메뉴 건너뛰기




Volumn 25, Issue 2-3, 2001, Pages 465-474

A compilation of silicon and thirty one trace elements measured in the natural river water reference material SLRS-4 (NRC-CNRC)

Author keywords

Compilation; ICP MS; Rare earth elements; River water reference material; Silicon; SLRS 4; Trace elements

Indexed keywords


EID: 0013453497     PISSN: 01505505     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.1751-908x.2001.tb00617.x     Document Type: Article
Times cited : (106)

References (19)
  • 1
    • 0003085631 scopus 로고    scopus 로고
    • A routine method for oxide and hydroxide interference corrections in ICP-MS chemical analysis of environmental and geological samples
    • Aries S., Valladon M., Polvé M. and Dupré B. (2000) A routine method for oxide and hydroxide interference corrections in ICP-MS chemical analysis of environmental and geological samples. Geostandards Newsletter The Journal of Geostandards and Geoanarysis, 24, 19-31.
    • (2000) Geostandards Newsletter the Journal of Geostandards and Geoanarysis , vol.24 , pp. 19-31
    • Aries, S.1    Valladon, M.2    Polvé, M.3    Dupré, B.4
  • 2
    • 0030245275 scopus 로고    scopus 로고
    • High temperature hydraulic high-pressure nebulization: A recent nebulization principle for sample introduction
    • Berndt T.H. and Yanez J. (1996) High temperature hydraulic high-pressure nebulization: A recent nebulization principle for sample introduction. Journal of Analytical Atomic Spectrometry, 11, 703-712.
    • (1996) Journal of Analytical Atomic Spectrometry , vol.11 , pp. 703-712
    • Berndt, T.H.1    Yanez, J.2
  • 3
    • 67650258640 scopus 로고    scopus 로고
    • Validation d'un protocole permmettant le dosage simultané des cations majeurs et traces dans les eaux douces naturelles par ICP-MS
    • Bouhnik-Le Coz M., Petitjean P., Serrat E. and Gruau G. (2001) Validation d'un protocole permmettant le dosage simultané des cations majeurs et traces dans les eaux douces naturelles par ICP-MS. Les Cahiers Techniques, Editions Géosciences Rennes, 1, 82pp.
    • (2001) Les Cahiers Techniques, Editions Géosciences Rennes , vol.1
    • Bouhnik-Le Coz, M.1    Petitjean, P.2    Serrat, E.3    Gruau, G.4
  • 5
    • 85061195599 scopus 로고
    • Aqueous geochemistry of rare earth elements
    • Ribbe P. (ed.), Geochemistry and mineralogy of rare earth elements. Mineralogical Society of America
    • Brookins D.G. (1989) Aqueous geochemistry of rare earth elements. In: Ribbe P. (ed.), Geochemistry and mineralogy of rare earth elements. Mineralogical Society of America, Reviews in Mineralogy, 21, 201-223.
    • (1989) Reviews in Mineralogy , vol.21 , pp. 201-223
    • Brookins, D.G.1
  • 6
    • 0000089484 scopus 로고    scopus 로고
    • Routine analysis of trace elements in geological samples using flow-injection and low-pressure on-line liquid chromatography ICP-MS: A study of geochemical reference materials BR, DR-N, UB-N, ANG and GH
    • Carignan J., Hild P., Mevelle G., Morel J. and Yeghicheyan D. (2001) Routine analysis of trace elements in geological samples using flow-injection and low-pressure on-line liquid chromatography ICP-MS: A study of geochemical reference materials BR, DR-N, UB-N, ANG and GH. Geostandards Newsletter. The Journal of Geostandards and Geoanafysis, 25, 187-198.
    • (2001) Geostandards Newsletter. the Journal of Geostandards and Geoanafysis , vol.25 , pp. 187-198
    • Carignan, J.1    Hild, P.2    Mevelle, G.3    Morel, J.4    Yeghicheyan, D.5
  • 9
    • 0021069283 scopus 로고
    • Aqueous and sedimentary geochemistry of rare earth elements
    • Henderson P. (ed.). Elsevier Science (Amsterdam)
    • Fleet A.J. (1984) Aqueous and sedimentary geochemistry of rare earth elements. In: Henderson P. (ed.). Rare earth elements geochemistry. Elsevier Science (Amsterdam), 343-373.
    • (1984) Rare Earth Elements Geochemistry , pp. 343-373
    • Fleet, A.J.1
  • 10
    • 0026714261 scopus 로고
    • Analytical improvement of pneumatic nebulization in ICP-MS by desolvation
    • Jakubowski N., Feldmann I. and Stuewert D. (1992) Analytical improvement of pneumatic nebulization in ICP-MS by desolvation. Spectrochimica Acta, 47B, 107-118.
    • (1992) Spectrochimica Acta , vol.47 B , pp. 107-118
    • Jakubowski, N.1    Feldmann, I.2    Stuewert, D.3
  • 12
    • 0000151143 scopus 로고    scopus 로고
    • A table of polyatomic interferences in ICP-MS
    • May T.W. and Wiedmeyer R.H. (1998) A table of polyatomic interferences in ICP-MS. Atomic Spectroscopy, 19, 150-155.
    • (1998) Atomic Spectroscopy , vol.19 , pp. 150-155
    • May, T.W.1    Wiedmeyer, R.H.2
  • 16
    • 0028484368 scopus 로고
    • Characterization of polyatomic ion interferences in inductively coupled plasma-mass spectrometry using a high resolution mass spectrometer
    • Reed N.M., Cairns R.O. and Hutton R.C. (1994) Characterization of polyatomic ion interferences in inductively coupled plasma-mass spectrometry using a high resolution mass spectrometer. Journal of Analytical Atomic Spectrometry, 9, 881-896.
    • (1994) Journal of Analytical Atomic Spectrometry , vol.9 , pp. 881-896
    • Reed, N.M.1    Cairns, R.O.2    Hutton, R.C.3
  • 17
    • 20544468105 scopus 로고    scopus 로고
    • Transfer of atmospheric boron from oceans to continents: An investigation using precipitation waters and epiphytic lichens
    • Rose E.F., Carignan J. and Chaussidon M. (2000) Transfer of atmospheric boron from oceans to continents: An investigation using precipitation waters and epiphytic lichens. AGU and Geochemical Society publication, G31, 15pp.
    • (2000) AGU and Geochemical Society Publication , vol.G31
    • Rose, E.F.1    Carignan, J.2    Chaussidon, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.