메뉴 건너뛰기




Volumn 34, Issue 10, 1996, Pages 2391-2394

Comparison of fluorescent BACTEC 9000 MB system, Septi-Chek AFB system, and Lowenstein-Jensen medium for detection of mycobacteria

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; BACTERIUM CONTAMINATION; BACTERIUM CULTURE; BACTERIUM DETECTION; BACTERIUM ISOLATION; CONTROLLED STUDY; CULTURE MEDIUM; FLUORESCENCE; HUMAN; HUMAN TISSUE; INTERMETHOD COMPARISON; MYCOBACTERIOSIS; MYCOBACTERIUM INTRACELLULARE AVIUM; MYCOBACTERIUM TUBERCULOSIS; PRIORITY JOURNAL;

EID: 0029841359     PISSN: 00951137     EISSN: None     Source Type: Journal    
DOI: 10.1128/jcm.34.10.2391-2394.1996     Document Type: Article
Times cited : (42)

References (26)
  • 2
    • 0025366722 scopus 로고
    • Comparison of improved BACTEC and Lowenstein-Jensen media for culture of mycobacteria from clinical specimens
    • Anargyros, P., D. S. Astill, and I. S. Lim. 1990. Comparison of improved BACTEC and Lowenstein-Jensen media for culture of mycobacteria from clinical specimens. J. Clin. Microbiol. 28:1288-1291.
    • (1990) J. Clin. Microbiol. , vol.28 , pp. 1288-1291
    • Anargyros, P.1    Astill, D.S.2    Lim, I.S.3
  • 4
    • 0002788967 scopus 로고    scopus 로고
    • Clinical microscopy
    • P. R. Murray, E. J. Baron, M. A. Pfaller, F. C. Tenover, and R. H. Yolken (ed.), American Society for Microbiology, Washington, D.C.
    • Chapin, K. Clinical microscopy, p. 33-51. In P. R. Murray, E. J. Baron, M. A. Pfaller, F. C. Tenover, and R. H. Yolken (ed.), Manual of clinical microbiology, 6th ed. American Society for Microbiology, Washington, D.C.
    • Manual of Clinical Microbiology, 6th Ed. , pp. 33-51
    • Chapin, K.1
  • 6
    • 0025330078 scopus 로고
    • Evaluation of a new biphasic culture system for the recovery of mycobacteria
    • Giger, T., and H. J. Burkardt. 1990. Evaluation of a new biphasic culture system for the recovery of mycobacteria. Eur. J. Clin. Microbiol. Infect. Dis. 9:428-431.
    • (1990) Eur. J. Clin. Microbiol. Infect. Dis. , vol.9 , pp. 428-431
    • Giger, T.1    Burkardt, H.J.2
  • 7
    • 9544250164 scopus 로고
    • The many uses of chi-square
    • R. C. Elston and W. D. Johnson (ed.), F. A. Davis Company, Philadelphia
    • Elston, R. C., and W. D. Johnson. 1987. The many uses of chi-square, p. 155-181. In R. C. Elston and W. D. Johnson (ed.), Essentials of biostatistics, F. A. Davis Company, Philadelphia.
    • (1987) Essentials of Biostatistics , pp. 155-181
    • Elston, R.C.1    Johnson, W.D.2
  • 10
    • 0023765975 scopus 로고
    • Improved detection of Mycobacterium avium complex with the Bactec radiometric system
    • Hoffner, S. E. 1988. Improved detection of Mycobacterium avium complex with the Bactec radiometric system. Diagn. Microbiol. Infect. Dis. 10:1-6.
    • (1988) Diagn. Microbiol. Infect. Dis. , vol.10 , pp. 1-6
    • Hoffner, S.E.1
  • 11
    • 0026564290 scopus 로고
    • A biphasic system for primary isolation of mycobacteria compared to solid medium and broth culture
    • Hoffner, S. E., M. Haile, and G. Källenius. 1992. A biphasic system for primary isolation of mycobacteria compared to solid medium and broth culture. J. Med. Microbiol. 37:332-334.
    • (1992) J. Med. Microbiol. , vol.37 , pp. 332-334
