메뉴 건너뛰기




Volumn 41, Issue 7, 1997, Pages 818-823

Uptake of inhaled nitric oxide in acute lung injury

Author keywords

Alveolar ventilation; Inhalation; Nitric oxide; Uptake

Indexed keywords

NITRIC OXIDE;

EID: 0030833793     PISSN: 00015172     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.1399-6576.1997.tb04794.x     Document Type: Article
Times cited : (17)

References (21)
  • 1
    • 0019195506 scopus 로고
    • The obligatory role of endothelial cells in the relaxation of arterial smooth muscle by acetylcholine
    • Furchgott RF, Zawadzki JV. The obligatory role of endothelial cells in the relaxation of arterial smooth muscle by acetylcholine. Nature 1980: 288: 373-376.
    • (1980) Nature , vol.288 , pp. 373-376
    • Furchgott, R.F.1    Zawadzki, J.V.2
  • 2
    • 0023198721 scopus 로고
    • Nitric oxide release accounts for the biological activity of endothelium-derived relaxing factor
    • Palmer RMJ, Ferrige AG, Moncada S. Nitric oxide release accounts for the biological activity of endothelium-derived relaxing factor. Nature 1987: 295: 524-526.
    • (1987) Nature , vol.295 , pp. 524-526
    • Palmer, R.M.J.1    Ferrige, A.G.2    Moncada, S.3
  • 3
    • 0023505509 scopus 로고
    • Endothelium derived relaxing factor produced and released from artery and vein is nitric oxide
    • Ignarro L, Buga GM, Wood KS, Byrns RE, Chaduri G. Endothelium derived relaxing factor produced and released from artery and vein is nitric oxide. Proc Nat Acad Sci USA 1987: 84: 9265-9269.
    • (1987) Proc Nat Acad Sci USA , vol.84 , pp. 9265-9269
    • Ignarro, L.1    Buga, G.M.2    Wood, K.S.3    Byrns, R.E.4    Chaduri, G.5
  • 4
    • 0026495018 scopus 로고
    • Inhaled nitric oxide after mitral valve replacement in patients with chronic pulmonary artery hypertension
    • Girard C, Lehot J-J, Pannetier J-C, Filley S, Ffrench P, Estanove S. Inhaled nitric oxide after mitral valve replacement in patients with chronic pulmonary artery hypertension. Anesthesiology 1992: 77: 880-883.
    • (1992) Anesthesiology , vol.77 , pp. 880-883
    • Girard, C.1    Lehot, J.-J.2    Pannetier, J.-C.3    Filley, S.4    Ffrench, P.5    Estanove, S.6
  • 5
    • 0026611008 scopus 로고
    • Low-dose inhalational nitric oxide in persistent pulmonary hypertension of the newborn
    • Kinsella J, Neish S, Shaffer E, Asman S. Low-dose inhalational nitric oxide in persistent pulmonary hypertension of the newborn. Lancet 1992: 340: 819-820.
    • (1992) Lancet , vol.340 , pp. 819-820
    • Kinsella, J.1    Neish, S.2    Shaffer, E.3    Asman, S.4
  • 8
    • 0027724030 scopus 로고
    • Long-term inhalation with evaluated low doses of nitric oxide for selective improvement of oxygenation in patients with adult respiratory distress syndrome
    • Gerlach H, Pappert D, Lewandowski R, Roissant R, Falke KJ. Long-term inhalation with evaluated low doses of nitric oxide for selective improvement of oxygenation in patients with adult respiratory distress syndrome. Intensive Care Med 1993: 19: 443-449.
    • (1993) Intensive Care Med , vol.19 , pp. 443-449
    • Gerlach, H.1    Pappert, D.2    Lewandowski, R.3    Roissant, R.4    Falke, K.J.5
  • 9
    • 0027521546 scopus 로고
    • Selective pulmonary vasodilation by inhaled nitric oxide is due to hemaglobin inactivation
    • Rimar S, Gillis CN. Selective pulmonary vasodilation by inhaled nitric oxide is due to hemaglobin inactivation. Circulation 1993: 88: 2884-2887.
    • (1993) Circulation , vol.88 , pp. 2884-2887
    • Rimar, S.1    Gillis, C.N.2
  • 14
    • 0014087851 scopus 로고
    • Two cases of poisoning by contamination of nitrous oxides of nitrogen during anaesthesia
    • Glutton-Brock J. Two cases of poisoning by contamination of nitrous oxides of nitrogen during anaesthesia. Br J Anaesth 1967: 39: 388-392.
    • (1967) Br J Anaesth , vol.39 , pp. 388-392
    • Glutton-Brock, J.1
  • 16
    • 0027494122 scopus 로고
    • Evaluation of a new system for ventilatory administration of nitric oxide
    • Stenqvist O, Kjelltoft B, Lundin S. Evaluation of a new system for ventilatory administration of nitric oxide. Acta Anaesthesiol Scand 1993: 37: 687-691.
    • (1993) Acta Anaesthesiol Scand , vol.37 , pp. 687-691
    • Stenqvist, O.1    Kjelltoft, B.2    Lundin, S.3
  • 17
    • 0029918988 scopus 로고    scopus 로고
    • Safety aspects on delivery and monitoring of nitric oxide during mechanical ventilation
    • Nathorst Westfelt U, Lundin S, Stenqvist O. Safety aspects on delivery and monitoring of nitric oxide during mechanical ventilation. Acta Anaesthesiol Scand 1996: 40: 302-310.
    • (1996) Acta Anaesthesiol Scand , vol.40 , pp. 302-310
    • Nathorst Westfelt, U.1    Lundin, S.2    Stenqvist, O.3
  • 18
    • 0024579499 scopus 로고
    • A simultaneus single breath measurement of pulmonary diffusing capacity with nitric oxide and carbon monoxide
    • Borland CDR, Higenbottarn TW. A simultaneus single breath measurement of pulmonary diffusing capacity with nitric oxide and carbon monoxide. Eur Respir J 1989: 2: 56-63.
    • (1989) Eur Respir J , vol.2 , pp. 56-63
    • Borland, C.D.R.1    Higenbottarn, T.W.2
  • 20
    • 1842286350 scopus 로고
    • 2 in MIK- und MAK-konzentrationen bei der inhalation
    • 2 in MIK- und MAK-konzentrationen bei der inhalation. Straub-Reinhalt Luft 1970: 30: 380-381.
    • (1970) Straub-Reinhalt Luft , vol.30 , pp. 380-381
    • Wagner, H.M.1
  • 21
    • 0028123418 scopus 로고
    • Auto-inhalation of nitric oxide after endogenous synthesis in the nasopharynx
    • Gerlach H, Rossaint R, Pappert D, Knorr M, Falke K. Auto-inhalation of nitric oxide after endogenous synthesis in the nasopharynx. Lancet 1994: 343: 518-519.
    • (1994) Lancet , vol.343 , pp. 518-519
    • Gerlach, H.1    Rossaint, R.2    Pappert, D.3    Knorr, M.4    Falke, K.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.