메뉴 건너뛰기




Volumn 10, Issue 3, 1991, Pages 234-239

Cross-Plane Scattering Correction—Point Source Deconvolution in PET

Author keywords

[No Author keywords available]

Indexed keywords

COMPUTER SIMULATION; GAMMA RAYS - SCATTERING; IMAGE PROCESSING; MATHEMATICAL TECHNIQUES - CURVE FITTING; MATHEMATICAL TECHNIQUES - ITERATIVE METHODS;

EID: 0026221665     PISSN: 02780062     EISSN: 1558254X     Source Type: Journal    
DOI: 10.1109/42.97570     Document Type: Article
Times cited : (55)

References (10)
  • 2
    • 0001549484 scopus 로고
    • The effect of collimation on scatter fraction in multi-slice PET
    • Feb
    • C. J. Thompson, “The effect of collimation on scatter fraction in multi-slice PET,” IEEE Trans. Nucl. Sci., vol. 35, pp. 598–602, Feb. 1988.
    • (1988) IEEE Trans. Nucl. Sci. , vol.35 , pp. 598-602
    • Thompson, C.J.1
  • 4
    • 0343316309 scopus 로고    scopus 로고
    • Physical performance of a new commercial position tomograph with retractable Septa
    • T. J. Spinks, T. Jones, D. L. Bailey et. al., “Physical performance of a new commercial position tomograph with retractable Septa,” in Conf. Rec. IEEE 1990 Nucl. Sci. Symp., pp. 1313–1317.
    • Conf. Rec. IEEE 1990 Nucl. Sci. Symp. , pp. 1313-1317
    • Spinks, T.J.1    Jones, T.2    Bailey, D.L.3
  • 5
    • 0020640629 scopus 로고
    • A Monte-Carlo simulation of Compton scattering in position emission tomography
    • J. Logan and H. L. Bernstein, “A Monte-Carlo simulation of Compton scattering in position emission tomography,” J. Comput. Assist. Tomograph., vol. 7, no. 2, pp. 316–320, 1983.
    • (1983) J. Comput. Assist. Tomograph. , vol.7 , Issue.2 , pp. 316-320
    • Logan, J.1    Bernstein, H.L.2
  • 6
    • 84941469581 scopus 로고
    • Analysis of scatter deconvolution technique in PET using Monte-Carlo simulation
    • Abstract, Apr
    • B. Bendriem, W. H. Wong, C. Micheal, S. S. Adler, and N. A. Mullani, “Analysis of scatter deconvolution technique in PET using Monte-Carlo simulation,” Abstract, in Proc. 34th Ann. Meet., vol. 28, p. 681, Apr. 1987.
    • (1987) Proc. 34th Ann. Meet. , vol.28 , pp. 681
    • Bendriem, B.1    Wong, W.H.2    Micheal, C.3    Adler, S.S.4    Mullani, N.A.5
  • 7
    • 0020660172 scopus 로고
    • Correction for scattered radiation in a ring detector positron camera by integral transformation of the projections
    • M. Bergstrom, L. Eriksson, C. Bohm, G. Blomqvist, and J. Litton, “Correction for scattered radiation in a ring detector positron camera by integral transformation of the projections,” J. Comput. Assist. Tomograh., vol. 7, no. 1, pp. 42–50, 1983.
    • (1983) J. Comput. Assist. Tomograh. , vol.7 , Issue.1 , pp. 42-50
    • Bergstrom, M.1    Eriksson, L.2    Bohm, C.3    Blomqvist, G.4    Litton, J.5
  • 9
    • 0025416078 scopus 로고
    • A projector, back-projector pair which accounts for the two-dimensional depth and distance dependent blurring in SPECT
    • B. C. Penney and M. A. King, “A projector, back-projector pair which accounts for the two-dimensional depth and distance dependent blurring in SPECT,” IEEE Trans. Nucl. Sci., vol. 37, pp. 681–686, 1990.
    • (1990) IEEE Trans. Nucl. Sci. , vol.37 , pp. 681-686
    • Penney, B.C.1    King, M.A.2
  • 10
    • 0023584327 scopus 로고
    • Generalized scatter correction method in SPECT using point scatter distribution functions
    • P. Msaki, B. Axelsson, C M. Dahl, and S. A. Larrson, “Generalized scatter correction method in SPECT using point scatter distribution functions,” J. Nucl. Med., no. 28, pp. 1861–1869, 1987.
    • (1987) J. Nucl. Med. , Issue.28 , pp. 1861-1869
    • Msaki, P.1    Axelsson, B.2    Dahl, C.M.3    Larrson, S.A.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.