메뉴 건너뛰기




Volumn 203, Issue 3, 1997, Pages 837-842

Evaluation of an on-line patient exposure meter in neuroradiology

Author keywords

Interventional procedures; Radiations, exposure to patients and personnel; Radiations, measurement

Indexed keywords

ARTICLE; CLINICAL PROTOCOL; CONTROLLED STUDY; DIGITAL RADIOGRAPHY; DOSIMETRY; FLUOROSCOPY; HUMAN; IONIZATION CHAMBER; MAJOR CLINICAL STUDY; NEURORADIOLOGY; ONLINE SYSTEM; PRIORITY JOURNAL; RADIATION EXPOSURE; RADIATION MONITORING; SKIN;

EID: 0030926810     PISSN: 00338419     EISSN: None     Source Type: Journal    
DOI: 10.1148/radiology.203.3.9169713     Document Type: Article
Times cited : (40)

References (22)
  • 1
    • 0027960590 scopus 로고
    • Radiation-induced temporary epilation after a neuroradiologically guided embolization procedure
    • Huda W, Peters KR. Radiation-induced temporary epilation after a neuroradiologically guided embolization procedure. Radiology 1994; 193:642-644.
    • (1994) Radiology , vol.193 , pp. 642-644
    • Huda, W.1    Peters, K.R.2
  • 2
    • 0030228293 scopus 로고    scopus 로고
    • Radiation-induced skin injuries from fluoroscopy
    • Shope TB. Radiation-induced skin injuries from fluoroscopy. RadioGraphics 1996; 16:1195-1199.
    • (1996) RadioGraphics , vol.16 , pp. 1195-1199
    • Shope, T.B.1
  • 3
    • 0004551098 scopus 로고
    • The use of filters to control radiation exposure to the patient in diagnostic roentgenology
    • Trout D, Kelley J, Cathey G. The use of filters to control radiation exposure to the patient in diagnostic roentgenology. AJR 1952; 57:946-963.
    • (1952) AJR , vol.57 , pp. 946-963
    • Trout, D.1    Kelley, J.2    Cathey, G.3
  • 4
    • 0022595654 scopus 로고
    • Filter materials for dose reduction in screen-film radiography
    • Koedooder K, Venema HW. Filter materials for dose reduction in screen-film radiography. Phys Med Biol 1986; 31:585-600.
    • (1986) Phys Med Biol , vol.31 , pp. 585-600
    • Koedooder, K.1    Venema, H.W.2
  • 5
    • 0344591201 scopus 로고
    • Non-hardening x-ray beam attenuating filters
    • Rudin S, Bednarek DR. Non-hardening x-ray beam attenuating filters (abstr). Med Phys 1993; 20:918.
    • (1993) Med Phys , vol.20 , pp. 918
    • Rudin, S.1    Bednarek, D.R.2
  • 6
    • 0003631737 scopus 로고
    • Publication 34. Oxford, England: Pergamon Press
    • International Commission on Radiological Protection (ICRP). Protection of the patient in diagnostic radiology. Publication 34. Oxford, England: Pergamon Press, 1982.
    • (1982) Protection of the Patient in Diagnostic Radiology
  • 7
    • 0028185452 scopus 로고
    • Potential biological effects following high x-ray dose interventional procedures
    • Wagner LK, Eifel PJ, Geise RA. Potential biological effects following high x-ray dose interventional procedures. JVIR 1994; 5: 71-84.
    • (1994) JVIR , vol.5 , pp. 71-84
    • Wagner, L.K.1    Eifel, P.J.2    Geise, R.A.3
  • 8
    • 0019965153 scopus 로고
    • 2) during diagnostic radiological examinations
    • 2) during diagnostic radiological examinations. Phys Med Biol 1982; 27:871-878.
    • (1982) Phys Med Biol , vol.27 , pp. 871-878
    • Shrimpton, P.1    Wall, B.2
  • 13
    • 0021131849 scopus 로고
    • Backscatter factors for x-rays generated at voltages between 10 and 100 kV
    • Grosswendt B. Backscatter factors for x-rays generated at voltages between 10 and 100 kV. Phys Med Biol 1984; 29:579-591.
    • (1984) Phys Med Biol , vol.29 , pp. 579-591
    • Grosswendt, B.1
  • 14
    • 0024355954 scopus 로고
    • Experimentally determined backscatter factors for x-rays generated at voltages between 16 and 140 kV
    • Klevenhagen SC. Experimentally determined backscatter factors for x-rays generated at voltages between 16 and 140 kV. Phys Med Biol 1989; 34:1871-1882.
    • (1989) Phys Med Biol , vol.34 , pp. 1871-1882
    • Klevenhagen, S.C.1
  • 17
    • 0003555624 scopus 로고
    • New York, NY: United Nations
    • United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR). Sources, effects and risks of ionizing radiation. New York, NY: United Nations, 1988.
    • (1988) Sources, Effects and Risks of Ionizing Radiation
  • 18
    • 0024413015 scopus 로고
    • Comparison of performance characteristics of conventional and K-edge filters in general diagnostic radiology
    • Nagel DH. Comparison of performance characteristics of conventional and K-edge filters in general diagnostic radiology. Phys Med Biol 1989; 34:1269-1287.
    • (1989) Phys Med Biol , vol.34 , pp. 1269-1287
    • Nagel, D.H.1
  • 19
    • 0028605949 scopus 로고
    • Perception of fluoroscopy last image hold
    • Wilson DL, Xue P, Aufrichtig R. Perception of fluoroscopy last image hold. Med Phys 1994; 21:1875-1883.
    • (1994) Med Phys , vol.21 , pp. 1875-1883
    • Wilson, D.L.1    Xue, P.2    Aufrichtig, R.3
  • 20
    • 0026638303 scopus 로고
    • Effective dose equivalents to patients undergoing cerebral angiography
    • Feygelman M, Huda W, Peters KR. Effective dose equivalents to patients undergoing cerebral angiography. AJNR 1992; 13: 845-849.
    • (1992) AJNR , vol.13 , pp. 845-849
    • Feygelman, M.1    Huda, W.2    Peters, K.R.3
  • 21
    • 0026712220 scopus 로고
    • Estimation of effective dose to the patient during medical x-ray examinations from measurements of the dose-area products
    • Le Heron J. Estimation of effective dose to the patient during medical x-ray examinations from measurements of the dose-area products. Phys Med Biol 1992; 37:2117-2126.
    • (1992) Phys Med Biol , vol.37 , pp. 2117-2126
    • Le Heron, J.1
  • 22
    • 0025221903 scopus 로고
    • E, in diagnostic radiology
    • E, in diagnostic radiology. Med Phys 1990; 17:998-1003.
    • (1990) Med Phys , vol.17 , pp. 998-1003
    • Huda, W.1    Bissessur, K.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.