메뉴 건너뛰기




Volumn 24, Issue 8, 1997, Pages 1229-1234

A method for more efficient source localization of interstitial implants with biplane radiographs

Author keywords

Interstitial implant; Source localization

Indexed keywords

LOCATION;

EID: 0030800196     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.598145     Document Type: Article
Times cited : (5)

References (16)
  • 1
    • 0019471638 scopus 로고
    • A three-film technique for reconstruction radioactive seed implants
    • H. I. Amols and I. I. Rosen, "A three-film technique for reconstruction radioactive seed implants," Med. Phys. 8, 210-214 (1981).
    • (1981) Med. Phys. , vol.8 , pp. 210-214
    • Amols, H.I.1    Rosen, I.I.2
  • 2
    • 0020576692 scopus 로고
    • An automatic method for localizing radioactive seeds in implant dosimetry
    • D. D. Jackson, "An automatic method for localizing radioactive seeds in implant dosimetry," Med. Phys. 10, 370-372 (1983).
    • (1983) Med. Phys. , vol.10 , pp. 370-372
    • Jackson, D.D.1
  • 3
    • 0020565327 scopus 로고
    • Geometric reconstruction of seed implants using a three-film technique
    • P. J. Biggs and D. M. Kelly, "Geometric reconstruction of seed implants using a three-film technique," Med. Phys. 10, 701-704 (1983).
    • (1983) Med. Phys. , vol.10 , pp. 701-704
    • Biggs, P.J.1    Kelly, D.M.2
  • 4
    • 0020578574 scopus 로고
    • An automatic seed identification technique for interstitial using three isocentric radiographs
    • M. S. Rosenthal and R. Nath, "An automatic seed identification technique for interstitial using three isocentric radiographs," Med. Phys. 10, 475-479 (1983).
    • (1983) Med. Phys. , vol.10 , pp. 475-479
    • Rosenthal, M.S.1    Nath, R.2
  • 5
    • 0028834204 scopus 로고
    • Source localization for implants with particular reference to stepping-source afterloaders
    • K. A. Weaver, B. Pickett, L. W. Robberts, and A. Stuart, "Source localization for implants with particular reference to stepping-source afterloaders," Med. Phys. 22, 83-88 (1995).
    • (1995) Med. Phys. , vol.22 , pp. 83-88
    • Weaver, K.A.1    Pickett, B.2    Robberts, L.W.3    Stuart, A.4
  • 6
    • 0016608373 scopus 로고
    • Automatic localization of curved wires used in brachytherapy: The COUREP program
    • J. C. Rosenwald, "Automatic localization of curved wires used in brachytherapy: The COUREP program," Comput. Prog. Biomed. 4, 103-112 (1975).
    • (1975) Comput. Prog. Biomed. , vol.4 , pp. 103-112
    • Rosenwald, J.C.1
  • 7
    • 0021034958 scopus 로고
    • Rapid, accurate, three-dimensional location of multiple seeds in implant radiotherapy treatment planning
    • D. Altschuler, P. A. Findlay, and R. D. Epperson, "Rapid, accurate, three-dimensional location of multiple seeds in implant radiotherapy treatment planning," Phys. Med. Biol. 28, 1305-1318 (1983).
    • (1983) Phys. Med. Biol. , vol.28 , pp. 1305-1318
    • Altschuler, D.1    Findlay, P.A.2    Epperson, R.D.3
  • 8
    • 0021748496 scopus 로고
    • A general approach to the location of radio-opaque objects with applications to radiotherapy
    • D. A. Christopherson and D. Jones, "A general approach to the location of radio-opaque objects with applications to radiotherapy," Phys. Med. Biol. 29, 1581-1586 (1984).
    • (1984) Phys. Med. Biol. , vol.29 , pp. 1581-1586
    • Christopherson, D.A.1    Jones, D.2
  • 9
    • 0022005429 scopus 로고
    • Two-film brachytherapy reconstruction algorithm
    • R. L. Siddon and L. M. Chin, "Two-film brachytherapy reconstruction algorithm," Med. Phys. 12, 77-83 (1984).
    • (1984) Med. Phys. , vol.12 , pp. 77-83
    • Siddon, R.L.1    Chin, L.M.2
  • 10
    • 0024593020 scopus 로고
    • Determination of three-dimensional structure in biplane radiography without knowledge of the relationship between the two views: Theory
    • C. E. Metz and L. E. Fencil, "Determination of three-dimensional structure in biplane radiography without knowledge of the relationship between the two views: Theory," Med. Phys. 16, 45-51 (1989).
    • (1989) Med. Phys. , vol.16 , pp. 45-51
    • Metz, C.E.1    Fencil, L.E.2
  • 12
    • 0028226185 scopus 로고
    • Semiautomated matching and seed position localization for implanted ribbons
    • A. Kassaee and M. D. Altschuler, "Semiautomated matching and seed position localization for implanted ribbons," Med. Phys. 21, 643-650 (1994).
    • (1994) Med. Phys. , vol.21 , pp. 643-650
    • Kassaee, A.1    Altschuler, M.D.2
  • 13
    • 0029895538 scopus 로고    scopus 로고
    • A new source localization algorithm with no requirement of one-to-one source correspondence between biplane radiographs
    • S. Li, G. T. Y. Chen, C. A. Pelizzari, C. Reft, J. C. Roeske, and Y. Lu, "A new source localization algorithm with no requirement of one-to-one source correspondence between biplane radiographs," Med. Phys. 23, 921-927 (1996).
    • (1996) Med. Phys. , vol.23 , pp. 921-927
    • Li, S.1    Chen, G.T.Y.2    Pelizzari, C.A.3    Reft, C.4    Roeske, J.C.5    Lu, Y.6
  • 15
    • 0001008029 scopus 로고
    • An efficient method for finding the minimum of a function of several variables without calculating derivatives
    • M. J. D. Powell, "An efficient method for finding the minimum of a function of several variables without calculating derivatives," Comput J. 7, 155-163 (1964).
    • (1964) Comput J. , vol.7 , pp. 155-163
    • Powell, M.J.D.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.