메뉴 건너뛰기




Volumn 68, Issue 2, 1997, Pages 340-345

The performance of 10 different methods for the estimation of sperm concentration

Author keywords

Latex beads; Male infertility; Quality control; Sperm counting

Indexed keywords

ARTICLE; HUMAN; HUMAN CELL; MALE INFERTILITY; PRIORITY JOURNAL; QUALITY CONTROL; SEMINAL PLASMA; SPERMATOZOON COUNT;

EID: 0030845131     PISSN: 00150282     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0015-0282(97)81526-9     Document Type: Article
Times cited : (68)

References (21)
  • 1
    • 0011369679 scopus 로고
    • Assessment of sperm concentration
    • Hedon B, Bringer J, Mares P, editors. Fertility and Sterility, a Current Overview; 1995 September 17-22; Montpellier (France). London: The Parthenon Publishing Group
    • Comhaire F, Depoorter B, Vermeulen L, Schoonjans F. Assessment of sperm concentration. In: Hedon B, Bringer J, Mares P, editors. Fertility and sterility, a current overview. Proceedings of the 15th World Congress on Fertility and Sterility; 1995 September 17-22; Montpellier (France). London: The Parthenon Publishing Group, 1995:297-301.
    • (1995) Proceedings of the 15th World Congress on Fertility and Sterility , pp. 297-301
    • Comhaire, F.1    Depoorter, B.2    Vermeulen, L.3    Schoonjans, F.4
  • 4
    • 0030057691 scopus 로고    scopus 로고
    • Manual versus computer-automated semen analyses. Part I. Comparison of counting chambers
    • Johnson JE, Boone WR, Blackhurst DW. Manual versus computer-automated semen analyses. Part I. Comparison of counting chambers. Fertil Steril 1996;65:150-5.
    • (1996) Fertil Steril , vol.65 , pp. 150-155
    • Johnson, J.E.1    Boone, W.R.2    Blackhurst, D.W.3
  • 5
    • 0024476708 scopus 로고
    • A technical note on diluting semen for haemocytometeric determination of sperm concentration
    • Mortimer D, Shu MA, Tan R, Mortimer ST. A technical note on diluting semen for haemocytometeric determination of sperm concentration. Hum Reprod 1989;4:166-8.
    • (1989) Hum Reprod , vol.4 , pp. 166-168
    • Mortimer, D.1    Shu, M.A.2    Tan, R.3    Mortimer, S.T.4
  • 7
    • 0023029102 scopus 로고
    • Standardization and quality control of sperm concentration and sperm motility counts in semen analysis
    • Mortimer D, Shu MA, Tan R. Standardization and quality control of sperm concentration and sperm motility counts in semen analysis. Hum Reprod 1986; 1:299-303.
    • (1986) Hum Reprod , vol.1 , pp. 299-303
    • Mortimer, D.1    Shu, M.A.2    Tan, R.3
  • 8
    • 0024420289 scopus 로고
    • Quality control during the conventional analysis of semen, an essential exercise
    • Dunphy BC, Kay R, Barratt CL, Cooke ID. Quality control during the conventional analysis of semen, an essential exercise. J Androl 1989; 10:378-85.
    • (1989) J Androl , vol.10 , pp. 378-385
    • Dunphy, B.C.1    Kay, R.2    Barratt, C.L.3    Cooke, I.D.4
  • 9
    • 0024439309 scopus 로고
    • Bias to routine semen analysis by uncontrolled changes in laboratory environment - Detection by long-term sampling of monthly means for quality control
    • Knuth UA, Neuwinger J, Nieschlag E. Bias to routine semen analysis by uncontrolled changes in laboratory environment - detection by long-term sampling of monthly means for quality control. Int J Androl 1989; 12:375-83.
    • (1989) Int J Androl , vol.12 , pp. 375-383
    • Knuth, U.A.1    Neuwinger, J.2    Nieschlag, E.3
  • 10
    • 0025158279 scopus 로고
    • External quality control in the andrology laboratory: An experimental multicenter trial
    • Neuwinger J, Behre HM, Nieschlag E. External quality control in the andrology laboratory: an experimental multicenter trial. Fertil Steril 1990; 54:308-14.
    • (1990) Fertil Steril , vol.54 , pp. 308-314
    • Neuwinger, J.1    Behre, H.M.2    Nieschlag, E.3
  • 12
    • 0029048336 scopus 로고
    • Implementing comprehensive quality control in the andrology laboratory
    • Clements S, Cooke ID, Barratt CL. Implementing comprehensive quality control in the andrology laboratory. Hum Reprod 1995; 10:2096-106.
    • (1995) Hum Reprod , vol.10 , pp. 2096-2106
    • Clements, S.1    Cooke, I.D.2    Barratt, C.L.3
  • 13
    • 0028940385 scopus 로고
    • External quality assessment for semen analysis and sperm antibody detection: Results of a pilot scheme
    • Matson PL. External quality assessment for semen analysis and sperm antibody detection: results of a pilot scheme. Hum Reprod 1995; 10:620-5.
    • (1995) Hum Reprod , vol.10 , pp. 620-625
    • Matson, P.L.1
  • 14
    • 0029126711 scopus 로고
    • Evaluating the accuracy of different sperm counting chambers by performing strict counts of photographed beads
    • Shiran E, Stoller J, Blumenfeld Z, Feigin PD, Makler A. Evaluating the accuracy of different sperm counting chambers by performing strict counts of photographed beads. J Assist Reprod Genet 1995; 12:434-42.
    • (1995) J Assist Reprod Genet , vol.12 , pp. 434-442
    • Shiran, E.1    Stoller, J.2    Blumenfeld, Z.3    Feigin, P.D.4    Makler, A.5
  • 15
    • 0027421751 scopus 로고
    • Quality assurance for sperm concentration using latex beads
    • Peters AJ, Zaneveld LJ, Jeyendran RS. Quality assurance for sperm concentration using latex beads. Fertil Steril 1993;4:702-5.
    • (1993) Fertil Steril , vol.4 , pp. 702-705
    • Peters, A.J.1    Zaneveld, L.J.2    Jeyendran, R.S.3
  • 16
    • 0024060452 scopus 로고
    • Validation of a singlestep procedure for the objective assessment of sperm motility characteristics
    • Hinting A, Schoonjans F, Comhaire F. Validation of a singlestep procedure for the objective assessment of sperm motility characteristics. Int J Androl 1988; 11:277-87.
    • (1988) Int J Androl , vol.11 , pp. 277-287
    • Hinting, A.1    Schoonjans, F.2    Comhaire, F.3
  • 18
    • 0018408116 scopus 로고
    • A simple inexpensive method for the objective assessment of human sperm movement characteristics
    • Overstreet JW, Katz DF, Hanson FW, Fonseca JR. A simple inexpensive method for the objective assessment of human sperm movement characteristics. Fertil Steril 1979;31:162-72.
    • (1979) Fertil Steril , vol.31 , pp. 162-172
    • Overstreet, J.W.1    Katz, D.F.2    Hanson, F.W.3    Fonseca, J.R.4
  • 19
    • 0018864776 scopus 로고
    • The improved ten-micrometer chamber for rapid sperm count and motility evaluation
    • Makler A. The improved ten-micrometer chamber for rapid sperm count and motility evaluation. Fertil Steril 1980; 33:337-8.
    • (1980) Fertil Steril , vol.33 , pp. 337-338
    • Makler, A.1
  • 21
    • 84908219488 scopus 로고
    • Statistical method for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical method for assessing agreement between two methods of clinical measurement. Lancet 1986; 1:307-10.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.