Volumn 0, Issue 0, 1998, Pages 21-24

Identification of ventricular tachycardias by means of fast wavelet analysis

Author keywords

[No Author keywords available]

Indexed keywords


EID: 0001921144     PISSN: 02766574     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Article
Times cited : (5)

References (8)
  • 1
    • 0006918490 scopus 로고    scopus 로고
    • Improved survival with an implanted defibrillator in patients with coronary disease at risk for ventricular arrhythmia
    • Moss A, Hall J, Cannom DS, et al. Improved survival with an implanted defibrillator in patients with coronary disease at risk for ventricular arrhythmia. N Engl J Med 1996;335:1933-40.
    • (1996) N Engl J Med , vol.335 , pp. 1933-1940
    • Moss, A.1    Hall, J.2    Cannom, D.S.3
  • 2
    • 9844224486 scopus 로고    scopus 로고
    • A comparison of antiarrhythmic drug therapy with implantable defibrillators in patients resuscitated from near fatal ventricular arrhythmias
    • The Antiarrhythmics Versus Implantable Defibrillators (AVID) Investigators. A comparison of antiarrhythmic drug therapy with implantable defibrillators in patients resuscitated from near fatal ventricular arrhythmias. N Engl J Med 1997;337:1576-83.
    • (1997) N Engl J Med , vol.337 , pp. 1576-1583
  • 3
    • 0026448128 scopus 로고
    • Electrocardiographically documented unnecessary, spontaneous shocks in 214 patients with implantable cardioverter defibrillators
    • Grimm W, Flores WF, Marchlinksi FE. Electrocardiographically documented unnecessary, spontaneous shocks in 214 patients with implantable cardioverter defibrillators. PACE 1992;15:1667-73.
    • (1992) PACE , vol.15 , pp. 1667-1673
    • Grimm, W.1    Flores, W.F.2    Marchlinksi, F.E.3
  • 4
    • 0002473299 scopus 로고
    • Stored electrograms in cardioverter-defibrillator therapy: Accuracy of rhythm diagnosis in 335 spontaneous arrhythmia episodes
    • Neuzner J, Pitschner HF, König S, et al. Stored electrograms in cardioverter-defibrillator therapy: accuracy of rhythm diagnosis in 335 spontaneous arrhythmia episodes. J Ambul Monitor 1995;88:1-9.
    • (1995) J Ambul Monitor , vol.88 , pp. 1-9
    • Neuzner, J.1    Pitschner, H.F.2    König, S.3
  • 5
    • 0031025636 scopus 로고    scopus 로고
    • Preliminary clinical experience with the first dual chamber pacemaker defibrillator
    • Lavergne T, Daubert JC, Chauvin M, et al. Preliminary clinical experience with the first dual chamber pacemaker defibrillator. PACE 1997;20 (Pt. II): 182-5.
    • (1997) PACE , vol.20 , Issue.2 PART , pp. 182-185
    • Lavergne, T.1    Daubert, J.C.2    Chauvin, M.3
  • 6
    • 0024904699 scopus 로고
    • Multifrequency channel decomposition of images and wavelet models
    • Mallat S. Multifrequency channel decomposition of images and wavelet models. IEEE Trans Acoust Speech Signal Processing 1989;12:2091-2110.
    • (1989) IEEE Trans Acoust Speech Signal Processing , vol.12 , pp. 2091-2110
    • Mallat, S.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.