Volumn 200, Issue 3, 1996, Pages 843-850

Residual-limb shape change: Three-dimensional CT scan measurement and depiction in vivo

Author keywords

Computed tomography (CT), helical; Computed tomography (CT), image processing; Computed tomography (CT), three dimensional; Computed tomography (CT), utilization; Stents and prostheses; Tibia

Indexed keywords

ADULT; AGED; ALGORITHM; ARTICLE; BELOW KNEE AMPUTATION; CLINICAL ARTICLE; CLINICAL PROTOCOL; CONTROLLED STUDY; FEMALE; HUMAN; IMAGE PROCESSING; IMAGE RECONSTRUCTION; LEG PROSTHESIS; MALE; MEASUREMENT; PRIORITY JOURNAL; SOFT TISSUE; SPIRAL COMPUTER ASSISTED TOMOGRAPHY; THREE DIMENSIONAL IMAGING; VOLUMETRY;

EID: 0029787390     PISSN: 00338419     EISSN: None     Source Type: Journal    
DOI: 10.1148/radiology.200.3.8756942     Document Type: Article
Times cited : (32)

References (42)
  • 1
    • 0000968691 scopus 로고
    • A computerized system to manufacture prostheses for amputees in developing countries
    • Walsh NE, Lancaster JL, Faulkner V, Rogers WE. A computerized system to manufacture prostheses for amputees in developing countries. J Prosthet Orthot 1989; 1:165-181.
    • (1989) J Prosthet Orthot , vol.1 , pp. 165-181
    • Walsh, N.E.1    Lancaster, J.L.2    Faulkner, V.3    Rogers, W.E.4
  • 2
    • 0001403329 scopus 로고
    • The CANFIT system: Shape management technology for prosthetic and orthotic applications
    • Saunders CG, Bannon M, Sabiston RM, et al. The CANFIT system: shape management technology for prosthetic and orthotic applications. J Prosthet Orthot 1989; 1:122-130.
    • (1989) J Prosthet Orthot , vol.1 , pp. 122-130
    • Saunders, C.G.1    Bannon, M.2    Sabiston, R.M.3
  • 4
    • 0028197248 scopus 로고
    • Automated fabrication of mobility aids: Review of the AFMA process and VA/Seattle ShapeMaker software design
    • Boone DA, Harlan JS, Burgess EM. Automated fabrication of mobility aids: review of the AFMA process and VA/Seattle ShapeMaker software design. J Rehabil Res Dev 1994; 31:42-49.
    • (1994) J Rehabil Res Dev , vol.31 , pp. 42-49
    • Boone, D.A.1    Harlan, J.S.2    Burgess, E.M.3
  • 5
    • 0026924741 scopus 로고
    • Automated fabrication of mobility aids (AFMA): Below-knee CASD/CAM testing and evaluation program results
    • Houston VL, Burgess EM, Childress DS, et al. Automated fabrication of mobility aids (AFMA): below-knee CASD/CAM testing and evaluation program results. J Rehabil Res Dev 1992; 29:78-124.
    • (1992) J Rehabil Res Dev , vol.29 , pp. 78-124
    • Houston, V.L.1    Burgess, E.M.2    Childress, D.S.3
  • 6
    • 0001655846 scopus 로고
    • In situ evaluation of lower limb prosthesis fit by spiral computed tomography
    • Vannier M, Smith K, Commean P, Bhatia G. In situ evaluation of lower limb prosthesis fit by spiral computed tomography. Proc SPIE 1995; 2434:438-451.
    • (1995) Proc SPIE , vol.2434 , pp. 438-451
    • Vannier, M.1    Smith, K.2    Commean, P.3    Bhatia, G.4
  • 10
    • 0026998906 scopus 로고
    • Image registration of multimodality 3-D medical images by chamfer matching
    • Jiang HJ, Holton K, Robb RA. Image registration of multimodality 3-D medical images by chamfer matching. Proc SPIE 1992; 1660:356-366.
    • (1992) Proc SPIE , vol.1660 , pp. 356-366
    • Jiang, H.J.1    Holton, K.2    Robb, R.A.3
  • 11
    • 0028909461 scopus 로고
    • Anthropometric optical surface imaging system repeatability, precision, and validation
    • Kohn L, Cheverud J, Bhatia G, Commean P, Smith K, Vannier M. Anthropometric optical surface imaging system repeatability, precision, and validation. Ann Plast Surg 1995; 34:362-371.
    • (1995) Ann Plast Surg , vol.34 , pp. 362-371
    • Kohn, L.1    Cheverud, J.2    Bhatia, G.3    Commean, P.4    Smith, K.5    Vannier, M.6
  • 13
    • 0025184288 scopus 로고
    • The principal axes transformation: A method for image registration
    • Alpert NM, Bradshaw JF, Kennedy D, Correia JA. The principal axes transformation: a method for image registration. J Nucl Med 1990; 31:1717-1722.
    • (1990) J Nucl Med , vol.31 , pp. 1717-1722
    • Alpert, N.M.1    Bradshaw, J.F.2    Kennedy, D.3    Correia, J.A.4
  • 15
    • 0003936928 scopus 로고
    • Automatic analysis of medical images using a deformable textbook
