-
1
-
-
0039402339
-
High resolution portable XRF mercury di-iodide spectrometer for field screening of hazardous metal wastes
-
Bernick M., Berry P.F., Voots G.R., Prince G., Ashe J.B., Patel J. and Gupta P. (1992) High resolution portable XRF mercury di-iodide spectrometer for field screening of hazardous metal wastes. Advances in X-ray Analysis, 35B, 1047-1053.
-
(1992)
Advances in X-ray Analysis
, vol.35 B
, pp. 1047-1053
-
-
Bernick, M.1
Berry, P.F.2
Voots, G.R.3
Prince, G.4
Ashe, J.B.5
Patel, J.6
Gupta, P.7
-
3
-
-
44049110182
-
Use of a mercury iodide detector for X-ray fluorescence analysis in archaeometry
-
Cesareo R., Gigante G.E., Iwanczyk J.S. and Dabrowski A. (1992) Use of a mercury iodide detector for X-ray fluorescence analysis in archaeometry. Nuclear Instruments and Methods in Physics Research, Section A, 322, 583-590.
-
(1992)
Nuclear Instruments and Methods in Physics Research, Section A
, vol.322
, pp. 583-590
-
-
Cesareo, R.1
Gigante, G.E.2
Iwanczyk, J.S.3
Dabrowski, A.4
-
4
-
-
84980189454
-
High precision non-destructive X-ray fluorescence method applicable to establishing provenance of obsidian artefacts
-
Giauque R.D., Asaro F., Stross F.H. and Hester H.R. (1993) High precision non-destructive X-ray fluorescence method applicable to establishing provenance of obsidian artefacts. X-ray Spectrometry, 22, 44-53.
-
(1993)
X-ray Spectrometry
, vol.22
, pp. 44-53
-
-
Giauque, R.D.1
Asaro, F.2
Stross, F.H.3
Hester, H.R.4
-
5
-
-
31144458591
-
Evaluation of portable X-ray fluorescence spectrometer for measurement of lead in paint, soil and dust
-
Hardison D.L., Whittaker C.O., Neefus J.N., Estes E.D. and Gutnecht W.F. (1993) Evaluation of portable X-ray fluorescence spectrometer for measurement of lead in paint, soil and dust. US Environment Protection Agency Report EPA/600/A-92/245, 11pp.
-
(1993)
US Environment Protection Agency Report
, vol.EPA-600-A-92-245
-
-
Hardison, D.L.1
Whittaker, C.O.2
Neefus, J.N.3
Estes, E.D.4
Gutnecht, W.F.5
-
6
-
-
33745120909
-
X-ray fluorescence survey of lead contaminated residential soils in Leadville, Colorado: A case study
-
EPA/600/R-93/073
-
Kuharic C.A., Cole W.H., Singh A.K. and Gonzales D. (1993) X-ray fluorescence survey of lead contaminated residential soils in Leadville, Colorado: A case study. US Environment Protection Agency Report, EPA/600/R-93/073.
-
(1993)
US Environment Protection Agency Report
-
-
Kuharic, C.A.1
Cole, W.H.2
Singh, A.K.3
Gonzales, D.4
-
7
-
-
0042544879
-
Non-destructive analysis of Venezuelan artefacts of different sizes and shapes for provenancing studies
-
LeBrecque J.J., Resales P.A. and Carias O. (1991) Non-destructive analysis of Venezuelan artefacts of different sizes and shapes for provenancing studies. Advances in X-ray Analysis, 34, 307-312.
-
(1991)
Advances in X-ray Analysis
, vol.34
, pp. 307-312
-
-
LeBrecque, J.J.1
Resales, P.A.2
Carias, O.3
-
9
-
-
84980139774
-
Laser argon dating and geological provenancing of a stone axe from the Stonehenge environs
-
Kelley S., Williams-Thorpe O. and Thorpe R.S. (1994) Laser argon dating and geological provenancing of a stone axe from the Stonehenge environs. Archaeometry, 36, 209-216.
-
(1994)
Archaeometry
, vol.36
, pp. 209-216
-
-
Kelley, S.1
Williams-Thorpe, O.2
Thorpe, R.S.3
-
10
-
-
84905275058
-
-
Lide D.R. (Editor-in-chief) CRC Press (Baton Rouge), Table 10
-
Lide D.R. (Editor-in-chief) (1994) CRC handbook of chemistry and physics (75th). CRC Press (Baton Rouge), Table 10, p283.
-
(1994)
CRC Handbook of Chemistry and Physics (75th)
, pp. 283
-
-
-
11
-
-
84974239997
-
Mons Claudianus and the problem of the "Granito del foro": A geological and geochemical approach
-
Peacock D.P.S. ; Williams-Thorpe O., Thorpe R.S. and Tindle A.G. (1994) Mons Claudianus and the problem of the "Granito del foro": A geological and geochemical approach. Antiquity, 68, 209-230.
-
(1994)
Antiquity
, vol.68
, pp. 209-230
-
-
Peacock, D.P.S.1
Williams-Thorpe, O.2
Thorpe, R.S.3
Tindle, A.G.4
-
13
-
-
0031176976
-
Investigation of a correction procedure for surface irregularity effects based on scatter peak intensities in the field analysis of geological and archaeological rock samples by portable X-ray fluorescence spectrometry
-
in press
-
Potts P.J., Webb P.C. and Williams-Thorpe O. (1997) Investigation of a correction procedure for surface irregularity effects based on scatter peak intensities in the field analysis of geological and archaeological rock samples by portable X-ray fluorescence spectrometry. Journal of Analytical Atomic Spectrometry (in press).
-
(1997)
Journal of Analytical Atomic Spectrometry
-
-
Potts, P.J.1
Webb, P.C.2
Williams-Thorpe, O.3
-
14
-
-
0001675618
-
Analysis of silicate rocks using field-portable X-ray fluorescence instrumentation incorporating a mercury (II) iodide detector: Preliminary assessment of analytical performance
-
Potts P.J., Williams-Thorpe O. and Webb P.C. (1995) Analysis of silicate rocks using field-portable X-ray fluorescence instrumentation incorporating a mercury (II) iodide detector: preliminary assessment of analytical performance. Analyst, 120, 1273-1278.
-
(1995)
Analyst
, vol.120
, pp. 1273-1278
-
-
Potts, P.J.1
Williams-Thorpe, O.2
Webb, P.C.3
-
16
-
-
85005558635
-
Characterisation of chromium-contaminated soils using field-portable X-ray fluorescence
-
Puls R.W., Clark D.A., Carlson C. and Vardy J. (1994) Characterisation of chromium-contaminated soils using field-portable X-ray fluorescence. Ground Water Monitoring and Remediation, 14, 111-115.
-
(1994)
Ground Water Monitoring and Remediation
, vol.14
, pp. 111-115
-
-
Puls, R.W.1
Clark, D.A.2
Carlson, C.3
Vardy, J.4
|