메뉴 건너뛰기




Volumn 89, Issue 1, 1997, Pages 25-28

A prospective randomized comparison between fixed rate response programming and automatic rate response optimization in activity-triggered DDDR pacemakers

Author keywords

Activity rate response; Automatic rate response adjustment; DDDR pacemaker activity triggered; Pacing percentage of; Rate response optimization

Indexed keywords

ADULT; AGED; ARTICLE; ARTIFICIAL HEART PACEMAKER; CLINICAL ARTICLE; CLINICAL TRIAL; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; DAILY LIFE ACTIVITY; EXERCISE; FEMALE; FOLLOW UP; HEART ARRHYTHMIA; HEART ATRIUM PACING; HEART PACING; HEART PALPITATION; HEART VENTRICLE PACING; HOSPITAL DISCHARGE; HUMAN; INTERMETHOD COMPARISON; MALE; PRIORITY JOURNAL; RANDOMIZED CONTROLLED TRIAL; TREATMENT OUTCOME; MIDDLE AGED; PROSPECTIVE STUDY;

EID: 0030781959     PISSN: 00086312     EISSN: None     Source Type: Journal    
DOI: 10.1159/000006739     Document Type: Article
Times cited : (4)

References (13)
  • 1
    • 0025563382 scopus 로고
    • Rate-modulated pacing
    • Furman S: Rate-modulated pacing. Circulation 1990;82:1081-1094.
    • (1990) Circulation , vol.82 , pp. 1081-1094
    • Furman, S.1
  • 2
    • 0026077889 scopus 로고
    • Effects of body constitution and age on maximum pacing rate of activity-modulated rate response pacemakers
    • Schuchert A, Kuck K-H, Bleifeld W: Effects of body constitution and age on maximum pacing rate of activity-modulated rate response pacemakers. PACE 1991;14:1467-1472.
    • (1991) PACE , vol.14 , pp. 1467-1472
    • Schuchert, A.1    Kuck, K.-H.2    Bleifeld, W.3
  • 3
    • 0026341017 scopus 로고
    • One year's follow-up of automatic adaptation of the rate response algorithm of the QT sensing, rate adaptive pacemaker
    • Baig MW, Boute W, Begemann M, Perrins EJ: One year's follow-up of automatic adaptation of the rate response algorithm of the QT sensing, rate adaptive pacemaker. PACE 1991;14: 1598-1605.
    • (1991) PACE , vol.14 , pp. 1598-1605
    • Baig, M.W.1    Boute, W.2    Begemann, M.3    Perrins, E.J.4
  • 4
    • 9844232263 scopus 로고
    • Automatic optimization of the slope of a new accelerometer controlled VVIR pacemaker
    • Werner K, Geroux L, Ripart A: Automatic optimization of the slope of a new accelerometer controlled VVIR pacemaker (abstract). PACE 1995;18:1775.
    • (1995) PACE , vol.18 , pp. 1775
    • Werner, K.1    Geroux, L.2    Ripart, A.3
  • 5
    • 9844265944 scopus 로고
    • An automatic calibration function can provide optimal rate-modulated slope
    • Razzani M, the investigators of the auto-calibration function evaluation of the Chorus RM pacemaker: An automatic calibration function can provide optimal rate-modulated slope (abstract). PACE 1995;18:1782.
    • (1995) PACE , vol.18 , pp. 1782
    • Razzani, M.1
  • 6
    • 0029957179 scopus 로고    scopus 로고
    • Automatic sensor adjustment in a rate-modulated pacemaker
    • Gentzler R, the Trilogy DR+ phase 1 clinical investigators, Lucas EH: Automatic sensor adjustment in a rate-modulated pacemaker. PACE 1996;19:661.
    • (1996) PACE , vol.19 , pp. 661
    • Gentzler, R.1    Lucas, E.H.2
  • 7
    • 0024598481 scopus 로고
    • Comparison of exercise performance of six rate-adaptive right ventricular cardiac pacemakers
    • Lau C-P, Butrous GS, Ward DE, Camm AJ: Comparison of exercise performance of six rate-adaptive right ventricular cardiac pacemakers. Am J Cardiol 1989;63:833-838.
    • (1989) Am J Cardiol , vol.63 , pp. 833-838
    • Lau, C.-P.1    Butrous, G.S.2    Ward, D.E.3    Camm, A.J.4
  • 8
    • 0009631865 scopus 로고
    • Limitations of rate response of an activity-sensing rate-responsive pacemaker to different forms of activity
    • Lau C-P, Metha D, Toff WD, Stott RJ, Ward DE, Camm AJ: Limitations of rate response of an activity-sensing rate-responsive pacemaker to different forms of activity. PACE 1988;11: 141-150.
    • (1988) PACE , vol.11 , pp. 141-150
    • Lau, C.-P.1    Metha, D.2    Toff, W.D.3    Stott, R.J.4    Ward, D.E.5    Camm, A.J.6
  • 9
    • 0026532330 scopus 로고
    • Activity-based pacing: Comparison of a device using an accelerometer versus a piezoelectric crystal
    • Bacharach DW, Hilden TS, Millerhagen JO, Estrum BL, Kelly JM: Activity-based pacing: Comparison of a device using an accelerometer versus a piezoelectric crystal. PACE 1992;15: 188-196.
    • (1992) PACE , vol.15 , pp. 188-196
    • Bacharach, D.W.1    Hilden, T.S.2    Millerhagen, J.O.3    Estrum, B.L.4    Kelly, J.M.5
  • 11
    • 0024242945 scopus 로고
    • Rate response during submaximal exercise: Comparison of three different sensors
    • Zegelman M, Cieslinski G, Kreuzer L: Rate response during submaximal exercise: Comparison of three different sensors. PACE 1988; 11:1888-1895.
    • (1988) PACE , vol.11 , pp. 1888-1895
    • Zegelman, M.1    Cieslinski, G.2    Kreuzer, L.3
  • 13
    • 0025038262 scopus 로고
    • Is accurate rate response programming necessary?
    • Sulke N, Dritsas A, Chambers J, Sowton E: Is accurate rate response programming necessary? PACE 1990;13:1031-1044.
    • (1990) PACE , vol.13 , pp. 1031-1044
    • Sulke, N.1    Dritsas, A.2    Chambers, J.3    Sowton, E.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.