-
1
-
-
25044465136
-
Determination of lead, uranium, thorium and thallium in silicate glass standard materials by isotope dilution mass spectrometry
-
Barnes I.L, Garner EL, Gramlich J.W., Moore L.J., Murphy T.J., Machlan LA., Shields W.R., Tatsumoto M. and Knight R.J. (1973) Determination of lead, uranium, thorium and thallium in silicate glass standard materials by isotope dilution mass spectrometry. Analytical Chemistry, 45, 880-885.
-
(1973)
Analytical Chemistry
, vol.45
, pp. 880-885
-
-
Barnes, I.L.1
Garner, E.L.2
Gramlich, J.W.3
Moore, L.J.4
Murphy, T.J.5
Machlan, L.A.6
Shields, W.R.7
Tatsumoto, M.8
Knight, R.J.9
-
2
-
-
27644522483
-
Determination of trace concentration of boron and uranium in glass by nuclear track technique
-
Carpenter B.S. (1972) Determination of trace concentration of boron and uranium in glass by nuclear track technique. Analytical Chemistry, 44, 600-602.
-
(1972)
Analytical Chemistry
, vol.44
, pp. 600-602
-
-
Carpenter, B.S.1
-
3
-
-
33745127453
-
A series of trace element standards in a glass matrix for the National Bureau of Standards
-
Erickson A.A. and Williams J.P. (1970) A series of trace element standards in a glass matrix for the National Bureau of Standards. Coming Glass Works Report, L - 1169, 24pp.
-
(1970)
Coming Glass Works Report
, vol.L-1169
-
-
Erickson, A.A.1
Williams, J.P.2
-
4
-
-
0001651269
-
Ultra-trace element analysis of SRM 616 and 614 using laser ablation microprobe inductively coupled plasma-mass spectrometry (LAM-ICP-MS): A comparison with secondary ion mass spectrometry (SIMS)
-
Horn I., Hinton R.W., Jackson S.E. and Longerich H.P. (1997) Ultra-trace element analysis of SRM 616 and 614 using laser ablation microprobe inductively coupled plasma-mass spectrometry (LAM-ICP-MS): a comparison with secondary ion mass spectrometry (SIMS). Geostandards Newsletter The Journal of Geostandards and Geoanalysis, 21, 191-203.
-
(1997)
Geostandards Newsletter the Journal of Geostandards and Geoanalysis
, vol.21
, pp. 191-203
-
-
Horn, I.1
Hinton, R.W.2
Jackson, S.E.3
Longerich, H.P.4
-
5
-
-
0025592457
-
Ion microprobe trace element analysis of silicates: Measurement of multi-element glasses
-
Hinton R.W. (1990) Ion microprobe trace element analysis of silicates: Measurement of multi-element glasses. Chemical Geology, 83, 11-25.
-
(1990)
Chemical Geology
, vol.83
, pp. 11-25
-
-
Hinton, R.W.1
-
6
-
-
33751102195
-
Ion probe measurements of National Institute of Standards and Technology standard reference material SRM 610 glass, trace elements
-
Hinton R.W., Harte B. and Witt-Eichschen G. (1995) Ion probe measurements of National Institute of Standards and Technology standard reference material SRM 610 glass, trace elements. Analyst, 120, 1315-1319.
-
(1995)
Analyst
, vol.120
, pp. 1315-1319
-
-
Hinton, R.W.1
Harte, B.2
Witt-Eichschen, G.3
-
7
-
-
0004328081
-
-
ISO Guide 33 International Organisation for Standardisation (Geneva)
-
ISO Guide 33 (1989) Uses of certified reference materials. International Organisation for Standardisation (Geneva), 12pp.
-
(1989)
Uses of Certified Reference Materials
-
-
-
9
-
-
0027091911
-
The application of laser oblation microprobe inductively coupled plasma-mass spectrometry (LAM-ICP-MS) to in situ trace element determinations in minerals
-
Jackson S.E., Longerich H.P., Dunning G.R. and Fryer B.J. (1992) The application of laser oblation microprobe inductively coupled plasma-mass spectrometry (LAM-ICP-MS) to in situ trace element determinations in minerals. Canadian Mineralogist, 30, 1049-1064.
-
(1992)
Canadian Mineralogist
, vol.30
, pp. 1049-1064
-
-
Jackson, S.E.1
Longerich, H.P.2
Dunning, G.R.3
Fryer, B.J.4
-
10
-
-
0028895345
-
Measurements of trace elements in basalts and their phenocrysts by laser probe microanalysis inductively coupled plasma-mass spectrometry (LPMA-ICP-MS)
-
Jeffries T.E., Perkins W.T. and Pearce N.J.G. (1995) Measurements of trace elements in basalts and their phenocrysts by laser probe microanalysis inductively coupled plasma-mass spectrometry (LPMA-ICP-MS). Chemical Geology, 121, 131-144.