    • Lemke HU, Inamura K, Jaffe CC, Vannier MW, eds. Berlin, Germany: Springer Verlag
    • Christensen GE, Miller MI, Marsh JL, Vannier MW. Automatic analysis of medical images using a deformable textbook. In: Lemke HU, Inamura K, Jaffe CC, Vannier MW, eds. Computer assisted radiology. Berlin, Germany: Springer Verlag, 1995; 146-151.
    • (1995) Computer Assisted Radiology , pp. 146-151
    • Christensen, G.E.1    Miller, M.I.2    Marsh, J.L.3    Vannier, M.W.4
  • 16
    • 0025351273 scopus 로고
    • Spiral volumetric CT with single-breath-hold technique, continuous transport, and continuous scanner rotation
    • Kalender WA, Seissler W, Klotz E, Vock P. Spiral volumetric CT with single-breath-hold technique, continuous transport, and continuous scanner rotation Radiology 1990; 176:181-183.
    • (1990) Radiology , vol.176 , pp. 181-183
    • Kalender, W.A.1    Seissler, W.2    Klotz, E.3    Vock, P.4
  • 17
    • 0025221610 scopus 로고
    • Computed tomography scanning with simultaneous patient translation
    • Crawford CR, King KF. Computed tomography scanning with simultaneous patient translation. Med Phys 1990; 17:967-982.
    • (1990) Med Phys , vol.17 , pp. 967-982
    • Crawford, C.R.1    King, K.F.2
  • 18
    • 0026048199 scopus 로고
    • Physical performance characteristics of spiral CT scanning
    • Kalender WA, Polacin A. Physical performance characteristics of spiral CT scanning. Med Phys 1991; 18:910-915.
    • (1991) Med Phys , vol.18 , pp. 910-915
    • Kalender, W.A.1    Polacin, A.2
  • 20
    • 0028298099 scopus 로고
    • A comparison of conventional and spiral CT: An experimental study on the detection of spherical lesions
    • Kalender WA, Polacin A, Süss C. A comparison of conventional and spiral CT: an experimental study on the detection of spherical lesions. J Comput Assist Tomogr 1994; 18:167-176.
    • (1994) J Comput Assist Tomogr , vol.18 , pp. 167-176
    • Kalender, W.A.1    Polacin, A.2    Süss, C.3
  • 22
    • 0026712389 scopus 로고
    • Evaluation of section sensitivity profiles and image noise in spiral CT
    • Polacin A, Kalender WA, Marchal G. Evaluation of section sensitivity profiles and image noise in spiral CT. Radiology 1992; 185:29-35.
    • (1992) Radiology , vol.185 , pp. 29-35
    • Polacin, A.1    Kalender, W.A.2    Marchal, G.3
  • 23
    • 0028258284 scopus 로고
    • Longitudinal resolution in volumetric x-ray computerized tomography: Analytical comparison between conventional and helical computerized tomography
    • Wang G, Vannier MW. Longitudinal resolution in volumetric x-ray computerized tomography: analytical comparison between conventional and helical computerized tomography. Med Phys 1994; 21: 429-433.
    • (1994) Med Phys , vol.21 , pp. 429-433
    • Wang, G.1    Vannier, M.W.2
  • 24
    • 0027144470 scopus 로고
    • Helical CT image noise: Analytical results
    • Wang G, Vannier MW. Helical CT image noise: analytical results. Med Phys 1993; 20:1635-1640.
    • (1993) Med Phys , vol.20 , pp. 1635-1640
    • Wang, G.1    Vannier, M.W.2
  • 25
    • 0027953006 scopus 로고
    • Injuries associated with MR imaging: Survey of safety records and methods used to screen patients for metallic foreign bodies before imaging
    • Boutin RD, Briggs JE, Williamson MR. Injuries associated with MR imaging: survey of safety records and methods used to screen patients for metallic foreign bodies before imaging. AJR 1994; 162:189-194.
    • (1994) AJR , vol.162 , pp. 189-194
    • Boutin, R.D.1    Briggs, J.E.2    Williamson, M.R.3
  • 26
    • 0026836448 scopus 로고
    • MR imaging and metallic implants for anterior cruciate ligament reconstruction: Assessment of ferromagnetism and artifact
    • Shellock FG, Mink JH, Curtin S, Friedman MJ. MR imaging and metallic implants for anterior cruciate ligament reconstruction: assessment of ferromagnetism and artifact. JMRI 1992; 2:225-228.
    • (1992) JMRI , vol.2 , pp. 225-228
    • Shellock, F.G.1    Mink, J.H.2    Curtin, S.3    Friedman, M.J.4
  • 28
    • 0028064850 scopus 로고
    • Imaging techniques for the assessment of body composition
    • Fuller MF, Fowler PA, McNeill G, Foster MA. Imaging techniques for the assessment of body composition. J Nutr 1994; 124(suppl):1546-1550.
