Volumn 23, Issue 6, 1996, Pages 921-927

A new source localization algorithm with no requirement of one-to-one source correspondence between biplane radiographs

Author keywords

analytic solution; back projection; biplane radiographs; locus reconstruction; one to one source correspondence; source localization

Indexed keywords

EFFICIENCY;

EID: 0029895538     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.597734     Document Type: Article
Times cited : (21)

References (13)
  • 1
    • 0021748496 scopus 로고
    • A general approach to the location of radio-opaque objects with applications to radiotherapy
    • D A. Christopherson and D. Jones, "A general approach to the location of radio-opaque objects with applications to radiotherapy," Phys. Med. Biol. 29, 1581-1586 (1984).
    • (1984) Phys. Med. Biol. , vol.29 , pp. 1581-1586
    • Christopherson, D.A.1    Jones, D.2
  • 2
    • 0016608373 scopus 로고
    • Automatic localization of curved wires used in brachytherapy: The COUREP program
    • J. C. Rosenwald, "Automatic localization of curved wires used in brachytherapy: The COUREP program," Comput. Prog. Biomed. 4, 103-112 (1975).
    • (1975) Comput. Prog. Biomed. , vol.4 , pp. 103-112
    • Rosenwald, J.C.1
  • 3
    • 0028226185 scopus 로고
    • Semiautomated matching and seed position localization for implanted ribbons
    • A. Kassaee and M. D. Altschuler, "Semiautomated matching and seed position localization for implanted ribbons," Med. Phys. 21, 643-650 (1994).
    • (1994) Med. Phys. , vol.21 , pp. 643-650
    • Kassaee, A.1    Altschuler, M.D.2
  • 4
    • 0027965103 scopus 로고
    • Computer-aided geometric reconstruction of Fletcher-Suit source positions
    • S. Li, C. A. Pelizzari, C. Reft, H. G. Sutton, and G. T. Y. Chen, "Computer-aided geometric reconstruction of Fletcher-Suit source positions," Med. Phys. 21, 1123-1130 (1994).
    • (1994) Med. Phys. , vol.21 , pp. 1123-1130
    • Li, S.1    Pelizzari, C.A.2    Reft, C.3    Sutton, H.G.4    Chen, G.T.Y.5
  • 5
    • 0028834204 scopus 로고
    • Source localization for implants with particular reference to stepping-source afterloaders
    • K. A. Weaver, B. Pickett, L. W. Robberts, and A. Stuart, "Source localization for implants with particular reference to stepping-source afterloaders," Med. Phys. 22, 83-88 (1995).
    • (1995) Med. Phys. , vol.22 , pp. 83-88
    • Weaver, K.A.1    Pickett, B.2    Robberts, L.W.3    Stuart, A.4
  • 6
    • 0021034958 scopus 로고
    • Rapid, accurate, three-dimensional location of multiple seeds in implant radiotherapy treatment planning
    • M. D. Altschuler, P. A. Findlay, and R. D. Epperson, "Rapid, accurate, three-dimensional location of multiple seeds in implant radiotherapy treatment planning," Phys. Med. Biol. 28, 1305-1318 (1983).
    • (1983) Phys. Med. Biol. , vol.28 , pp. 1305-1318
    • Altschuler, M.D.1    Findlay, P.A.2    Epperson, R.D.3
  • 9
    • 0024593020 scopus 로고
    • Determination of three-dimensional structure in biplane radiography without knowledge of the relationship between the two views: Theory
    • C E. Metz and L. E. Pencil, "Determination of three-dimensional structure in biplane radiography without knowledge of the relationship between the two views: Theory," Med. Phys. 16, 45-51 (1989).
    • (1989) Med. Phys. , vol.16 , pp. 45-51
    • Metz, C.E.1    Pencil, L.E.2
  • 10
    • 0019471638 scopus 로고
    • A three-film technique for reconstruction radioactive seed implants
    • H. I. Amols and I. I. Rosen, "A three-film technique for reconstruction radioactive seed implants," Med. Phys. 8, 210-214 (1981).
    • (1981) Med. Phys. , vol.8 , pp. 210-214
    • Amols, H.I.1    Rosen, I.I.2
  • 11
    • 0022005429 scopus 로고
    • Two-film brachytherapy reconstruction algorithm
    • R. L. Siddon and L. M. Chin, "Two-film brachytherapy reconstruction algorithm," Med. Phys. 12, 77-83 (1984).
    • (1984) Med. Phys. , vol.12 , pp. 77-83
    • Siddon, R.L.1    Chin, L.M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.