메뉴 건너뛰기




Volumn 11, Issue 5, 1996, Pages 629-636

An analysis of a retrieved prodigy femoral prosthesis

Author keywords

femoral prosthesis; hip arthroplasty

Indexed keywords

AGED; ARTICLE; AUTOPSY; BONE ATROPHY; BONE GROWTH; CASE REPORT; FEMUR; HUMAN; HUMAN TISSUE; MALE; TOTAL HIP PROSTHESIS;

EID: 0029810002     PISSN: 08835403     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0883-5403(96)80122-7     Document Type: Article
Times cited : (2)

References (10)
  • 1
    • 0023415324 scopus 로고
    • The effect of proximally and fully porous-coated canine hip stem design on bone modeling
    • Bobyn JD, Pilliar RM, Binnington AG, Szivek JA: The effect of proximally and fully porous-coated canine hip stem design on bone modeling. J Orthop Res 5:393, 1987
    • (1987) J Orthop Res , vol.5 , pp. 393
    • Bobyn, J.D.1    Pilliar, R.M.2    Binnington, A.G.3    Szivek, J.A.4
  • 2
    • 0023946442 scopus 로고
    • The uncemented porous-coated anatomic total hip prosthesis: Two-year results of a prospective consecutive series
    • Callaghan JJ, Dysart SH, Savory CG: The uncemented porous-coated anatomic total hip prosthesis: two-year results of a prospective consecutive series. J Bone Joint Surg 70A:337, 1988
    • (1988) J Bone Joint Surg , vol.70 A , pp. 337
    • Callaghan, J.J.1    Dysart, S.H.2    Savory, C.G.3
  • 3
    • 0023777583 scopus 로고
    • The influence of stem size and extent of porous coating on femoral bone resorption after primary cementless hip arthroplasty
    • Engh CA, Bobyn JD: The influence of stem size and extent of porous coating on femoral bone resorption after primary cementless hip arthroplasty. Clin Orthop 231:7, 1988
    • (1988) Clin Orthop , vol.231 , pp. 7
    • Engh, C.A.1    Bobyn, J.D.2
  • 4
    • 0025179416 scopus 로고
    • Roentgenographic assessment of the biologic fixation of porous-surfaced femoral components
    • Erratum: Clin Orthop 284:310, 1992
    • Engh CA, Massin P, Suthers KE: Roentgenographic assessment of the biologic fixation of porous-surfaced femoral components. Clin Orthop 231:107, 1990; Erratum: Clin Orthop 284:310, 1992
    • (1990) Clin Orthop , vol.231 , pp. 107
    • Engh, C.A.1    Massin, P.2    Suthers, K.E.3
  • 5
    • 0024461204 scopus 로고
    • Adaptive bone remodeling and biomechanical design considerations for noncemented total hip arthroplasty
    • Huiskes R, Weinans H, Dalstra M: Adaptive bone remodeling and biomechanical design considerations for noncemented total hip arthroplasty. Orthopedics 12:1255, 1989
    • (1989) Orthopedics , vol.12 , pp. 1255
    • Huiskes, R.1    Weinans, H.2    Dalstra, M.3
  • 6
    • 0020559913 scopus 로고
    • The madreporic cementless total hip arthroplasty: New experimental data and a seven-year clinical follow-up study
    • Lord G, Bancel P: The madreporic cementless total hip arthroplasty: new experimental data and a seven-year clinical follow-up study. Clin Orthop 176:67, 1983
    • (1983) Clin Orthop , vol.176 , pp. 67
    • Lord, G.1    Bancel, P.2
  • 7
    • 0026795145 scopus 로고
    • A quantitative evaluation of periprosthetic bone-remodeling after cementless total hip arthroplasty
    • Engh CA, McGovern TF, Bobyn JD, Harris WH: A quantitative evaluation of periprosthetic bone-remodeling after cementless total hip arthroplasty. J Bone Joint Surg 74A:1009, 1992
    • (1992) J Bone Joint Surg , vol.74 A , pp. 1009
    • Engh, C.A.1    McGovern, T.F.2    Bobyn, J.D.3    Harris, W.H.4
  • 8
    • 0021211621 scopus 로고
    • Human histology of the bone-porous metal implant interface
    • Bobyn JD, Engh CA: Human histology of the bone-porous metal implant interface. Orthopedics 7:1410, 1984
    • (1984) Orthopedics , vol.7 , pp. 1410
    • Bobyn, J.D.1    Engh, C.A.2
  • 9
    • 0030067508 scopus 로고    scopus 로고
    • The influence of clinical factors on periprosthetic bone remodeling
    • Sychterz CJ, Engh CA: The influence of clinical factors on periprosthetic bone remodeling. Clin Orthop 322:285, 1996
    • (1996) Clin Orthop , vol.322 , pp. 285
    • Sychterz, C.J.1    Engh, C.A.2
  • 10
    • 0027409719 scopus 로고
    • Dual-energy absorptiometry measurement of bone mineral density around porous-coated cementless femoral implants
    • Kilgus DJ, Shimaoka EE, Tipton JS, Eberle RW: Dual-energy absorptiometry measurement of bone mineral density around porous-coated cementless femoral implants. J Bone Joint Surg 75B:279, 1993
    • (1993) J Bone Joint Surg , vol.75 B , pp. 279
    • Kilgus, D.J.1    Shimaoka, E.E.2    Tipton, J.S.3    Eberle, R.W.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.