Volumn 10, Issue 3, 1991, Pages 249-255

Positron Emission Tomography with a Large Axial Acceptance Angle: Signal-To-Noise Considerations

Author keywords

[No Author keywords available]

Indexed keywords

GAMMA RAYS - SCATTERING; IMAGE PROCESSING - RECONSTRUCTION; MATHEMATICAL STATISTICS; NOISE, SPURIOUS SIGNAL - SIGNAL TO NOISE RATIO; PHOTODETECTORS;

EID: 0026221858     PISSN: 02780062     EISSN: 1558254X     Source Type: Journal    
DOI: 10.1109/42.97572     Document Type: Article
Times cited : (12)

References (22)
  • 1
    • 0001549484 scopus 로고
    • The effect of collimation on scatter fraction in multi-slice PET
    • C. J. Thompson, “The effect of collimation on scatter fraction in multi-slice PET,” IEEE Trans. Nucl. Sci., vol. 35, pp. 598–602, 1988.
    • (1988) IEEE Trans. Nucl. Sci. , vol.35 , pp. 598-602
    • Thompson, C.J.1
  • 2
    • 0025414706 scopus 로고
    • Analytical study of the effect of collimation on the performance of PET cameras in 3-D imaging
    • A. Maze and R. Lecomte, “Analytical study of the effect of collimation on the performance of PET cameras in 3-D imaging,” IEEE Trans. Nucl. Sci., vol. 37, pp. 823–831, 1990.
    • (1990) IEEE Trans. Nucl. Sci. , vol.37 , pp. 823-831
    • Maze, A.1    Lecomte, R.2
  • 4
    • 0018939380 scopus 로고
    • Method for optimizing side shielding in positronemission tomographs and for comparing detector materials
    • S. E. Derenzo, “Method for optimizing side shielding in positronemission tomographs and for comparing detector materials,” J. Nucl. Med., vol. 21, pp. 971–977, 1980.
    • (1980) J. Nucl. Med. , vol.21 , pp. 971-977
    • Derenzo, S.E.1
  • 5
    • 0021387241 scopus 로고
    • Performance of positron imaging systems as a function of energy threshold and shielding depth
    • D. Mankoff and G. Muehllehner, “Performance of positron imaging systems as a function of energy threshold and shielding depth,” IEEE Trans. Med. Imaging, vol. MI-3, pp. 18–24, 1984.
    • (1984) IEEE Trans. Med. Imaging , vol.MI-3 , pp. 18-24
    • Mankoff, D.1    Muehllehner, G.2
  • 6
    • 0025414253 scopus 로고
    • Measuring PET scanner sensitivity: Relating countrates to image signal-to-noise ratios using noise equivalent counts
    • S. C. Strother, M. E. Casey, and E. J. Hoffman, “Measuring PET scanner sensitivity: Relating countrates to image signal-to-noise ratios using noise equivalent counts,” IEEE Trans. Nucl. Sci., vol. 37, pp. 783-788, 1990.
    • (1990) IEEE Trans. Nucl. Sci. , vol.37 , pp. 783-788
    • Strother, S.C.1    Casey, M.E.2    Hoffman, E.J.3
  • 8
    • 0021480012 scopus 로고
    • Spherical positron emission tomograph (S-PET) I—Performance analysis
    • Z. H. Cho, K. S. Hong, and S. K. Hilal, “Spherical positron emission tomograph (S-PET) I—Performance analysis,” Nucl. Instr. Meth., vol. 225, pp. 422–438, 1984.
    • (1984) Nucl. Instr. Meth. , vol.225 , pp. 422-438
    • Cho, Z.H.1    Hong, K.S.2    Hilal, S.K.3
  • 11
    • 0023984278 scopus 로고
    • Constrained Fourier space method for compensation of missing data in emission computed tomography
    • J. S. Karp, G. Muehllehner, and R. Lewitt, “Constrained Fourier space method for compensation of missing data in emission computed tomography,” IEEE Trans. Med. Imaging, vol. 7, pp. 21–25, 1988.
    • (1988) IEEE Trans. Med. Imaging , vol.7 , pp. 21-25
    • Karp, J.S.1    Muehllehner, G.2    Lewitt, R.3
  • 12
    • 0023640412 scopus 로고
    • Treatment of axial data in three-dimensional PET
    • M. E. Daube-Witherspoon and G. Muehllehner, “Treatment of axial data in three-dimensional PET,” J. Nucl. Med., vol. 28, pp. 1717–1724, 1987.
    • (1987) J. Nucl. Med. , vol.28 , pp. 1717-1724
    • Daube-Witherspoon, M.E.1    Muehllehner, G.2
  • 13
    • 0024610693 scopus 로고
    • Analytic 3D image reconstruction using all detected events
