메뉴 건너뛰기




Volumn 3, Issue 3, 1997, Pages 352-355

Rapid recovery of Mycobacterium tuberculosis complex from clinical specimens using the BACTEC 9000 MB system, a new automated fluorimetric technique

Author keywords

BACTEC 9000; Mycobacterium tuberculosis complex; Rapid diagnosis of tuberculosis

Indexed keywords

ARTICLE; AUTOMATION; CLINICAL TRIAL; CONTAMINATION; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; DIAGNOSTIC ACCURACY; FLUOROMETRY; HUMAN; INTERMETHOD COMPARISON; LABORATORY DIAGNOSIS; MAJOR CLINICAL STUDY; MICROBIOLOGY; MYCOBACTERIUM TUBERCULOSIS; PRIORITY JOURNAL; TIME; TUBERCULOSIS;

EID: 0030834218     PISSN: 1198743X     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.1469-0691.1997.tb00625.x     Document Type: Article
Times cited : (7)

References (11)
  • 1
    • 0025737457 scopus 로고
    • Tuberculosis in patients with human immunodeficiency virus infection
    • Barnes PF, Bloch AB, Davidson PT, Snider DE Jr. Tuberculosis in patients with human immunodeficiency virus infection. N Engl J Med 1991; 324. 1644-50.
    • (1991) N Engl J Med , vol.324 , pp. 1644-1650
    • Barnes, P.F.1    Bloch, A.B.2    Davidson, P.T.3    Snider Jr., D.E.4
  • 4
    • 0025366722 scopus 로고
    • Comparison of improved BACTEC and Löwenstein-Jensen media for culture of mycobacteria from clinical specimens
    • Anargyros P, Astill DSJ, Lim ISL. Comparison of improved BACTEC and Löwenstein-Jensen media for culture of mycobacteria from clinical specimens. J Clin Microbiol 1990; 28:1288-91.
    • (1990) J Clin Microbiol , vol.28 , pp. 1288-1291
    • Anargyros, P.1    Astill, D.S.J.2    Lim, I.S.L.3
  • 5
    • 0002836279 scopus 로고
    • Mycobacterium
    • Murray PR, Baron EJ, Pfaller MA, Tenover FC, Yolken RH, eds. Washington, DC: ASM Press
    • Nolte FS, Metchock B. Mycobacterium. In: Murray PR, Baron EJ, Pfaller MA, Tenover FC, Yolken RH, eds. Manual of clinical microbiology, 6th edn. Washington, DC: ASM Press, 1995: 400-37.
    • (1995) Manual of Clinical Microbiology, 6th Edn. , pp. 400-437
    • Nolte, F.S.1    Metchock, B.2
  • 7
    • 0029841359 scopus 로고    scopus 로고
    • Comparison of fluorescent BACTEC 9000 MB system, Septi-Chek AFB system, and Lowenstein-Jensen medium for detection of mycobacteria
    • Van Griethuysen AJ, Jansz AR, Buiting AGM. Comparison of fluorescent BACTEC 9000 MB system, Septi-Chek AFB system, and Lowenstein-Jensen medium for detection of mycobacteria. J Clin Microbiol 1996; 34: 2391-4.
    • (1996) J Clin Microbiol , vol.34 , pp. 2391-2394
    • Van Griethuysen, A.J.1    Jansz, A.R.2    Buiting, A.G.M.3
  • 8
    • 0028216297 scopus 로고
    • Application of new technology to the detection, identification, and antimicrobial susceptibility testing of mycobacteria
    • Pfaller MA. Application of new technology to the detection, identification, and antimicrobial susceptibility testing of mycobacteria. AmJ Clin Pathol 1994; 101: 329-37.
    • (1994) AmJ Clin Pathol , vol.101 , pp. 329-337
    • Pfaller, M.A.1
  • 11
    • 0029759350 scopus 로고    scopus 로고
    • Comparison of mycobacteria growth indicator tube with BACTEC 460 for detection and recovery of mycobacteria from clinical specimens
    • Badak FZ, Kiska DL, Setterquist S, Hartley C, O'Connell MA, Hopfer RL. Comparison of mycobacteria growth indicator tube with BACTEC 460 for detection and recovery of mycobacteria from clinical specimens. J Clin Microbiol 1996; 34: 2236-9.
    • (1996) J Clin Microbiol , vol.34 , pp. 2236-2239
    • Badak, F.Z.1    Kiska, D.L.2    Setterquist, S.3    Hartley, C.4    O'Connell, M.A.5    Hopfer, R.L.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.