메뉴 건너뛰기




Volumn 34, Issue 2, 1987, Pages 172-178

Trace Chemical Vapor Detection Using SAW Delay Line Oscillators

Author keywords

[No Author keywords available]

Indexed keywords

ACOUSTIC SURFACE WAVE DEVICES - DESIGN; TRACE ANALYSIS; VAPORS - MEASUREMENTS;

EID: 0023312147     PISSN: 08853010     EISSN: None     Source Type: Journal    
DOI: 10.1109/T-UFFC.1987.26929     Document Type: Article
Times cited : (85)

References (12)
  • 1
    • 0000711135 scopus 로고
    • Surface acoustic wave probe for chemical analysis, Parts I—III
    • H. Wohltjen and R. E. Dessy, “Surface acoustic wave probe for chemical analysis, Parts I—III,” Analytical Chem., vol. 5, no. 9, pp. 1458–1475, 1979.
    • (1979) Analytical Chem , vol.5 , Issue.9 , pp. 1458-1475
    • Wohltjen, H.1    Dessy, R.E.2
  • 3
    • 0020142109 scopus 로고
    • A thin membrane surface acoustic wave vapor sensing device
    • C. T. Chuang, R. M. White, J. J. Bernstein, “A thin membrane surface acoustic wave vapor sensing device,” Electron. Dev. Lett., vol. EDL-3, no. 6, pp. 145–148, 1982.
    • (1982) Electron. Dev. Lett. , vol.EDL-3 , Issue.6 , pp. 145-148
    • Chuang, C.T.1    White, R.M.2    Bernstein, J.J.3
  • 5
    • 0021457034 scopus 로고
    • Mechanism of operation and design considerations for surface acoustic wave vapor sensors
    • H. Wohltjen, “Mechanism of operation and design considerations for surface acoustic wave vapor sensors,” Sensors and Actuators, pp. 307–325, 1984.
    • (1984) Sensors and Actuators , pp. 307-325
    • Wohltjen, H.1
  • 6
    • 0021460971 scopus 로고
    • Polyethylene maleate)cyclopentadiene: A model reactive polymer-vapor system for evaluation of a SAW microsensor
    • A. Snow and H. Wohltjen, “Polyethylene maleate)cyclopentadiene: A model reactive polymer-vapor system for evaluation of a SAW microsensor,” Analytical Chem., vol. 56, no. 8, pp. 1411–1416, 1984.
    • (1984) Analytical Chem. , vol.56 , Issue.8 , pp. 1411-1416
    • Snow, A.1    Wohltjen, H.2
  • 8
    • 84915243070 scopus 로고    scopus 로고
    • A SAW-chemosensor for NO2 gas-concentration measurement
    • A. W. Barendsz et al. “A SAW-chemosensor for NO2 gas-concentration measurement,” in Proc. 1985 IEEE Ultrason. Symp.
    • Proc. 1985 IEEE Ultrason. Symp
    • Barendsz, A.W.1
  • 10
    • 0022085543 scopus 로고
    • A vapor sensitive chemiresistor fabricated with planar microelectrodes and a Langmuir-Blodgett organic semiconductor film
    • July
    • H. Wohltjen, W. R. Barger, A. W. Snow, and N. L. Jarvis, “A vapor sensitive chemiresistor fabricated with planar microelectrodes and a Langmuir-Blodgett organic semiconductor film,” IEEE Trans. Electron. Dev., vol. ED-32, pp. 1170–1174, July 1985.
    • (1985) IEEE Trans. Electron. Dev. , vol.ED-32 , pp. 1170-1174
    • Wohltjen, H.1    Barger, W.R.2    Snow, A.W.3    Jarvis, N.L.4
  • 11
    • 0017556722 scopus 로고
    • Applications of the piezoelectric crystal detector in analytical chemistry
    • J. Hlavay and G. G. Guilbault, “Applications of the piezoelectric crystal detector in analytical chemistry,” Analytical Chem., vol. 49, no. 13, pp. 1890–1898, 1977.
    • (1977) Analytical Chem. , vol.49 , Issue.13 , pp. 1890-1898
    • Hlavay, J.1    Guilbault, G.G.2
  • 12
    • 37049112273 scopus 로고
    • Piezoelectric crystals for mass and chemical measurements
    • J. F. Alder and J. J. McCallum, “Piezoelectric crystals for mass and chemical measurements,” The Analyst, vol. 108, pp. 1291, 1169–1189, 1983.
    • (1983) The Analyst , vol.108 , pp. 1189-1291
    • Alder, J.F.1    McCallum, J.J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.