-
(1995)
Chemical Geology
, vol.121
, pp. 131-144
-
-
Jeffries, T.E.1
Perkins, W.T.2
Pearce, N.J.G.3
-
11
-
-
0030783204
-
The homogeneity of reference materials
-
Kane J.S. (1997) The homogeneity of reference materials. Analyst, 122, 1289-1292.
-
(1997)
Analyst
, vol.122
, pp. 1289-1292
-
-
Kane, J.S.1
-
12
-
-
0003165745
-
Determination of trace elements in silicate matrices by differential cathode ray polarography
-
Maienthal E.J. (1973) Determination of trace elements in silicate matrices by differential cathode ray polarography Analytical Chemistry, 45, 644-648.
-
(1973)
Analytical Chemistry
, vol.45
, pp. 644-648
-
-
Maienthal, E.J.1
-
13
-
-
33645199697
-
Trace determination of rubidium and strontium in silicate glass standard reference materials
-
Moore L.J., Moody J.R., Barnes I.L, Gramlich J.W., Murphy T.J., Paulsen P.J. and Shields W.R. (1973) Trace determination of rubidium and strontium in silicate glass standard reference materials. Analytical Chemistry, 45, 2384-2487
-
(1973)
Analytical Chemistry
, vol.45
, pp. 2384-2487
-
-
Moore, L.J.1
Moody, J.R.2
Barnes, I.L.3
Gramlich, J.W.4
Murphy, T.J.5
Paulsen, P.J.6
Shields, W.R.7
-
15
-
-
33749997285
-
Quantitative analysis of trace elements in geological materials by laser ablation ICP-MS: Instrumental operating conditions and calibration values of NIST glasses
-
Norman M.D., Pearson N.J., Sharma A. and Griffin W.L. (1996) Quantitative analysis of trace elements in geological materials by laser ablation ICP-MS: Instrumental operating conditions and calibration values of NIST glasses. Geostandards Newsletter, 20, 247-261.
-
(1996)
Geostandards Newsletter
, vol.20
, pp. 247-261
-
-
Norman, M.D.1
Pearson, N.J.2
Sharma, A.3
Griffin, W.L.4
-
16
-
-
33745153464
-
A compilation of new and published major and trace element data for NIST SRM 610 and SRM 612 partially certified glass reference materials
-
Pearce N.J.G., Perkins W.T., Westgate J.A., Gorton M.P., Jackson S.E., Neal C.R. and Chenety S.P. (1997) A compilation of new and published major and trace element data for NIST SRM 610 and SRM 612 partially certified glass reference materials. Geostandards Newsletter: The Journal of Geostandards and Geoanalysis, 21, 115-144.
-
(1997)
Geostandards Newsletter: The Journal of Geostandards and Geoanalysis
, vol.21
, pp. 115-144
-
-
Pearce, N.J.G.1
Perkins, W.T.2
Westgate, J.A.3
Gorton, M.P.4
Jackson, S.E.5
Neal, C.R.6
Chenety, S.P.7
-
18
-
-
0000867323
-
Chemical characterisation of NIST silicate glass reference material SRM 610 by ICP-MS, TIMS, LIMS, SSMS, INAA, AAS and PIXE
-
Geostandards Newsletter
-
Rocholl A.B.E., Simon K., Jochum K.P., Bruhn F., Gehann R., Kramar U., Luecke W., Molzahn M., Pernicka E., Seufert M., Spettel B. and Stummeier J. (1997) Chemical characterisation of NIST silicate glass reference material SRM 610 by ICP-MS, TIMS, LIMS, SSMS, INAA, AAS and PIXE. Geostandards Newsletter. The Journal of Geostandards and Geoanalysis, 21, 101-114.
-
(1997)
The Journal of Geostandards and Geoanalysis
, vol.21
, pp. 101-114
-
-
Rocholl, A.B.E.1
Simon, K.2
Jochum, K.P.3
Bruhn, F.4
Gehann, R.5
Kramar, U.6
Luecke, W.7
Molzahn, M.8
Pernicka, E.9
Seufert, M.10
Spettel, B.11
Stummeier, J.12
-
19
-
-
0029503689
-
A critical look at quantitative laser ablation ICP-MS analysis of natural and synthetic glasses
-
Stix J., Gauthier G. and Ludden J.N. (1995) A critical look at quantitative laser ablation ICP-MS analysis of natural and synthetic glasses. The Canadian Mineralogist, 33, 435-444.
-
(1995)
The Canadian Mineralogist
, vol.33
, pp. 435-444
-
-
Stix, J.1
Gauthier, G.2
Ludden, J.N.3
-
20
-
-
33745146231
-
Preparation of trace element glass standard reference materials for the National Bureau of Standards
-
Williams J.P. and Erickson A.A. (1971) Preparation of trace element glass standard reference materials for the National Bureau of Standards, Coming Glass Works Report, L-1190, 3pp.
-
(1971)
Coming Glass Works Report
, vol.L-1190
-
-
Williams, J.P.1
Erickson, A.A.2
|