메뉴 건너뛰기




Volumn 51, Issue 1, 1997, Pages

Time-of-flight mass spectrometry for elemental analysis

Author keywords

[No Author keywords available]

Indexed keywords


EID: 0002475393     PISSN: 00037028     EISSN: None     Source Type: Journal    
DOI: 10.1366/0003702971938759     Document Type: Article
Times cited : (92)

References (71)
  • 14
    • 5944221633 scopus 로고    scopus 로고
    • The Design and Characteristics of a Plasma Source Mass Spectrograph
    • paper in press
    • T. W. Burgoyne, G. M. Hieftje, and R. A. Hites, "The Design and Characteristics of a Plasma Source Mass Spectrograph", J. Am. Soc. Mass Spectrom. (1996), paper in press.
    • (1996) J. Am. Soc. Mass Spectrom.
    • Burgoyne, T.W.1    Hieftje, G.M.2    Hites, R.A.3
  • 24
    • 5944254587 scopus 로고    scopus 로고
    • Selective Elimination of Argon Ions in an Inductively Coupled Plasma-Ion Trap Mass Spectrometer
    • Portland, Oregon WPC 55
    • G. Eiden, C. Barinaga, and D. Koppenaal, "Selective Elimination of Argon Ions in an Inductively Coupled Plasma-Ion Trap Mass Spectrometer", presented at the 44th ASMS Conference on Mass Spectrometry and Allied Topics, Portland, Oregon (1996), WPC 55.
    • (1996) 44th ASMS Conference on Mass Spectrometry and Allied Topics
    • Eiden, G.1    Barinaga, C.2    Koppenaal, D.3
  • 40
    • 5944253278 scopus 로고    scopus 로고
    • Atomic MS of Solids by Use of a Microsecond Pulse Discharge and a TOF Mass Analyzer
    • Portland, Oregon MOB 09:30
    • W. W. Harrison, "Atomic MS of Solids By Use of a Microsecond Pulse Discharge and a TOF Mass Analyzer", presented at the 44th ASMS Conference on Mass Spectrometry and Allied Topics, Portland, Oregon (1996). MOB 09:30.
    • (1996) 44th ASMS Conference on Mass Spectrometry and Allied Topics
    • Harrison, W.W.1
  • 63
    • 5944247025 scopus 로고    scopus 로고
    • Continuum Background Reduction in Time-of-Flight Mass Spectrometry with Continuous Ion Sources
    • paper in press
    • P. P. Mahoney, G. Li, S. J. Ray, and G. M. Hieftje, "Continuum Background Reduction in Time-of-Flight Mass Spectrometry with Continuous Ion Sources", J. Am. Soc. Mass Spectrom. (1996), paper in press.
    • (1996) J. Am. Soc. Mass Spectrom.
    • Mahoney, P.P.1    Li, G.2    Ray, S.J.3    Hieftje, G.M.4
  • 67
    • 0542364875 scopus 로고    scopus 로고
    • Electrothermal Vaporization Inductively Coupled Plasma Mass Spectrometry with a Time-of-Flight Mass Analyzer
    • submitted
    • P. P. Mahoney, S. J. Ray, G. Li, and G. M. Hieftje, "Electrothermal Vaporization Inductively Coupled Plasma Mass Spectrometry with a Time-of-Flight Mass Analyzer", Anal. Chem., submitted (1996).
    • (1996) Anal. Chem.
    • Mahoney, P.P.1    Ray, S.J.2    Li, G.3    Hieftje, G.M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.