    • P. E. Kinahan and J. G. Rogers, “Analytic 3D image reconstruction using all detected events,” IEEE Trans. Nucl. Sci., vol. 36, pp. 964–968, 1989.
    • (1989) IEEE Trans. Nucl. Sci. , vol.36 , pp. 964-968
    • Kinahan, P.E.1    Rogers, J.G.2
  • 14
    • 0025414801 scopus 로고
    • Accelerated image reconstruction for a cylindrical positron tomograph using Fourier domain methods
    • C. W. Steams, D. A. Chesler, and G. L. Brownell, “Accelerated image reconstruction for a cylindrical positron tomograph using Fourier domain methods,” IEEE Trans. Nucl. Sci., vol. 37, pp. 773–77, 1990.
    • (1990) IEEE Trans. Nucl. Sci. , vol.37 , pp. 773-777
    • Steams, C.W.1    Chesler, D.A.2    Brownell, G.L.3
  • 15
    • 0024508539 scopus 로고
    • Three-dimensional image reconstruction from complete projections
    • M. Defrise, D. W. Townsend, and R. Clack, “Three-dimensional image reconstruction from complete projections,” Phys. Med. Biol., vol. 34, pp. 573–587, 1989.
    • (1989) Phys. Med. Biol. , vol.34 , pp. 573-587
    • Defrise, M.1    Townsend, D.W.2    Clack, R.3
  • 16
    • 0018921312 scopus 로고
    • Fully three-dimensional positron emission tomography
    • J. G. Colsher, “Fully three-dimensional positron emission tomography,” Phys. Med. Biol., vol. 25, pp. 103–115, 1980.
    • (1980) Phys. Med. Biol. , vol.25 , pp. 103-115
    • Colsher, J.G.1
  • 17
    • 0020660172 scopus 로고
    • Correction for scattered radiation in a ring detector positron camera by integral transformation of the projections
    • M. Bergstrom, L. Eriksson, and C. Bohm, et al., “Correction for scattered radiation in a ring detector positron camera by integral transformation of the projections,” J. Comput. Assist. Tomograph., vol. 7, pp. 42–50, 1983.
    • (1983) J. Comput. Assist. Tomograph. , vol.7 , pp. 42-50
    • Bergstrom, M.1    Eriksson, L.2    Bohm, C.3
  • 18
    • 0026221665 scopus 로고    scopus 로고
    • Cross plane scattering correction–Point source deconvolution in PET
    • L. Shao and J. S. Karp, “Cross plane scattering correction—Point source deconvolution in PET,” see this issue, pp. 234–239.
    • See this issue , pp. 234-239
    • Shao, L.1    Karp, J.S.2
  • 19
    • 0021210513 scopus 로고
    • A comparison of physical image indices and observer performance in the radiographic detection of nylon beads
    • L. N. D. Loo, K. Doi, and C. E. Metz, “A comparison of physical image indices and observer performance in the radiographic detection of nylon beads,” Phys. Med. Bio., vol. 29, pp. 837–856, 1984.
    • (1984) Phys. Med. Bio. , vol.29 , pp. 837-856
    • Loo, L.N.D.1    Doi, K.2    Metz, C.E.3
  • 20
    • 0001276637 scopus 로고
    • The effect of detector performance on high countrate PET imaging with a tomograph based on positron-sensitive detectors
    • D. A. Mankoff, G. Muehllehner, and J. S. Karp, “The effect of detector performance on high countrate PET imaging with a tomograph based on positron-sensitive detectors,” IEEE Nucl. Sci., vol. 35, pp. 592–597, 1988.
    • (1988) IEEE Nucl. Sci. , vol.35 , pp. 592-597
    • Mankoff, D.A.1    Muehllehner, G.2    Karp, J.S.3
  • 21
    • 0343316309 scopus 로고    scopus 로고
    • Physical performance of a new commercial positron tomogragh with retractable septa
    • T. J. Spinks, T. Jones, and D. L. Bailey, et al., “Physical performance of a new commercial positron tomogragh with retractable septa,” in Conf. Rec. IEEE 1990 Nuclear Sci. Symp., pp. 1313–1317.
    • Conf. Rec. IEEE 1990 Nuclear Sci. Symp. , pp. 1313-1317
    • Spinks, T.J.1    Jones, T.2    Bailey, D.L.3
  • 22
    • 0024612105 scopus 로고
    • The effect of collimation on singles rates in multislice PET
    • C. J. Thompson, “The effect of collimation on singles rates in multislice PET,” IEEE Trans. Nucl. Sci., vol. 36, pp. 1072–1077, 1989.
    • (1989) IEEE Trans. Nucl. Sci. , vol.36 , pp. 1072-1077
    • Thompson, C.J.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.