메뉴 건너뛰기




Volumn 78, Issue 3 A, 1996, Pages 4-7

The state of the stent: Current practices, controversies, and future trends

Author keywords

[No Author keywords available]

Indexed keywords

ACETYLSALICYLIC ACID; ANGIOPEPTIN; ANTICOAGULANT AGENT; ANTITHROMBOCYTIC AGENT; CLOPIDOGREL; FIBRINOGEN RECEPTOR ANTAGONIST; HEPARIN; NITRIC OXIDE; PHOSPHORYLCHOLINE; TICLOPIDINE; TRAPIDIL;

EID: 0029821777     PISSN: 00029149     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0002-9149(96)00485-7     Document Type: Conference Paper
Times cited : (18)

References (11)
  • 1
    • 0011313357 scopus 로고
    • Genetically engineered endothelial cells: Increased surface fibrinolysis and potential adaptation to endovascular stenting
    • Sawa H, Vinogradsky B, Guala A, Fujii S. Genetically engineered endothelial cells: increased surface fibrinolysis and potential adaptation to endovascular stenting. Circulation 1995;92(suppl I):I536.
    • (1995) Circulation , vol.92 , Issue.SUPPL. I
    • Sawa, H.1    Vinogradsky, B.2    Guala, A.3    Fujii, S.4
  • 2
    • 0029004856 scopus 로고
    • Endovascular stent design dictates experimental restenosis and thrombosis
    • Rogers C, Edelman ER. Endovascular stent design dictates experimental restenosis and thrombosis. Circulation 1995;91:2995-3001.
    • (1995) Circulation , vol.91 , pp. 2995-3001
    • Rogers, C.1    Edelman, E.R.2
  • 3
    • 0010647778 scopus 로고
    • Stenting of the right coronary artery for de novo stenosis. A comparison of the Wiktor and the Palmaz-Schatz stents
    • Goy JJ, Eeckhout E, Debbas N, Stauffer JC, Vogt P. Stenting of the right coronary artery for de novo stenosis. A comparison of the Wiktor and the Palmaz-Schatz stents. Circulation 1995;92(suppl I):I596.
    • (1995) Circulation , vol.92 , Issue.SUPPL. I
    • Goy, J.J.1    Eeckhout, E.2    Debbas, N.3    Stauffer, J.C.4    Vogt, P.5
  • 4
    • 0028087616 scopus 로고
    • Caveats about elective coronary stenting
    • Topol EJ. Caveats about elective coronary stenting. (Editorial.) N Engl J Med 1994;331:539-541.
    • (1994) N Engl J Med , vol.331 , pp. 539-541
    • Topol, E.J.1
  • 5
    • 4243644335 scopus 로고
    • Five year clinical and angiographic follow-up of the coronary Wallstent
    • Carrié D, Keane D, Elbaz M, Serruys PW, Puel J. Five year clinical and angiographic follow-up of the coronary Wallstent. Circulation 1995;92(suppl I):I409.
    • (1995) Circulation , vol.92 , Issue.SUPPL. I
    • Carrié, D.1    Keane, D.2    Elbaz, M.3    Serruys, P.W.4    Puel, J.5
  • 6
    • 0342821678 scopus 로고
    • Late clinical follow-up 9 years after intracoronary stenting with the Wallstent
    • Debbas N, Sigwart U, Eeckhout E, Stauffer JC, Vogt P, Goy JJ. Late clinical follow-up 9 years after intracoronary stenting with the Wallstent. Circulation 1995;92(suppl I):I280.
    • (1995) Circulation , vol.92 , Issue.SUPPL. I
    • Debbas, N.1    Sigwart, U.2    Eeckhout, E.3    Stauffer, J.C.4    Vogt, P.5    Goy, J.J.6
  • 7
    • 0028967898 scopus 로고
    • Late lumen loss after coronary angioplasty is associated with the activation status of circulating phagocytes before treatment
    • Pietersma A, Kofflard M, de Wit LEA, Stijnen T, Koster JH, Serruys PW, Sluiter W. Late lumen loss after coronary angioplasty is associated with the activation status of circulating phagocytes before treatment. Circulation 1995;91:1320-1325.
    • (1995) Circulation , vol.91 , pp. 1320-1325
    • Pietersma, A.1    Kofflard, M.2    De Wit, L.E.A.3    Stijnen, T.4    Koster, J.H.5    Serruys, P.W.6    Sluiter, W.7
  • 8
    • 4243644332 scopus 로고
    • Doppler guide wire as a primary guide wire for PTCA. Feasibility, safety and continuous monitoring of the results
    • DEBATE Study Group. Doppler guide wire as a primary guide wire for PTCA. Feasibility, safety and continuous monitoring of the results. Circulation 1995;92(suppl I):I263.
    • (1995) Circulation , vol.92 , Issue.SUPPL. I


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.