메뉴 건너뛰기




Volumn 24, Issue 10, 1997, Pages 1643-1646

Suitability of laser stimulated TLD arrays as patient dose monitors in high dose x-ray imaging

Author keywords

Angiography; Dosimetry; Interventional radiology; Skin dose; Thermoluminescence

Indexed keywords

ANGIOGRAPHY; DIAGNOSIS; FLUORESCENT SCREENS; MAGNESIUM COMPOUNDS; PHOTOGRAPHIC FILMS; THERMOLUMINESCENCE; UNCERTAINTY ANALYSIS;

EID: 0030801755     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.597973     Document Type: Article
Times cited : (14)

References (16)
  • 2
    • 0028185452 scopus 로고
    • Potential biological effects following high x-ray dose interventional procedures
    • L. K. Wagner, P. J Eifel, and R. A. Geise, "Potential biological effects following high x-ray dose interventional procedures," J. Vasc. Intervent Radiol. 5, 71-84 (1994).
    • (1994) J. Vasc. Intervent Radiol. , vol.5 , pp. 71-84
    • Wagner, L.K.1    Eifel, P.J.2    Geise, R.A.3
  • 4
    • 0026027082 scopus 로고
    • Tissue doses in the upper gastrointestinal fluoroscopy examination
    • O. H Suleiman, J. Anderson, B. Jones, G. U. V. Rao, and M. Rosenstein, "Tissue doses in the upper gastrointestinal fluoroscopy examination," Radiology 178, 653-658 (1991)
    • (1991) Radiology , vol.178 , pp. 653-658
    • Suleiman, O.H.1    Anderson, J.2    Jones, B.3    Rao, G.U.V.4    Rosenstein, M.5
  • 5
    • 0029976850 scopus 로고    scopus 로고
    • Radiation doses during pediatric radiofrequency catheter ablation procedures
    • R. A. Geise, N. E. Peters, A. Dunnigan, and S. Milstein, "Radiation doses during pediatric radiofrequency catheter ablation procedures," PACE 19, 1605-1611 (1996).
    • (1996) PACE , vol.19 , pp. 1605-1611
    • Geise, R.A.1    Peters, N.E.2    Dunnigan, A.3    Milstein, S.4
  • 6
    • 0030926810 scopus 로고    scopus 로고
    • Evaluation of an on-line patient exposure meter in neuroradiology
    • N A Gkanatsios, W. Huda, K. R. Peters, and J. A. Freeman, "Evaluation of an on-line patient exposure meter in neuroradiology," Radiology 203, 837-842 (1997)
    • (1997) Radiology , vol.203 , pp. 837-842
    • Gkanatsios, N.A.1    Huda, W.2    Peters, K.R.3    Freeman, J.A.4
  • 7
    • 0006194438 scopus 로고
    • Comparison of two patient exposure measuring devices in a busy cardiac catheterization laboratory
    • M. V. Pina and J. A. Deye, "Comparison of two patient exposure measuring devices in a busy cardiac catheterization laboratory," Med. Phys. 20, 917 (1993).
    • (1993) Med. Phys. , vol.20 , pp. 917
    • Pina, M.V.1    Deye, J.A.2
  • 8
    • 0343098868 scopus 로고
    • A photographic method of measuring fluoroscopic dose to the patient
    • H. Blatz and E. R. Epp, "A photographic method of measuring fluoroscopic dose to the patient," Radiology 76, 120-121 (1961).
    • (1961) Radiology , vol.76 , pp. 120-121
    • Blatz, H.1    Epp, E.R.2
  • 9
    • 0025061472 scopus 로고
    • Radiotherapy verification film for estimating cumulative entrance exposure for fluoroscopic examinations
    • R. A. Geise and H. J. Ansel, "Radiotherapy verification film for estimating cumulative entrance exposure for fluoroscopic examinations," Health Phys 59, 295-298 (1990).
    • (1990) Health Phys , vol.59 , pp. 295-298
    • Geise, R.A.1    Ansel, H.J.2
  • 10
    • 0343534782 scopus 로고
    • A method for estimating the average bone marrow dose from some fluoroscopic examinations
    • A. Liuzzi, H. Blatz, and M A. Eisenbud, "A method for estimating the average bone marrow dose from some fluoroscopic examinations," Radiology 82, 99-105 (1964).
    • (1964) Radiology , vol.82 , pp. 99-105
    • Liuzzi, A.1    Blatz, H.2    Eisenbud, M.A.3
  • 11
    • 0015255977 scopus 로고
    • Exposure pattern, surface, bone marrow, integral and gonadal dose from fluoroscopy
    • K. Takeshita, S. Antoku, and S Sawada, "Exposure pattern, surface, bone marrow, integral and gonadal dose from fluoroscopy," Br. J. Radiol. 45, 53-58 (1972).
    • (1972) Br. J. Radiol. , vol.45 , pp. 53-58
    • Takeshita, K.1    Antoku, S.2    Sawada, S.3
  • 12
    • 0014082834 scopus 로고
    • Estimation of exposure pattern and bone marrow and gonadal doses during fluoroscopy
    • H Yoshinaga, K. Takeshita, S. Sawada, V. W. Russel, and S. Antoku, "Estimation of exposure pattern and bone marrow and gonadal doses during fluoroscopy," Br. J. Radiol. 40, 344-349 (1967).
    • (1967) Br. J. Radiol. , vol.40 , pp. 344-349
    • Yoshinaga, H.1    Takeshita, K.2    Sawada, S.3    Russel, V.W.4    Antoku, S.5
  • 13
    • 0028963623 scopus 로고
    • A survey of films for use as dosimeters in interventional radiology
    • L. F. Fajardo, R. A Geise, and E. R. Ritenour, "A survey of films for use as dosimeters in interventional radiology," Health Phys. 68, 595-599 (1995).
    • (1995) Health Phys. , vol.68 , pp. 595-599
    • Fajardo, L.F.1    Geise, R.A.2    Ritenour, E.R.3
  • 14
    • 0006157657 scopus 로고
    • Laser heated thermoluminescence dosimetry
    • edited by R. P. Rao Nova Science, Cormack, NY
    • P. F. Braunlich, "Laser heated thermoluminescence dosimetry" in Luminescence: Phenomena, Materials, and Devices, edited by R. P. Rao (Nova Science, Cormack, NY, 1992).
    • (1992) Luminescence: Phenomena, Materials, and Devices
    • Braunlich, P.F.1
  • 15
    • 0030758737 scopus 로고    scopus 로고
    • Temperature response of two photographic films and TLDs suitable for patient dosimetry of high dose fluoroscopic procedures
    • W. Lien and R. A Geise, "Temperature response of two photographic films and TLDs suitable for patient dosimetry of high dose fluoroscopic procedures," Health Phys. 73, 483-487 (1997)
    • (1997) Health Phys. , vol.73 , pp. 483-487
    • Lien, W.1    Geise, R.A.2
  • 16
    • 0019965153 scopus 로고
    • 2) during diagnostic radiology examinations
    • 2) during diagnostic radiology examinations," Phys. Med. Biol. 27, 871-878 (1982).
    • (1982) Phys. Med. Biol. , vol.27 , pp. 871-878
    • Shrimpton, P.C.1    Wall, B.F.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.