-
1
-
-
0030026160
-
A comparison of dosimetric techniques in stereotactic radiosurgery
-
Heydarian M, Hoban PW and Beddoe AH. A comparison of dosimetric techniques in stereotactic radiosurgery. Phys Med Biol 1996: 41; 93-110.
-
(1996)
Phys Med Biol
, vol.41
, pp. 93-110
-
-
Heydarian, M.1
Hoban, P.W.2
Beddoe, A.H.3
-
3
-
-
0027393650
-
Application of a natural diamond detector for the measurement of relative dose, distributions in radiotherapy
-
Vatnisky S and Järvinen H. Application of a natural diamond detector for the measurement of relative dose, distributions in radiotherapy. Phys Med Biol 1993: 38; 173-84.
-
(1993)
Phys Med Biol
, vol.38
, pp. 173-184
-
-
Vatnisky, S.1
Järvinen, H.2
-
4
-
-
0028049726
-
Dose rate dependence of a PTW diamond detector in the dosimetry of a 6 MV photon beam
-
Hoban PW, Heydarian M, Beckham WA and Beddoe AH. Dose rate dependence of a PTW diamond detector in the dosimetry of a 6 MV photon beam. Phys Med Biol 1994: 39; 1219-1229.
-
(1994)
Phys Med Biol
, vol.39
, pp. 1219-1229
-
-
Hoban, P.W.1
Heydarian, M.2
Beckham, W.A.3
Beddoe, A.H.4
-
5
-
-
0029004417
-
Evaluation of the dosemetric characteristics of a diamond detector for photon beam measurements
-
Rustgi SN. Evaluation of the dosemetric characteristics of a diamond detector for photon beam measurements Med Phys 1995: 22; 567-70.
-
(1995)
Med Phys
, vol.22
, pp. 567-570
-
-
Rustgi, S.N.1
-
6
-
-
0019498789
-
Dosimetry with a diamond detector acting as a resistor
-
Burgemeister EA. Dosimetry with a diamond detector acting as a resistor. Phys Med Biol 1981: 26; 269-75.
-
(1981)
Phys Med Biol
, vol.26
, pp. 269-275
-
-
Burgemeister, E.A.1
-
7
-
-
0027164862
-
Evaluation of a PTW diamond detector for electron beam measurements
-
Heydarian M, Hoban P W, Beckham W A, and Beddoe A H. Evaluation of a PTW diamond detector for electron beam measurements. Phys Med Biol 1993: 38; 1035-42.
-
(1993)
Phys Med Biol
, vol.38
, pp. 1035-1042
-
-
Heydarian, M.1
Hoban, P.W.2
Beckham, W.A.3
Beddoe, A.H.4
-
8
-
-
0025114680
-
Diamond detectors in relative dosimetry of photon, electron and proton radiation fields
-
Khrunov BS, Martynov SS, Vatnisky SM, et al. Diamond detectors in relative dosimetry of photon, electron and proton radiation fields Radiation Protection Dosimetry 1990: 33; 155-7.
-
(1990)
Radiation Protection Dosimetry
, vol.33
, pp. 155-157
-
-
Khrunov, B.S.1
Martynov, S.S.2
Vatnisky, S.M.3
-
9
-
-
0028919685
-
Application of solid state detectors for dosimetry of therapeutic proton beams
-
Vatnisky S, Miller D, Siebers J and Moyers M. Application of solid state detectors for dosimetry of therapeutic proton beams. Med Phys 1995: 22; 469-73.
-
(1995)
Med Phys
, vol.22
, pp. 469-473
-
-
Vatnisky, S.1
Miller, D.2
Siebers, J.3
Moyers, M.4
-
10
-
-
0027212572
-
Linearity with dose rate of low resistivity p-type silicon semiconductor detectors
-
Grusell E and Rikner G. Linearity with dose rate of low resistivity p-type silicon semiconductor detectors. Phys Med Biol 1993: 38; 785-92.
-
(1993)
Phys Med Biol
, vol.38
, pp. 785-792
-
-
Grusell, E.1
Rikner, G.2
-
11
-
-
0021043262
-
Effects of Radiation damage on p-type silicon detectors
-
Rikner G and Grusell E. Effects of Radiation damage on p-type silicon detectors. Phys Med Biol 1983: 28; 1261-7.
-
(1983)
Phys Med Biol
, vol.28
, pp. 1261-1267
-
-
Rikner, G.1
Grusell, E.2
-
12
-
-
0024424112
-
Collapsed cone convolution of radiant energy for photon dose calculation in heterogeneous media
-
Ahnesjo A. Collapsed cone convolution of radiant energy for photon dose calculation in heterogeneous media. Med Phys 1989: 16; 577-92.
-
(1989)
Med Phys
, vol.16
, pp. 577-592
-
-
Ahnesjo, A.1
|