    • Hoffner, S.E.1    Haile, M.2    Källenius, G.3
  • 14
    • 0029042440 scopus 로고
    • Selective utilization of DNA probes for identification of Mycobacterium species on the basis of cord formation in primary BACTEC 12B cultures
    • Kaminski, D. A., and D. J. Hardy. 1995. Selective utilization of DNA probes for identification of Mycobacterium species on the basis of cord formation in primary BACTEC 12B cultures. J. Clin. Microbiol. 33:1548-1550.
    • (1995) J. Clin. Microbiol. , vol.33 , pp. 1548-1550
    • Kaminski, D.A.1    Hardy, D.J.2
  • 15
    • 0022388271 scopus 로고
    • Improved detection times for Mycobacterium avium complex and Mycobacterium tuberculosis with the BACTEC radiometric system
    • Kirihara, J. M., S. L. Hillier, and M. B. Coyle. 1985. Improved detection times for Mycobacterium avium complex and Mycobacterium tuberculosis with the BACTEC radiometric system. J. Clin. Microbiol. 22:841-845.
    • (1985) J. Clin. Microbiol. , vol.22 , pp. 841-845
    • Kirihara, J.M.1    Hillier, S.L.2    Coyle, M.B.3
  • 16
    • 0020623666 scopus 로고
    • Comparison of a radiometric method (BACTEC) and conventional culture media for recovery of mycobacteria from smear-negative specimens
    • Morgan, M. A., C. D. Horstmeier, D. R. DeYoung, and G. D. Roberts. 1983. Comparison of a radiometric method (BACTEC) and conventional culture media for recovery of mycobacteria from smear-negative specimens. J. Clin. Microbiol. 18:384-388.
    • (1983) J. Clin. Microbiol. , vol.18 , pp. 384-388
    • Morgan, M.A.1    Horstmeier, C.D.2    DeYoung, D.R.3    Roberts, G.D.4
  • 17
    • 0027160869 scopus 로고
    • Reliability of cord formation in BACTEC media for presumptive identification of mycobacteria
    • Morris, A. J., and B. Reller. 1993. Reliability of cord formation in BACTEC media for presumptive identification of mycobacteria. J. Clin. Microbiol. 31:2533-2534.
    • (1993) J. Clin. Microbiol. , vol.31 , pp. 2533-2534
    • Morris, A.J.1    Reller, B.2
  • 18
    • 0002836279 scopus 로고
    • Mycobacterium
    • P. R. Murray, E. J. Baron, M. A. Pfaller, F. C. Tenover, and R. H. Yolken (ed.), American Society for Microbiology, Washington, D.C.
    • Nolte, F. S., and B. Metchock. 1995. Mycobacterium, p. 400-437. In P. R. Murray, E. J. Baron, M. A. Pfaller, F. C. Tenover, and R. H. Yolken (ed.), Manual of clinical microbiology, 6th ed. American Society for Microbiology, Washington, D.C.
    • (1995) Manual of Clinical Microbiology, 6th Ed. , pp. 400-437
    • Nolte, F.S.1    Metchock, B.2
  • 19
    • 37949014042 scopus 로고
    • Distribution-free or nonparametric tests
    • M. J. Norusis (ed.), SPSS Inc., Chicago
    • Norusis, M. J. 1993. Distribution-free or nonparametric tests, p. 377-411. In M. J. Norusis (ed.), SPSS for Windows base system user's guide, release 6.0. SPSS Inc., Chicago.
    • (1993) SPSS for Windows Base System User's Guide, Release 6.0 , pp. 377-411
    • Norusis, M.J.1
  • 20
    • 0027081827 scopus 로고
    • Comparative evaluation of the MB-Check system for recovery of mycobacteria from clinical specimens
    • Piersimoni, C., V. Morbiducci, G. De Sio, and G. Scalise. 1992. Comparative evaluation of the MB-Check system for recovery of mycobacteria from clinical specimens. Eur. J. Clin. Microbiol. Infect. Dis. 11:1174-1177.
