메뉴 건너뛰기




Volumn 46, Issue 2, 1997, Pages 342-346

CCE comparison of ac-dc voltage transfer standards at the lowest attainable level of uncertainty

Author keywords

AC DC transfer; International comparison; Multijunction thermal converters (MJTC); Thermal converters

Indexed keywords

POWER CONVERTERS; SOCIETIES AND INSTITUTIONS; STANDARDS;

EID: 0031121866     PISSN: 00189456     EISSN: None     Source Type: Journal    
DOI: 10.1109/19.571852     Document Type: Article
Times cited : (17)

References (16)
  • 1
    • 0026861884 scopus 로고
    • Standards for AC-DC transfer
    • May
    • B. D. Inglis, "Standards for AC-DC transfer," Metrologia, vol. 29, no. 2, pp. 191-199, May 1992.
    • (1992) Metrologia , vol.29 , Issue.2 , pp. 191-199
    • Inglis, B.D.1
  • 2
    • 0029290490 scopus 로고
    • Current developments in accurate AC-DC transfer measurements
    • Apr.
    • M. Klonz, "Current developments in accurate AC-DC transfer measurements," IEEE Trans. Instrum. Meas., vol. 44, pp. 363-367, Apr. 1995.
    • (1995) IEEE Trans. Instrum. Meas. , vol.44 , pp. 363-367
    • Klonz, M.1
  • 3
    • 0027585389 scopus 로고
    • CCE intercomparison of AC-DC transfer standards
    • Apr.
    • J. P. M. de Vreede, "CCE intercomparison of AC-DC transfer standards," IEEE Trans. Instrum. Meas., vol. 42, pp. 99-108, Apr. 1993.
    • (1993) IEEE Trans. Instrum. Meas. , vol.42 , pp. 99-108
    • De Vreede, J.P.M.1
  • 5
    • 0024646506 scopus 로고
    • High accuracy calculable ac-dc transfer standards for the LF-30 MHz frequency range
    • Apr.
    • M. Nomair and K. J. P. M. Harmans, "High accuracy calculable ac-dc transfer standards for the LF-30 MHz frequency range," IEEE Trans. Instrum. Meas., vol. 38, pp. 342-345, Apr. 1989.
    • (1989) IEEE Trans. Instrum. Meas. , vol.38 , pp. 342-345
    • Nomair, M.1    Harmans, K.J.P.M.2
  • 6
    • 0025436141 scopus 로고
    • AC-DC transfer difference of the PTB-multijunction thermal converter at 1 MHz
    • Ottawa, Ont., Canada, June
    • M. Klonz, "AC-DC transfer difference of the PTB-multijunction thermal converter at 1 MHz," in CPEM'90 Dig., Ottawa, Ont., Canada, June 1990, pp. 60-61.
    • (1990) CPEM'90 Dig. , pp. 60-61
    • Klonz, M.1
  • 7
    • 0026158095 scopus 로고
    • Digital 'bridge' for comparison of AC-DC transfer instruments
    • R. B. D. Knight, D. J. Legg, and P. Martin, "Digital 'bridge' for comparison of AC-DC transfer instruments," Proc. IEEE, vol. 138, pp. 169-175, 1991.
    • (1991) Proc. IEEE , vol.138 , pp. 169-175
    • Knight, R.B.D.1    Legg, D.J.2    Martin, P.3
  • 8
    • 0020098272 scopus 로고
    • Components and systems for AC/DC transfer at the ppm level
    • P. Martin and R. B. D. Knight, "Components and systems for AC/DC transfer at the ppm level," IEEE Trans. Instrum. Meas., vol. 32, pp. 63-72, 1983.
    • (1983) IEEE Trans. Instrum. Meas. , vol.32 , pp. 63-72
    • Martin, P.1    Knight, R.B.D.2
  • 9
    • 0027583255 scopus 로고
    • Flexible system for precision and automatic comparison of ac measuring devices
    • Apr.
    • U. Pogliano, G. C. Bosco, G. La Paglia, and G. Zago, "Flexible system for precision and automatic comparison of ac measuring devices," IEEE Trans. Instrum. Meas., vol. 42, pp. 295-300, Apr. 1993.
    • (1993) IEEE Trans. Instrum. Meas. , vol.42 , pp. 295-300
    • Pogliano, U.1    Bosco, G.C.2    La Paglia, G.3    Zago, G.4
  • 10
    • 84939360851 scopus 로고
    • A dual channel automated comparator for AC-DC difference measurements
    • June
    • E. S. Williams and J. Kinard, "A dual channel automated comparator for AC-DC difference measurements," IEEE Trans. Instrum. Meas., vol. IM-34, pp. 290-294, June 1985.
    • (1985) IEEE Trans. Instrum. Meas. , vol.IM-34 , pp. 290-294
    • Williams, E.S.1    Kinard, J.2
  • 11
    • 0022732921 scopus 로고
    • Multijunction thermal converter as the NBS primary ac-dc standards for as current and voltage measurements
    • June
    • F. L. Hermach, J. R. Kinard, and J. R. Hastings, "Multijunction thermal converter as the NBS primary ac-dc standards for as current and voltage measurements," IEEE Trans. Instrum. Meas., vol. 36, pp. 300-306, June 1987.
    • (1987) IEEE Trans. Instrum. Meas. , vol.36 , pp. 300-306
    • Hermach, F.L.1    Kinard, J.R.2    Hastings, J.R.3
  • 12
    • 0024645840 scopus 로고
    • Determination of the ac-dc difference in the 0.1-100 MHz frequency range
    • Apr.
    • J. R. Kinard and T. X. Cai, "Determination of the ac-dc difference in the 0.1-100 MHz frequency range," IEEE Trans. Instrum. Meas., vol. 38, pp. 360-367, Apr. 1989.
    • (1989) IEEE Trans. Instrum. Meas. , vol.38 , pp. 360-367
    • Kinard, J.R.1    Cai, T.X.2
  • 13
    • 0031121523 scopus 로고    scopus 로고
    • Improvements in the NRC ac-dc transfer capabilities
    • Apr.
    • R. F. Clark and P. S. Filipski, "Improvements in the NRC ac-dc transfer capabilities," IEEE Trans. Instrum. Meas., vol. 46, Apr. 1997.
    • (1997) IEEE Trans. Instrum. Meas. , vol.46
    • Clark, R.F.1    Filipski, P.S.2
  • 16
    • 33747950437 scopus 로고
    • Metrologia, vol. 17, p. 73, 1981.
    • (1981) Metrologia , vol.17 , pp. 73


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.