam. Phys Med Biol 1994: 39; 1219-1229.
    • (1994) Phys Med Biol , vol.39 , pp. 1219-1229
    • Hoban, P.W.1    Heydarian, M.2    Beckham, W.A.3    Beddoe, A.H.4
  • 5
    • 0029004417 scopus 로고
    • Evaluation of the dosemetric characteristics of a diamond detector for photon beam measurements
    • Rustgi SN. Evaluation of the dosemetric characteristics of a diamond detector for photon beam measurements Med Phys 1995: 22; 567-70.
    • (1995) Med Phys , vol.22 , pp. 567-570
    • Rustgi, S.N.1
  • 6
    • 0019498789 scopus 로고
    • Dosimetry with a diamond detector acting as a resistor
    • Burgemeister EA. Dosimetry with a diamond detector acting as a resistor. Phys Med Biol 1981: 26; 269-75.
    • (1981) Phys Med Biol , vol.26 , pp. 269-275
    • Burgemeister, E.A.1
  • 7
    • 0027164862 scopus 로고
    • Evaluation of a PTW diamond detector for electron beam measurements
    • Heydarian M, Hoban P W, Beckham W A, and Beddoe A H. Evaluation of a PTW diamond detector for electron beam measurements. Phys Med Biol 1993: 38; 1035-42.
    • (1993) Phys Med Biol , vol.38 , pp. 1035-1042
    • Heydarian, M.1    Hoban, P.W.2    Beckham, W.A.3    Beddoe, A.H.4
  • 8
    • 0025114680 scopus 로고
    • Diamond detectors in relative dosimetry of photon, electron and proton radiation fields
    • Khrunov BS, Martynov SS, Vatnisky SM, et al. Diamond detectors in relative dosimetry of photon, electron and proton radiation fields Radiation Protection Dosimetry 1990: 33; 155-7.
    • (1990) Radiation Protection Dosimetry , vol.33 , pp. 155-157
    • Khrunov, B.S.1    Martynov, S.S.2    Vatnisky, S.M.3
  • 9
    • 0028919685 scopus 로고
    • Application of solid state detectors for dosimetry of therapeutic proton beams
    • Vatnisky S, Miller D, Siebers J and Moyers M. Application of solid state detectors for dosimetry of therapeutic proton beams. Med Phys 1995: 22; 469-73.
    • (1995) Med Phys , vol.22 , pp. 469-473
    • Vatnisky, S.1    Miller, D.2    Siebers, J.3    Moyers, M.4
  • 10
    • 0027212572 scopus 로고
    • Linearity with dose rate of low resistivity p-type silicon semiconductor detectors
    • Grusell E and Rikner G. Linearity with dose rate of low resistivity p-type silicon semiconductor detectors. Phys Med Biol 1993: 38; 785-92.
    • (1993) Phys Med Biol , vol.38 , pp. 785-792
    • Grusell, E.1    Rikner, G.2
  • 11
    • 0021043262 scopus 로고
    • Effects of Radiation damage on p-type silicon detectors
    • Rikner G and Grusell E. Effects of Radiation damage on p-type silicon detectors. Phys Med Biol 1983: 28; 1261-7.
    • (1983) Phys Med Biol , vol.28 , pp. 1261-1267
    • Rikner, G.1    Grusell, E.2
  • 12
    • 0024424112 scopus 로고
    • Collapsed cone convolution of radiant energy for photon dose calculation in heterogeneous media
    • Ahnesjo A. Collapsed cone convolution of radiant energy for photon dose calculation in heterogeneous media. Med Phys 1989: 16; 577-92.
    • (1989) Med Phys , vol.16 , pp. 577-592
    • Ahnesjo, A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.