메뉴 건너뛰기




Volumn 65, Issue 1, 1996, Pages 150-155

Manual versus computer-automated semen analyses. Part I. Comparison of counting chambers

Author keywords

beads; CASA; counting chambers; hemacytometer; Makler Chamber; MicroCell Chamber; quality control; Sperm; validation

Indexed keywords

ARTICLE; AUTOMATION; CLINICAL PROTOCOL; COMPUTER; CONTROLLED STUDY; CYTOMETRY; HUMAN; HUMAN CELL; MALE; MALE INFERTILITY; MANUAL LABOR; PRIORITY JOURNAL; QUALITY CONTROL; SEMEN ANALYSIS; SPERMATOZOON COUNT; SPERMATOZOON DENSITY; SPERMATOZOON MOTILITY;

EID: 0030057691     PISSN: 00150282     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0015-0282(16)58043-1     Document Type: Article
Times cited : (43)

References (13)
  • 1
    • 0006511021 scopus 로고
    • The error of estimate of the blood cell count as made with the hemacytometer
    • J. Berkson T.B. Magath M. Hurn The error of estimate of the blood cell count as made with the hemacytometer Am J Physiol 128 1940 309 323
    • (1940) Am J Physiol , vol.128 , pp. 309-323
    • Berkson, J.1    Magath, T.B.2    Hurn, M.3
  • 2
    • 84957367657 scopus 로고
    • The errors of some haematological methods as they are used in a routine laboratory
    • R. Biggs R.I. MacMillan The errors of some haematological methods as they are used in a routine laboratory J Clin Pathol 1 1948 269 287
    • (1948) J Clin Pathol , vol.1 , pp. 269-287
    • Biggs, R.1    MacMillan, R.I.2
  • 3
    • 0026570826 scopus 로고
    • Standardization and comparability of CASA instruments
    • R.O. Davis D.F. Katz Standardization and comparability of CASA instruments J Androl 13 1992 81 86
    • (1992) J Androl , vol.13 , pp. 81-86
    • Davis, R.O.1    Katz, D.F.2
  • 4
    • 0025252974 scopus 로고
    • Determination of the precision of an automated semen analyzer
    • J.E. Johnson W.R. Boone S.S. Shapiro Determination of the precision of an automated semen analyzer Lab Med 21 1990 33 38
    • (1990) Lab Med , vol.21 , pp. 33-38
    • Johnson, J.E.1    Boone, W.R.2    Shapiro, S.S.3
  • 5
    • 0024206386 scopus 로고
    • Evaluation of the Cell Soft automated semen analysis system in a routine laboratory setting
    • D. Mortimer N. Goel M.A. Shu Evaluation of the Cell Soft automated semen analysis system in a routine laboratory setting Fertil Steril 50 1988 960 968
    • (1988) Fertil Steril , vol.50 , pp. 960-968
    • Mortimer, D.1    Goel, N.2    Shu, M.A.3
  • 6
    • 0003689119 scopus 로고
    • Statistical principles in experimental design
    • B.J. Winer D.R. Brown K.M. Michels Statistical principles in experimental design 3rd ed. 1991 McGraw-Hill New York
    • (1991)
    • Winer, B.J.1    Brown, D.R.2    Michels, K.M.3
  • 7
    • 85113042260 scopus 로고
    • SAS Institute Inc SAS/STAT user’s guide, release 6.03 edition 1988 SAS Institute Inc Cary (NC)
    • (1988)
    • SAS Institute Inc1
  • 9
    • 0024420289 scopus 로고
    • Quality control during the conventional analysis of semen, an essential exercise
    • B.C. Dunphy R. Kay C.L.R. Barratt I.D. Cooke Quality control during the conventional analysis of semen, an essential exercise J Androl 10 1989 378 385
    • (1989) J Androl , vol.10 , pp. 378-385
    • Dunphy, B.C.1    Kay, R.2    Barratt, C.L.R.3    Cooke, I.D.4
  • 10
    • 0023029102 scopus 로고
    • Standardization and quality control of sperm concentration and sperm motility counts in semen analysis
    • D. Mortimer M.A. Shu R. Tan Standardization and quality control of sperm concentration and sperm motility counts in semen analysis Hum Reprod 1 1986 299 303
    • (1986) Hum Reprod , vol.1 , pp. 299-303
    • Mortimer, D.1    Shu, M.A.2    Tan, R.3
  • 11
    • 0020612205 scopus 로고
    • Errors inherent in the performance of a routine semen analysis
    • A.M. Jequier E.B. Ukombe Errors inherent in the performance of a routine semen analysis Br J Urol 55 1983 434 436
    • (1983) Br J Urol , vol.55 , pp. 434-436
    • Jequier, A.M.1    Ukombe, E.B.2
  • 12
    • 0000670362 scopus 로고
    • Factors affecting haemocytometer counts of sperm concentration in human semen
    • M. Freund B. Carol Factors affecting haemocytometer counts of sperm concentration in human semen J Reprod Fertil 8 1964 149 155
    • (1964) J Reprod Fertil , vol.8 , pp. 149-155
    • Freund, M.1    Carol, B.2
  • 13
    • 0025298527 scopus 로고
    • The influence of chamber characteristics on the reliability of sperm concentration and movement measurements obtained by manual and videomicrographic analysis
    • K.A. Ginsburg D.R. Armant The influence of chamber characteristics on the reliability of sperm concentration and movement measurements obtained by manual and videomicrographic analysis Fertil Steril 53 1990 882 887
    • (1990) Fertil Steril , vol.53 , pp. 882-887
    • Ginsburg, K.A.1    Armant, D.R.2