    • (1994) J Nutr , vol.124 , Issue.SUPPL. , pp. 1546-1550
    • Fuller, M.F.1    Fowler, P.A.2    McNeill, G.3    Foster, M.A.4
  • 29
    • 0010237932 scopus 로고
    • Validation of spiral computed tomography and optical surface scanning for 3D limb prosthesis design
    • Tempe, Ariz: IMAGE Society
    • Commean PK, Smith KE, Bhatia G, Vannier MW. Validation of spiral computed tomography and optical surface scanning for 3D limb prosthesis design. In: 1994 IMAGE VII conference proceedings. Tempe, Ariz: IMAGE Society, 1994; 369-381.
    • (1994) 1994 IMAGE VII Conference Proceedings , pp. 369-381
    • Commean, P.K.1    Smith, K.E.2    Bhatia, G.3    Vannier, M.W.4
  • 30
    • 84965487160 scopus 로고
    • Automated lower limb prosthesis design
    • Robb RA, ed. Visualization in biomedical computing.
    • Bhatia G, Commean PK, Smith KE, Vannier MW. Automated lower limb prosthesis design. In: Robb RA, ed. Visualization in biomedical computing. Proc SPIE 1994; 2359:493-503.
    • (1994) Proc SPIE , vol.2359 , pp. 493-503
    • Bhatia, G.1    Commean, P.K.2    Smith, K.E.3    Vannier, M.W.4
  • 32
    • 0021644217 scopus 로고
    • Distance transformation in arbitrary dimensions
    • Borgefors G. Distance transformation in arbitrary dimensions. Comput Vision Graph Image Processing 1984; 27:321-345.
    • (1984) Comput Vision Graph Image Processing , vol.27 , pp. 321-345
    • Borgefors, G.1
  • 33
    • 0024104158 scopus 로고
    • Heirarchial chamfer matching: A parametric edge matching algorithm
    • Borgefors G. Heirarchial chamfer matching: a parametric edge matching algorithm. IEEE Trans Pattern Analysis Machine Intell 1988; 10:849-865.
    • (1988) IEEE Trans Pattern Analysis Machine Intell , vol.10 , pp. 849-865
    • Borgefors, G.1
  • 34
    • 0000221594 scopus 로고
    • Evaluating the accuracy of three-dimensional image registration algorithms used in multimodal image fusion
    • Robb RA, ed. Visualization in biomedical computing.
    • Taneja U, Holten KS, Camp JC, Robb RA. Evaluating the accuracy of three-dimensional image registration algorithms used in multimodal image fusion. In: Robb RA, ed. Visualization in biomedical computing. Proc SPIE 1994; 2359:238-250.
    • (1994) Proc SPIE , vol.2359 , pp. 238-250
    • Taneja, U.1    Holten, K.S.2    Camp, J.C.3    Robb, R.A.4
  • 35
    • 0024760875 scopus 로고
    • Analyze: A comprehensive, operator-interactive software package for multidimensional medical image display and analysis
    • Robb RA, Hanson DP, Karwoski RA, Larson AG, Workman EL, Stacy MC. Analyze: a comprehensive, operator-interactive software package for multidimensional medical image display and analysis. Comput Med Imaging Graph 1989; 13:433-454.
    • (1989) Comput Med Imaging Graph , vol.13 , pp. 433-454
    • Robb, R.A.1    Hanson, D.P.2    Karwoski, R.A.3    Larson, A.G.4    Workman, E.L.5    Stacy, M.C.6
  • 36
    • 0026994610 scopus 로고
    • New approach to 3-D registration of multimodality medical images by surface matching
    • Robb RA, ed. Visualization in biomedical computing.
    • Jiang H, Robb RA, Holton KS. New approach to 3-D registration of multimodality medical images by surface matching. In: Robb RA, ed. Visualization in biomedical computing. Proc SPIE 1992; 1808:196-213.
    • (1992) Proc SPIE , vol.1808 , pp. 196-213
    • Jiang, H.1    Robb, R.A.2    Holton, K.S.3
  • 39
    • 0030005557 scopus 로고    scopus 로고
    • Below knee residua surface measurement precision and repeatability
    • Commean P, Smith K, Cheverud J, Vannier M. Below knee residua surface measurement precision and repeatability. Arch Phys Med Rehabil 1996; 77:477-486.
    • (1996) Arch Phys Med Rehabil , vol.77 , pp. 477-486
    • Commean, P.1    Smith, K.2    Cheverud, J.3    Vannier, M.4
  • 40
    • 0029028851 scopus 로고
    • Validation of spiral CT and optical surface scanning for lower limb stump volumetry
    • Smith KE, Commean PK, Bhatia G, Vannier MW. Validation of spiral CT and optical surface scanning for lower limb stump volumetry. Prosthet Orthot Int 1995; 19: 97-107.
    • (1995) Prosthet Orthot Int , vol.19 , pp. 97-107
    • Smith, K.E.1    Commean, P.K.2    Bhatia, G.3    Vannier, M.W.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.