    • (1992) Eur. J. Clin. Microbiol. Infect. Dis. , vol.11 , pp. 1174-1177
    • Piersimoni, C.1    Morbiducci, V.2    De Sio, G.3    Scalise, G.4
  • 21
    • 0020591225 scopus 로고
    • Evaluation of the BACTEC radiometric method for recovery of mycobacteria and drug susceptibility testing of Mycobacterium tuberculosis from acid-fast smear-positive specimens
    • Roberts, G. D., N. L. Goodman, L. Heifets, H. W. Larsh, T. H. Lindner, J. K. McClatchy, M. R. McGinnis, S. H. Siddiqi, and P. Wright. 1983. Evaluation of the BACTEC radiometric method for recovery of mycobacteria and drug susceptibility testing of Mycobacterium tuberculosis from acid-fast smear-positive specimens. J. Clin. Microbiol. 18:689-696.
    • (1983) J. Clin. Microbiol. , vol.18 , pp. 689-696
    • Roberts, G.D.1    Goodman, N.L.2    Heifets, L.3    Larsh, H.W.4    Lindner, T.H.5    McClatchy, J.K.6    McGinnis, M.R.7    Siddiqi, S.H.8    Wright, P.9
  • 22
    • 0027435188 scopus 로고
    • Comparison of the Septi-Chek AFB and BACTEC systems and conventional culture for recovery of mycobacteria
    • Sewell, D. L., A. L. Rashad, W. J. Rourke, Jr., S. L. Poor, J. C. McCarthy, and M. A. Pfaller. 1993. Comparison of the Septi-Chek AFB and BACTEC systems and conventional culture for recovery of mycobacteria. J. Clin. Microbiol. 31:2689-2691.
    • (1993) J. Clin. Microbiol. , vol.31 , pp. 2689-2691
    • Sewell, D.L.1    Rashad, A.L.2    Rourke Jr., W.J.3    Poor, S.L.4    McCarthy, J.C.5    Pfaller, M.A.6
  • 24
    • 0028978283 scopus 로고
    • Comparison of the recovery rates for mycobacteria from BACTEC 12B Vials, Middlebrook 7H11-selective 7H11 biplates, and Lowenstein-Jensen slants in a public health mycobacteriology laboratory
    • Wilson, M. L., B. L. Stone, M. V. Hildred, and R. R. Reves. 1995. Comparison of the recovery rates for mycobacteria from BACTEC 12B Vials, Middlebrook 7H11-selective 7H11 biplates, and Lowenstein-Jensen slants in a public health mycobacteriology laboratory. J. Clin. Microbiol. 33:2516-2518.
    • (1995) J. Clin. Microbiol. , vol.33 , pp. 2516-2518
    • Wilson, M.L.1    Stone, B.L.2    Hildred, M.V.3    Reves, R.R.4
  • 25
    • 0028887921 scopus 로고
    • Mycobacterial testing in clinical laboratories that participate in the College of American Pathologists' mycobacteriology e survey: Results of a 1993 questionnaire
    • Woods, G. L., and F. G. Witebsky. 1995. Mycobacterial testing in clinical laboratories that participate in the College of American Pathologists' mycobacteriology E survey: results of a 1993 questionnaire. J. Clin. Microbiol. 33:407-412.
    • (1995) J. Clin. Microbiol. , vol.33 , pp. 407-412
    • Woods, G.L.1    Witebsky, F.G.2
  • 26
    • 0025326342 scopus 로고
    • Cord formation in BACTEC 7H12 medium for rapid, presumptive identification of Mycobacterium tuberculosis complex
    • Yagupsky, P. V., D. A. Kaminski, K. M. Palmer, and F. S. Nolte. 1990. Cord formation in BACTEC 7H12 medium for rapid, presumptive identification of Mycobacterium tuberculosis complex. J. Clin. Microbiol. 28:1451-1453.
    • (1990) J. Clin. Microbiol. , vol.28 , pp. 1451-1453
    • Yagupsky, P.V.1    Kaminski, D.A.2    Palmer, K.M.3    Nolte, F.S.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.